1.1.25. The UPS is intended for installation in a controlled environment.
1.1.26. CAUTION: A disconnect switch must be provided by others for the AC
output circuit. To reduce the risk of fire connect only to a circuit provided
with branch circuit over-current protection for 30 amperes for 6 kVA rating
in accordance with the National Electric Code, ANSI/NFPA 70.
1.1.27. CAUTION: To reduce the risk of fire connect the UPS only to a circuit
provided with branch circuit over-current protection for 40 amperes for 6
kVA rating in accordance with the National Electric Code, ANSI/NFPA 70.
1.1.28. Install the UPS so that it is not likely to be contacted by people.
1.1.29. The maximum ambient operating temperature is 40
°
C or equivalent.
1.1.30. Units are considered acceptable for use in a maximum ambient 40°C
1.1.31. CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN
INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO
THE INSTRUCTIONS.
1.1.32. CAUTION - Do not dispose of batteries in a fire. The batteries may
explode.
1.1.33. CAUTION – Do not open or mutilate batteries. Released electrolyte is
harmful to the skin and eyes. It may be toxic.
1.1.34. CAUTION– A battery can present a risk of electrical shock and high short
circuit current. The following precautions should be observed when
working on batteries:
1)
Remove watches, rings, or other metal objects.
2)
Use tools with insulated handles.
3)
Wear rubber gloves and boots.
4)
Do not lay tools or metal parts on top of batteries.
5)
Disconnect charging source prior to connecting or disconnecting battery
terminals.
6)
Determine if battery is inadvertently grounded. If inadvertently grounded,
remove source from ground. Contact with any part of a grounded battery
can result in electrical shock. The likelihood of such shock can be
reduced if such grounds are removed during installation and
maintenance (applicable to equipment and remote battery supplies not
having a grounded supply circuit).
1.1.35. UPS can be used with only one Battery Cabinet
1.2. Battery Care
If the UPS is unused for an extended period of time it must be stored in a
moderate climate. The batteries should be charged for twelve hours every
three months by plugging the UPS power cord into a wall receptacle and
turning on the input breaker on the front panel. Repeat this procedure every
two months under a high-temperature environment.
1.1.22. The UPS offers a CVCF (Constant Voltage Constant Frequency) setting
function.
a. For correct setting and wiring please contact with your local utility
agent.
b. Do not set it yourself or your warranty will be void.
1.1.23. This UPS has been designed and constructed to protect your assets from
the wide range of power aberrations experienced on utility power lines
today. It is your insurance for a reliable, clean and stable voltage supply. It
is worth taking care to install the system correctly and to have it
maintained correctly by your local dealer.
1.1.24. SAVE THESE INSTRUCTIONS. This manual contains important
instructions that should be followed during installation and maintenance of
the UPS and batteries.