NOTICE.
If the wall duct is positioned above ground level,
attach the weather guard.
If the wall duct is positioned in a light well (be-
low ground level), attach the rain guard.
Repeat – the process on the air output side.
INSTALLATION / CONNECTION TO HEATING CIRCUIT
DANGER!
Danger of fatal injury due to electric
shock!
Before opening the unit, disconnect the
system from the power supply and secure
it from being switched back on!
ATTENTION
Connect the unit to the heating circuit accord-
ing to the hydraulic diagram for the respective
model.
“Hydraulic connection” instructions.
NOTICE.
Check to make sure that the diameters and
lengths of the pipes for the heating circuit are
sufficiently dimensioned.
NOTICE.
Circulating pumps must be multi-stage. They
must be able to deliver at least the minimum hot
water flow rate required for your model.
WIRE MESH GRILLE AND WEATHER / RAIN GUARDS
ASSEMBLY
Proceed as follows:
Remove the wire mesh grille and the weather / rain
guards as well as the assembly frame and fastening
material from their respective boxes…
From the outside of the house inwards, insert the
assembly frame into the wall duct on the air intake
side and secure with screws…
8 x
Position the wire mesh grille in the assembly
frame…
Set the weather / rain guards on the assembly frame
in the wall duct and screw down…