8
I
10. MALFUNCTION AND TROUBLESHOOTING
Make sure that the vacuum cleaner is always switched off and disconnected from the mains for repair.
Malfunctions are not always due to defects in the vacuum cleaner.
Malfunction
Cause
Remedial action
Decrease in vacuuming power
Filter dirty
Close the vacuum connection with the sealing
plug and switch on the vacuum cleaner again and
wait for the cleaning cycle to clean the filter.
Filter bag full
Change
Container full
Empty
Nozzle, pipes or hose clogged
Clean
Container nozzle / filter bag flange clogged
Clean
Vacuum cleaner does not start
Mains plug not plugged in
Plug in the mains plug
No mains power
Check fuse
Connection cable defective
Renew
Water sensor switched off
Empty container and clean electrodes
Vacuum cleaner switched to "Auto"
see "5. Switching on the vacuum cleaner"
Vacuum cleaner does not start when the
tool is switched on in "Auto" mode
Power tool not plugged into socket on vacuum
cleaner
Insert the mains plug into the socket on the
vacuum cleaner
Tool does not reach the minimum power of 20 W to be
recognised by the vacuum cleaner.
Use the vacuum cleaner in continuous operation
Waste Bag is vacuumed onto the filter
Waste Bag is not inserted and fitted correctly.
Place the Waste Bag completely over the edge
of the container and press the flange completely
over the receptacle and put the holes provided
over the electrodes of the water shut-off.
Vacuum cleaner: with filter bag inserted,
dust in the container
Filter bag not fitted correctly.
Press the filter bag completely over the filter bag
flange.
Further accessories can be found in the spare parts drawing.
11.
ORIGINAL ACCESSORIES
Article designation
Special features
Item no.
Filter
HEPA 13
118175
Fleece filter bags (packing unit = 5 pcs.)
102066
Optional
Item no.
Waste Bag (packing unit = 5 pcs.)
118138