20
Subject to change without notice | 83054200hUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Electrical connections
Observe the following when performing all work:
DANGER
Danger of fatal injury due to electric
current!
Electrical connections may be installed
only by qualified electricians.
Before opening the unit, disconnect the
system from the power supply and secure
it from being switched back on!
WARNING
Observe the relevant EN, VDE and/or ap-
plicable local safety regulations during the
installation and during all electrical work.
Comply with technical connection re-
quirements of the responsible power sup-
ply company (if required by the latter)!
POWER CONNECTION
It is not necessary to open the electric switch cabinet in
order to connect the power to the heat pump. The pow-
er is connected at the connection boxes on the water
connection side.
If the unit is closed, open facing panels…
“Preparing for installation”
Open connection boxes…
LW 71… / LW 81…:
1 Connection box for electric
heating element
2 Connection box for compressor
Hot-water tank
If the heat pump will be used for heating hot water, you
must integrate special hot-water tanks in the heat pump
system. The storage volume must be sufficient so that
the required hot water quantity is available even during
a power outage.
NOTICE
The heat exchanger surface of the hot water
tank must be dimensioned so that the heating
capacity of the heat pump is transferred with
minimal spreading.
We offer a variety of hot-water tanks for you to choose
from. They are optimized for use with your heat pump.
NOTICE
Integrate the hot-water tank in the heat pump
system corresponding to the hydraulic diagram
for your system.