7. Exhaust of stale air

In the premises where gas appliances are installed it may be
necessary, in addition to the inlet of comburent air, to the ex-
haust of stale air, with consequent inlet of another equal quan-
tity of clean air (fig. 6).
If the exhaust of the stale air occurs with a mechanical means
(electric fan) the following conditions will have to be observed:

a) if in the premise is present an outlet duct not in use, it must

be closed

b) The ventilation opening of the premise in which have been

installed gas appliances must be increased in compliance
with the maximum air discharge needed by the electric fan,
according to the following table:

c) the electric fan must not influence the correct exhaust of the

combustion products in case of appliances that collect the
combustion air in the room. This should be checked through
a draught test by making the fan work at maximum speed
and the gas appliance at maximum and minimum rated power
stated by the manufacturer. Furthermore, in case the applian-
ce is connected to a ramified network flue, the electric fan
running at maximum speed together with the appliance
switched off, must not cause a vacuum in the premise as to
the stack itself.

Note 1 - If the solenoid valve is installed in a premise without

openings, the necessary air inflow must take place
through a ventilation duct, or directly from an adja-
cent premise, provided with adequate opening. If in
this last premise is installed a gas appliance, the nec-
essary ventilation air will be the one for the appliance
increased by the one necessary for the presence of
the electric fan.

Note 2 - The actual discharge of an electric fan is in accord-

ance to the volume of the room to be ventilated, bear
in mind that for a kitchen the hourly air change is 3 - 5
times its volume.

7. Evacuation de l’air vicié

Dans les locaux où sont installés des appareils à gaz, en plus
de l’introduction d’air comburant, on peut avoir besoin d’éliminer
également l’air vicié, en introduisant par conséquent le même
volume d’air propre et non vicié (fig. 6).
Si l’évacuation de l’air vicié est effectué à l’aide d’un moyen
mécanique (électroventilateur), il faudra respecter les conditions
suivantes:

a) si le local possède un conduit d’évacuation ordinaire hors

service, il faut le boucher

b)  l’orifice de ventilation du local où sont installés les appareils

à gaz doit être augmenté en fonction du débit d’air maxi-
mum nécessaire à l’électroventilateur, d’après le tableau
suivant:

c) l’action de l’électroventilateur ne doit pas influencer l’éva-

cuation correcte des produits de la combustion dans le cas
d’appareils prélevant l’air de combustion dans la pièce. Il fau-
dra donc vérifier ce point en effectuant un essai de tirage, en
faisant fonctionner le ventilateur à sa puissance maximum
et l’appareil à gaz aux puissances nominales maximum et
minimum déclarées par le constructeur. De plus, dans le cas
d’appareil relié à un conduit collectif ramifié (c.c.r.),
l’électroventilateur à sa puissance maximum et avec l’appa-
reil atteint ne doit pas mettre le local en dépression par rap-
port au c.c.r. proprement dit.

Note 1 - Si l’électroventilateur est installé dans un local sans

ouvertures, l’afflux de l’air qui lui est nécessaire doit
s’effectuer à travers un conduit de ventilation ou bien
directement d’une pièce adjacente, munie d’ouver-
ture adéquate. Si un appareil à gaz est installé dans
ce dernier local, l’air de ventilation nécessaire sera
celui pour l’appareil augmenté de l’air requis par la
présence de l’électroventilateur.

Note 2 - Le  débit  effectif d’un électroventilateur dépend du

volume de la pièce à ventiler, en tenant compte que
pour un local de cuisine, le renouvellement horaire
d’air est de 3 à 5 fois son volume.

Maximum

Air inlet

Air passage

discharge

speed

additional net

in m

3

/h

in m/s

cross section

in cm

2

up to 50

1

140

over 50 

-

 100

1

280

over 100 

-

 150

1

420

Débit

Vitesse

Section

maximum

 entrée air nette supplémentaire

en m

3

/h

en  m/s

en passage air

en cm

2

Jusqu’à 50

1

140

au-delà de 50 

÷

100

1

280

au-delà de 100 

÷

150

1

420

Содержание A 478/4G

Страница 1: ...SERIE A 2010 COUNTERTOP GAS HOBS DEPTH CM 45 50 TABLES DE CUISSON GAZ POSER PROF 45 50 CM INSTRUCTIONS MANUAL LIVRET D INSTRUCTIONS GB Class 1 FR Class 1...

Страница 2: ...2...

Страница 3: ...ctrique A 529 2GR A 529 2GG A 538 2GR A 538 2GG 22 A 548 3G 23 A 478 4G A 558 4G 24 A 488 5G A 498 5G A 568 5G 25 A 578 6G A 588 6G 26 Etiquette technique 28 INDEX Important directions page 4 Technica...

Страница 4: ...manuel et con servez le dans un endroit accessible pour toute consultation ul t rieure Au moment de l ouverture de l emballage assurez vous que l ap pareil soit intact Ne laissez pas la port e des enf...

Страница 5: ...er inox au nickel chrome 19 10 Les c bles qui du g n rateur d tincelles portent le courant aux bougies d allumage sont en cuivre tam 7 rh ophores rev tus de teflon et gaine de verre TECHNICAL AND STRU...

Страница 6: ...sation en fai sant attention qu ils ne touchent pas les surfaces et qu ils ne restent pas proximit de l appareil en fonction ou bien pas compl tement refroidi Pour allumer les br leurs presser et tour...

Страница 7: ...soft damp sponge To clean the pan supports and flame dividers use a slightly abrasi ve 3M Scotch Brite pad Avoid acid based detergents chloric hydrofluoric phosphoric and muriatic abrasive scrubbers...

Страница 8: ...plan peut s liminer facilement en relevant l appareil et en l inclinant de 30 maxi mum apr s avoir essuy les ventuels liquides pr sents sur la table de cuisson Durant le nettoyage v rifier que les tr...

Страница 9: ...s pres criptions des normes in vigueur Une attention particuli re sera accord e aux dispositions appli cables en mati re de ventilation conform ment aux arr t s du 2 Ao t 1977 et la Norme D T U P45 20...

Страница 10: ...tiler fig 1 et 2 Ces ouvertures doivent satisfaire les conditions suivantes a avoir une section libre totale nette de passage d au moins 6 cm2 pour chaque kW de d bit thermique install avec un minimum...

Страница 11: ...11 Fig 3 Fig 2 Fig 1 Fig 4...

Страница 12: ...r and the floor 6 Ventilation naturelle indirecte L afflux de l air peut provenir galement d un local adjacent fig 5 condition que le local adjacent soit muni de ventilation directe conforme aux parag...

Страница 13: ...n d air comburant on peut avoir besoin d liminer galement l air vici en introduisant par cons quent le m me volume d air propre et non vici fig 6 Si l vacuation de l air vici est effectu l aide d un m...

Страница 14: ...classe 1 Il faut que toutes les op rations relatives l installation au r glage l adaptation au type de gaz disponible soient effectu es par du personnel qualifi conform ment aux normes nationa les en...

Страница 15: ...K PANEL OR WALL 2 5 min DU DOSSERET OU DU MUR 50 5 1 5 1 13 6 23 6 5 1 5 2 5 CUTOUT TROU D ENCASTREMENT R 1 CUTOUT TROU D ENCASTREMENT COUNTERTOP THICKNESS max 4 5 min 2 5 PAISSEUR PLAN max 4 5 min 2...

Страница 16: ...OU D ENCASTREMENT CUTOUT TROU D ENCASTREMENT Measurements expressed in cm Measurements expressed in cm Dimensions exprimees en cm Dimensions exprimees en cm COUNTERTOP THICKNESS max 4 5 min 2 5 PAISSE...

Страница 17: ...ircuit du gaz est parfaite en utilisant une solution savonneuse mais jamais une flamme V rifier galement que le tuyau de raccordement ne peut pas se trouver en contact avec des parties mobiles qui pou...

Страница 18: ...by side make individual gas connections as indicated in fig 10 Plans de cuisson juxtapos s Dans le cas de juxtaposition de deux tables de cuisson ou plus le raccordement au gaz devra tre fait s par me...

Страница 19: ...ELECTRIQUE Ces tables de cuissons sont munies d un c ble d alimentation tripolaire type HAR H05 RR F section 3x1 mm2 L 1 35 m pr vues pour le fonctionnement avec courant alternatif la ten sion de 230...

Страница 20: ...des or escapes fit it properly inside the knob socket TRANSFORMATION AU GAZ LIQUIDE GPL ET REGLAGE DU MINIMUM La table de cuisson est pr vue pour utiliser du gaz m thane la pression de 20 mbars comme...

Страница 21: ...1 23 adjusted r gl adjusted r gl BURNER BRULEUR Thermic flow rate kW D bit thermique kW Butan gas Gaz butane G30 28 mbar Flow rate g h D bit g h Injector Buse By pass Propane gas Gaz propane G31 37 mb...

Страница 22: ...tor for ignition of burners MG Earthing on generator support fastening screw R Resistance 5W 27K RM Valve with microswitch for knob activated ignition Legende CA C ble d alimentation section 3x1 MO Po...

Страница 23: ...tion of burners MG Earthing on generator support fastening screw R Resistance 5W 27K RM Valve with microswitch for knob activated ignition Legende CA C ble d alimentation section 3x1 MO Porte bornes a...

Страница 24: ...gnition of burners MG Earthing on generator support fastening screw R Resistance 5W 27K RM Valve with microswitch for knob activated ignition Legende CA C ble d alimentation section 3x1 MO Porte borne...

Страница 25: ...ator support fastening screw R Resistance 5W 27K RM Valve with microswitch for knob activated ignition Legende CA C ble d alimentation section 3x1 MO Porte bornes art PA 299 CB Bougies br leurs GS G n...

Страница 26: ...ignition of burners MG Earthing on generator support fastening screw R Resistance 5W 27K RM Valve with microswitch for knob activated ignition Legende CA C ble d alimentation section 3x1 MO Porte born...

Страница 27: ...27...

Страница 28: ...d with the utmost operational freedom Le Constructeur d cline toute responsabilit pour les inexactitudes contenues dans opuscule et imputables des erreurs d imprimerie ou de transcription pour les dom...

Отзывы: