22
Subject to technical amendments without prior notice | 83072100aUK | ait-deutschland GmbH
11 Maintenance
NOTE
We recommend that you sign a maintenance
agreement with an accredited heating
company.
11.1 Basic principles
The cooling circuit of the heat pump requires no
regular maintenance.
Local regulations – e.g. EU Regulation (EC) 517/2014 –
among other things, require leak checks beforehand
and/or for a logbook to be kept for certain heat pumps.
The hermetic tightness and refrigerant fill quantity are
criteria for whether a logbook has to be kept and leak
tests performed or not, and at what time intervals.
►
Ensure compliance with local regulations with
regard to the specific heat pump system.
11.2 Maintenance as required
● Checking and cleaning the components of the
heating circuit and the heat source, e.g. valves,
expansion vessels, circulation pumps, filters, dirt
traps
● Checking the function of the safety valve (on site)
for the domestic hot water tank and the safety
valve for the heating circuit
11.3
Clean and flush the evaporator
and condenser
► Clean and flush the evaporator/condenser strictly
according to the manufacturer's regulations.
► After flushing the evaporator/condenser with
chemical cleaning product: neutralise any
residues and flush the evaporator/condenser
thoroughly with water.
11.4 Yearly maintenance
►
Record the quality of the heating water analytically.
In case of deviations from the specifications, take
suitable measures without delay.
12 Faults
►
Read out the cause of the fault via the diagnostics
program of the heating and heat pump controller.
►
Contact the local partner of the manufacturer or
the factory's customer service. Have the fault
message and unit number (
“Unit sticker”,
page 3) to hand.
12.1
Unlock the safety temperature
limiter
A safety temperature limiter is installed in the electric
heating element. If the heat pump fails or there is air in
the system:
► Check whether the Reset button
(②)
of the safe-
ty temperature limiter
(①)
has jumped out (by ap
-
prox. 2 mm).
1
2
►
Press the reset button
(②)
back in again.
►
If the safety temperature limiter trips again, con-
tact the local partner of the manufacturer or the
factory‘s customer service.
Содержание WZSV 42K3M
Страница 1: ...UK 83072100aUK Brine Water Heat Pumps Brine heat station Operating Manual WZSV 42K3M...
Страница 31: ...31 Subject to technical amendments without prior notice 83072100aUK ait deutschland GmbH...
Страница 39: ...39 Subject to technical amendments without prior notice 83072100aUK ait deutschland GmbH...