background image

14

TECHNICAL SPECIFICATIONS

Brand

: ALPATEC

Reference

: AC 10 FT

Rotative compressor

: with R 410 A / 600 g

Cooling class

: A

Annual consumption (kW)

: 485

Cooling capacity (kW)

: 2,53

EER

: 2,61

Type 

: cooling only

Cooling mode

: by air

Heating capacity (kW)

: NA

Heating class

: NA

Noise level dB(A)

: 52

Power supply

: 220-240 V, 50 Hz

Dehumidification

: 60 litres / jour

Air flow

: 310 m

3

/ h

Fan speed

: 3

Exhaust pipe length

: 150 cm

Exhaust pipe diameter

: 130 mm

Suitable for rooms up to 

: 22 m

2

Dimensions

: 86,8 x 44,3 x 35 cm

Weight

: 39 kg

ELECTRIC DIAGRAM

11

PANNE.

En cas de mauvais fonctionnement et avant de faire appel à un réparateur agréé, vérifier les points suivants :

Problème

Causes possibles

Solutions possibles

L’appareil ne fonctionne

- Il n’est pas branché

- Le brancher

pas

- La prise électrique est endommagée - La faire changer

- Le fusible ou le cordon 

- Rapporter votre appareil chez un

d’alimentation de l’appareil sont 

réparateur agréé qui procèdera à la

endommagés

réparation

L’appareil s’arrête 

- La programmation était activée

- Annuler la programmation 

automatiquement

Pas d’air froid en mode 

- La température de la pièce est 

- Fonctionnement normal

climatisation

inférieure à la température de 

consigne

- L’évaporateur est gelé

- Eliminer la glace sur l’évaporateur

L’écran VFD affiche 

- Le circuit de réfrigérant est 

- Le faire changer par un réparateur 

E3.E4.E5

endommagé

agréé.

L’écran VFD affiche E2

- Le bac à eau est plein

- Vider le bac à eau

L’écran VFD affiche E1

- Le voltage est trop élevé ou 

- Eteindre l’appareil et le remettre en

trop bas

marche lorsque le voltage est 

normal

- Le produit est endommagé

- Amener votre produit chez un 

réparateur agréé

Si votre produit a un fonctionnement anormal, arrêtez le et amenez le chez votre revendeur ou bien un

réparateur agréé.

Содержание AC 10 FT

Страница 1: ...du recyclage de la r utilisation mat rielle ou par les autres formes de r utilisation des appareils usag s Veuillez vous adresser votre municipalit pour conna tre la d chetterie comp tente Instructio...

Страница 2: ...l ext rieur dans un environnement humide pr s d une baignoire d une douche ou d une piscine Ne pas immerger cet appareil ou le cordon d alimentation Cet appareil est livr avec un c ble d alimentation...

Страница 3: ...mal Unit is damaged Make it repair by a qualified person When there is something wrong with your unit contact a qualified person 3 CARACT RISTIQUES Marque ALPATEC R f rence du mod le AC 10 FT Compress...

Страница 4: ...it Do not use chemical solvent Use a dry and wet cloth to clean the outside of the unit Anti dust air filter If the anti dust air filter is dirty the air conditioner will be less performing Clean the...

Страница 5: ...the unit is running Set remaining time before stopping using J Each pressure adds or removes half an hour from 0 5 to 12h Remaining time before stopping is displayed on VFD screen and adjusted every h...

Страница 6: ...PEED Use touche VITESSE M Each pressure fan speed changes according to following diagram LOW MEDIUM HIGH DRY ONLY MODE During the dry operation the fan speed cannot be adjusted Low speed will be set a...

Страница 7: ...g 8 Fig 6 Fig 8 Fig 7 Fig 6 bis 7 MISE EN PLACE DE LA GAINE D VACUATION DE L AIR CHAUD Monter l extr mit 15 sur la gaine Positionner la gaine sur le climatiseur dans le logement arri re 10 A travers u...

Страница 8: ...pondance sur t l commande J 2 K 3 L 5 M 6 N 4 Sur l cran de la t l commande les pictogrammes des diff rents param tres s afficheront MISE EN MARCHE Brancher l appareil celui ci met un son bip Ouvrir l...

Страница 9: ...a touche M A J pour arr ter l appareil Celui ci met un son bip et s arr te de fonctionner PROGRAMMATION Pour programmer un d part diff r de l appareil presser une fois la touche TEMPS M lorsque l appa...

Страница 10: ...e bac est plein l erreur E2 s affiche sur l cran VFD l appareil s arr te de fonctionner Pour vider le bac arr ter le climatiseur positionner le bac eau amovible 16 sous le bouchon de vidange 7 retirer...

Страница 11: ...ctrique est endommag e La faire changer Le fusible ou le cordon Rapporter votre appareil chez un d alimentation de l appareil sont r parateur agr qui proc dera la endommag s r paration L appareil s ar...

Страница 12: ...plied and recommended by the manufacturer This could be dangerous and may damage the appliance Do not use if power cord or appliance is damaged Only use this appliance for domestic purpose following t...

Отзывы: