Chapter III Introduction to System 5
4
Isolation transformer
1 set
5
Power Management Unit
1 set
It is installed in the cabinet door.
3.2
Technical parameters
Table 3-2 is detailed parameters for Bi-directional Hybrid Storage Inverter.
Table 3-2 Technical parameters
parameters
PWG2-50K
PWG2-100K
PV input quantities:
Vmax PV
900 d.c. V
900 d.c. V
PV input operating voltage range
520~900
d.c. V
520~900
d.c. V
Maximum operating PV input current
192
d.c. A
384
d.c. A
Isc PV
225 d.c. A
450
d.c. A
Max inverter backfeed current to the array
5A
5A
a.c. output quantities
Voltage (nominal)
400 a.c. V
400 a.c. V
Current (maximum continuous)
72 a.c. A
144 a.c. A
Current (inrush)
86 a.c. A
172 a.c. A
Frequency (nominal)
50/60 Hz
50/60 Hz
Power (maximum continuous)
50000 W
100000 W
Power factor range
±0.8
±0.8
Maximum output fault current
200 a.c. A
400 a.c. A
Maximum output overcurrent protection
86 a.c. A
172 a.c. A
a.c. input quantities
Voltage (nominal)
400 a.c. V
400 a.c. V
Current (maximum continuous)
151 a.c. A
303 a.c. A
Current (inrush)
181 a.c. A
363 a.c. A
Frequency
50/60 Hz
50/60 Hz
d.c. input (other than PV) quantities
Voltage (range)
250~520
d.c. V
250~520
d.c. V
Nominal battery voltage
450 d.c. V
450 d.c. V
Current (maximum continuous)
130 d.c. A
260 d.c. A
d.c. output quantities
Voltage
250~520
d.c. V
250~520
d.c. V
Nominal battery voltage
450 d.c. V
450 d.c. V
Current (maximum continuous)
130 d.c. A
260 d.c. A