6

Alpha InTec C, X and GS

Error

code

Fault

Fault description

Possible causes

Check flame sensing electrode and lead
PCB fault

Check for jammed control panel buttons
Check for jammed PCB buttons

Air in heat exchanger
Blocked or restricted primary flow
Heat exchanger air flow blocked
Flue restriction
Flue sensor fault
Pump fault
Boiler or heating circuit valve closed

Blocked or restricted primary flow
Air in heat exchanger
Boiler or heating circuit valve closed
Pump fault
Primary flow sensor fault

Check sensor wiring connection
Flue sensor faulty

Remote control or receiver connection wiring
Remote control or receiver

Check mains power supply

Check flame sensing electrode and lead
Check for flue gas recirculation
Check/adjust the gas valve settings
Check/adjust the fan speed settings

Check gas supply/working pressure
Check flame sensing electrode and lead
Check for flue gas recirculation
Check/adjust the gas valve settings
Check/adjust the fan speed settings

Check external control (room thermostat)
requests
Rapid on/off hot tap requests

Check external sensor and cable are not
damaged or wet
Check continuity of external sensor and circuit
Check connection at X19 on PCB and sensor
connecting block

Air in heat exchanger
Restricted primary flow
Heat exchanger air flow blocked
Flue restriction
Flue sensor fault
Pump fault

Batteries require replacing
Distance between boiler and climatic control
too great
Interference
Object blocking signal (metallic)

False flame detection
Flame detected but gas valve is not open

Control panel button stuck in the on position

Rapid temperature rise of flue sensor

Rapid temperature rise of primary sensor

Flue sensor resistance out of range

Loss of connection between the boiler and
Alpha Climatic control unit

Insufficient supply voltage to operate boiler

Flame detected but signal is lost. Ignition
reattempts after fan purge

Repeated loss of flame signal during operation
(shown as E38 in the fault code history in the
INFO menu)

The boiler has attempted to fire repeatedly for
the maximum time limit

No continuity of external sensor circuit

Flue thermostat has sensed high flue gas
temperature (110°C) and reduced the burner 
output to prevent damage. If the temperature
continues to rise the boiler will lock out and E03
will be displayed

Error between the communication of the
Climatic transmitter and boiler receiver

Flame sensing fault

Control panel button
fault

Overheat lock out

Insufficient primary
flow

Flue sensor fault

Loss of
communication with
external control
(Alpha Climatic)

Low supply voltage

Loss of flame
rectification

Loss of flame
rectification

Safety lock out

External sensor
intervention

Reduced burner
output

Climatic RF
communication fault

20

24

25

27

29

31

37

38

43

44

46

47

51

Содержание 24X

Страница 1: ...ciency Condensing Combination Boilers British Gas Service Listed For use with Natural Gas or Propane Gas AS SUPPLIED Leave these instructions with the User 0051 Nepicar House London Road Wrotham Heath...

Страница 2: ...ve any air that may be trapped in the heating system If the boiler has already been commissioned by the installer then this operation can be terminated by pressing the reset button item 3 in Fig 1 Not...

Страница 3: ...vate even if requested by external controls frost protection and pump cycle are still active Winter setting The boiler will operate in both heating and hot water The heating will activate depending on...

Страница 4: ...C the boiler will fire in heating mode and raise the temperature of the heating water in the boiler only to 30 C For this function to be active the gas and electricity supplies to the boiler must be t...

Страница 5: ...iction Flue sensor fault Gas valve lead connection fault Faulty gas valve Faulty PCB Flow sensor wire connections Flow sensor faulty DHW sensor wiring connection DHW sensor faulty Refer to fault histo...

Страница 6: ...ir flow blocked Flue restriction Flue sensor fault Pump fault Batteries require replacing Distance between boiler and climatic control too great Interference Object blocking signal metallic False flam...

Страница 7: ...871 8764 7 GAS LEAK If a fault or gas leak is suspected turn off the gas supply Do not touch any electrical switches do not smoke and extinguish all naked flames Contact your local Gas Region immediat...

Страница 8: ...ols available on the market However to get the most comfort and efficiency from your boiler we recommend the Alpha Climatic controls with enhanced remote boiler functions and efficiency control Please...

Отзывы: