10  GAS SAFETY REGULATIONS

1.  BOILER LOCATION

Always ensure the following clearances are available around the casing of the boiler:-
 

Top: 

(horizontal flue) 235 mm, 

Top:

 (vertical flue) 150 mm, 

Bottom: 

150 mm, 

Bottom: 

(C or X with Jig) 250 mm,

 

Each side:

 5 mm, 

Front: 

450 mm

Do not store any other articles in a cupboard containing the boiler and never place any clothing or combustible material on or 
near the boiler or flue pipe.

2.  FLUE TERMINAL

The terminal on the outside wall must not be allowed to be obstructed. If it is damaged, in any way, turn the boiler off and 
contact your Service Engineer.

Note: 

The Alpha InTec boilers are high efficiency condensing boilers and when operating vapour will be emitted from the 

terminal. This is safe and quite normal.

3.  MAINS FAILURE

In the event of an electrical supply failure the boiler will not operate. When the supply is restored, the boiler will return to 
normal operation. Remember to reset any controls, if fitted, when the supply is restored.
If the mains water supply fails, there will be no hot water from the taps. The boiler will continue to provide central heating.

4.  ADDITIONAL BATHROOM FITTINGS

Any equipment such as mixing valves, showers, bidets etc. must be designed to operate at mains water pressure. Contact 
your plumbing merchant or installer for advice when considering purchasing such items.

5.  CLEANING

Use only a damp cloth and mild detergent to clean the boiler outer casing. Do not use abrasive cleaners.

6.  SERVICING

To maintain efficient and safe operation of your boiler, routine annual servicing is essential.
For advice on servicing contact:- The Alpha Helpline: 0844 871 8764.

7.  GAS LEAK

If a fault or gas leak is suspected, turn off the gas supply. Do not touch any electrical switches, do not smoke and extinguish 
all naked flames. Contact your local Gas Region immediately on 0800 111 999.

8.  ELECTRICAL SUPPLY

The boiler requires a 230/240 V ~ 50 Hz supply, fused at 3 A if a 13 A 3-pin plug is used or a 5 A fuse if any other type of 
plug is used.

To connect a plug:-

The colour of the wires in the mains lead of the boiler may not correspond with the coloured markings identifying the 
terminals in your plug. In this case proceed as follows:-
The wire coloured green and yellow must be connected to the terminal in the plug that is marked with the letter 

E

, or by the 

earth symbol 

, or coloured green or green and yellow.

The blue wire must be connected to the terminal which is marked with either the letter 

N

 or coloured black.

The brown wire must be connected to the terminal which is marked with the letter 

L

 or coloured red.

THE APPLIANCE MUST BE EARTHED.

9  IMPORTANT NOTES

Current Gas Safety (Installation and Use) Regulations:-
It is the law that all gas appliances are installed and serviced by a competent person, i.e. Gas Safe registered personnel. 
Failure to install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure 
compliance with the law. The manufacturer's instructions must not be taken in any way as over-riding statutory obligations.
The Benchmark Checklist must be fully completed by the installer on installation of the boiler. The Benchmark Checklist is 
shown in back of the Installation and Servicing instructions. All Gas Safe registered installers carry a Gas Safe ID card and 
have a registration number. Both should be recorded in the Checklist. You can check your installer is Gas Safe registered by 
calling Gas Safe on 0800 408 5500.

Содержание 24X

Страница 1: ...ciency Condensing Combination Boilers British Gas Service Listed For use with Natural Gas or Propane Gas AS SUPPLIED Leave these instructions with the User 0051 Nepicar House London Road Wrotham Heath...

Страница 2: ...ve any air that may be trapped in the heating system If the boiler has already been commissioned by the installer then this operation can be terminated by pressing the reset button item 3 in Fig 1 Not...

Страница 3: ...vate even if requested by external controls frost protection and pump cycle are still active Winter setting The boiler will operate in both heating and hot water The heating will activate depending on...

Страница 4: ...C the boiler will fire in heating mode and raise the temperature of the heating water in the boiler only to 30 C For this function to be active the gas and electricity supplies to the boiler must be t...

Страница 5: ...iction Flue sensor fault Gas valve lead connection fault Faulty gas valve Faulty PCB Flow sensor wire connections Flow sensor faulty DHW sensor wiring connection DHW sensor faulty Refer to fault histo...

Страница 6: ...ir flow blocked Flue restriction Flue sensor fault Pump fault Batteries require replacing Distance between boiler and climatic control too great Interference Object blocking signal metallic False flam...

Страница 7: ...871 8764 7 GAS LEAK If a fault or gas leak is suspected turn off the gas supply Do not touch any electrical switches do not smoke and extinguish all naked flames Contact your local Gas Region immediat...

Страница 8: ...ols available on the market However to get the most comfort and efficiency from your boiler we recommend the Alpha Climatic controls with enhanced remote boiler functions and efficiency control Please...

Отзывы: