13
We reserve the right to modify technical specifications without prior notice.
83054300dUK
© ait-deutschland GmbH
Repeat – the process on the air output side.
NOTICE.
Don't forget:
After the air ducts have been secured to the
heat pump, close the opening between the wall
duct and the air duct using the bentonite water-
stop tape included with delivery.
NOTICE.
Secure the air ducts to the cover using appropri-
ate measures.
SCREEN FRAME ASSEMBLY
Screw the screen frame to the wall ducts on both the air
intake and output sides.
NOTICE.
The screen frame has no function, it is included
solely to provide an optically attractive transi-
tion to the wall duct.
1 Wall duct
2 Air duct
3 Roll seal
4 Bentonite waterproofing tape
(apply only after assembling the
unit's connection fastener)
NOTICE.
After the other end of the air duct has been se-
cured to the heat pump, close the opening be-
tween the wall duct and the air duct using the
bentonite waterstop tape included with delivery.
SECURING THE AIR DUCT ON THE HEAT PUMP
Proceed as follows:
Clip on the assembly rail and secure it using special
screws to the spots on the air duct designated as
the air intake side…
Stick the adapter base included with delivery on the
edge of the air duct…
Position the air duct on the respective opening of
the air intake side…
Hook the tension springs included with delivery
into the holes provided for them on the air intake
side of heat pump 4…
Hook the tension springs into the assembly tail that
has been screwed on to the air duct…
Secure a protective cap over the assembly rail…