23
Continued from previous page.
SPECIAL CODES
ART4LITE/G2 MONITOR
Configuration of the remote activation button
(Door panel ). (Configure only on the master monitor).
Relay1
2
Factory setting
Delay
From
1400
(0
.
5s)
to
1419
(10s)
1403 (2s)
Configuration of the remote activation button
(Door panel ). (Configure only on the master monitor).
Relay2
2
Factory setting
Delay
5
From
1500
(0
.
5s)
to
1519
(10s)
1 03 (2s)
LED lights for night viewing (Door panel ) during a call or communication process. (Configure only on the
3
master monitor).
Automatic
OFF
Always ON
Always
Factory setting
2450
2451
2452
2450 (automatic)
.
Activation times of the outputs (Door panel ). (Configure only on the master monitor).
3
Factory setting
Relay 1
2205 (3s)
Rel
2305 (3s)
ay 2
From
2200
(0
.
5s)
to
2219
(10s)
From
2300
(0
.
5s)
to
2319
(10s)
Configuration of the remote activation button
(Door panel ). (Configure only on the master monitor).
Relay1
3
Factory setting
Delay
From
2400
(0
.
5s)
to
2419
(10s)
2403 (2s)
Configuration of the remote activation button
(Door panel ). (Configure only on the master monitor).
Relay2
3
Factory setting
Delay
5
From
2500
(0
.
5s)
to
2519
(10s)
2 03 (2s)
LED lights for night viewing (Door panel ) during a call or communication process. (Configure only on the
4
master monitor).
Automatic
OFF
Always ON
Always
Factory setting
3450
3451
3452
3450 (automatic)
.
Activation times of the outputs (Door panel ). (Configure only on the master monitor).
4
Factory setting
Relay 1
3205 (3s)
Rel
3305 (3s)
ay 2
From
3200
(0
.
5s)
to
3219
(10s)
From
3300
(0
.
5s)
to
3319
(10s)
Configuration of the remote activation button
(Door panel ). (Configure only on the master monitor).
Relay1
4
Factory setting
Delay
From
3400
(0
.
5s)
to
3419
(10s)
3403 (2s)
Configuration of the remote activation button
(Door panel ). (Configure only on the master monitor).
Relay2
4
Factory setting
Delay
5
From
3500
(0
.
5s)
to
3519
(10s)
3 03 (2s)
To define the light up duration time from 1 to 99 seconds (SAR-G2+ Relay). (
).
Configure only on the master monitor
Factory setting
From 1801 (1s) to 1899 (99s)
1803 (3s)
To define the light up delay time from 0 to 99 seconds (SAR-G2+ Relay). (
).
Configure only on the master monitor
Factory setting
From 1900 (0s) to 1999 (99s)
1900 (0s)
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
Continued overleaf