Alnor e-MOCarz Скачать руководство пользователя страница 19

Expansion Electronic     

Prolife REOCLEAN50 

3

I N S T A L L A T I O N   O F   T H E

M A C H I N E

3 . 1

M E C H A N I C A L   I N S T A L L A T I O N

Screws    

  Bracket

Electrical terminal board 

Fit the brackets supplied on the module with the screws 

Installing the equipment to the wall or ceiling using appropriate expansion bolts not supplied. 

Ceiling installation

Wall installation

Installing the equipment to the wall or ceiling using appropriate expansion bolts not supplied.

Round connector (sold separately)

Fix the adapter for the round duct 

to the the device

Connect the pipes input-output observing the direction of the air flow indicated on the module.

3.2 Adapters

The air filter can be additionally equipped with adapters 

e-MOCarz-PR-160 /200 /250 

(option) to connect 

the device to the round ductwork. Round connectors are made of galvanised steel and factory-fitted with an 

EPDM seal. Available duct diameters: Ø160, Ø200 and Ø250.

19

ALNOR

®

 

ventilation systems

is a legally protected trademark and technical patent. All rights reserved.

w

w

w

.al

nor

.com.
pl

User’s manual

e-MOCarz

Содержание e-MOCarz

Страница 1: ...Elektrostatyczy filtry antysmogowy e MOCarz INSTRUKCJA OBS UGI USER S MANUAL Kwiecie April 2021 Anti smog electrostatic precipitator e MOCarz...

Страница 2: ...i cz ci 8 4 4 Metalowy filtr wst pny 8 4 2 Filtr elektrostatyczny 9 4 2 1 Pr ty jonizacyjne 10 4 2 2 P ytki zbieraj ce 10 4 2 3 Izolatory 10 4 2 4 Tabliczka elektryczna i przy cze elektryczne 10 5 Zab...

Страница 3: ...filtr elektrostatyczny kt ry wykorzystuje pr d elektryczny i zjawiska wy adowa elektromagnetycznych Aby uzyska najlepsz wydajno filtra zar wno pod wzgl dem skuteczno ci filtracji jak i niskiego spadku...

Страница 4: ...iecznie zapakowa urz dzenie z zabezpieczeniem w postaci styropianu odes a urz dzenie do producenta lub lokalnego sprzedawcy 3 Monta filtra 3 1 Instalacja Filtr jest przeznaczony do monta u w kana ach...

Страница 5: ...a do kana u okr g ego do urz dzenia Po czy przewody wej ciowe wyj ciowe zgodnie z kierunkiem przep ywu powietrza wskazanym na urz dzeniu 3 2 Przy cza Filtr powietrza mo e by dodatkowo wyposa ony w prz...

Страница 6: ...Rysunek nr Temat Nazwa projektu REOCLEAN 50 1 3 30 07 2020 Klient ALNOR Systemy Wentylacji sp z o o Tytu strony REOCLEAN 50 PCSCHEMATIC Automation Nazwa pliku Reoclean50 Ozn ref strony Opis 30 07 2020...

Страница 7: ...odu zerowego i uziemienia W przypadku dodania modu u jonizuj cego e MOCarz ION nale y post powa zgodnie ze schematem poni ej Strona Poprzednia strona Nast pna strona Liczba stron rozdzia u Ost wydruk...

Страница 8: ...ly Depending on the model it is fitted in it can have different dimensions which are illustrated below DIMENSIONS FILTER MODEL A B C e MOCarz 324 282 10 During operation the metal pre filter must alwa...

Страница 9: ...anticorodal aluminium There are four distinct zones in the cell A ionisation wires B collection blades C insulators D electronic board electric connector D C A B Wymiary A mm B mm C mm 325 283 105 Exp...

Страница 10: ...ne jest punktem po czenia elektrycznego przewodu zasilaj cego z uk adem zasilania tabliczki elektrycznej w celu wytworzenia wysokiego napi cia dla filtra elektrostatycznego Podczas konserwacji nale y...

Страница 11: ...t przez wyspecjalizowany personel 6 1 Konserwacja filtra Aby przeprowadzi konserwacj filtra nale y uzyska do niego dost p poprzez drzwiczki Konserwacja filtra polega na umyciu filtra i metalowego filt...

Страница 12: ...ing materials are required for maintenance 1 Two plastic trays one with the bottom raised 2 3 cm for decanting the dirt As an alternative to the raised bottom use a stainless steel frame 2 Non corrosi...

Страница 13: ...p uka go wod c pozostawi do wyschni cia w ciep ym i dobrze wentylowanym miejscu 6 2 Og lny przegl d filtr w Stan techniczny filtr w nale y sprawdza przy ka dym myciu aby zapobiec wadliwemu dzia aniu i...

Страница 14: ...ia dotycz ce filtracji i zasilania modu u jonizacji ujemnej je li dost pna wraz z wymaganymi informacjami o stanie roboczym urz dzenia Jonizacja ujemna System podstawowy BASIC pozwala na ci g ujemn jo...

Страница 15: ...oprawnie op ukany na izolatorach mo e znajdowa si deter gent ponownie dok adnie op ucz filtr mi dzy p ytkami zbieraj cymi zebra o si niewielkie zabrudzenie na izolatorach mo e znajdowa si deter gent p...

Страница 16: ...lectric connector 24 5 Safety devices 24 5 1 Mechanical safety devices 24 5 2 Electrical safety devices 24 5 2 1 Electrostatic circuit protection devices 25 5 3 Fuse 25 6 Ordinary maintenance 25 6 1 F...

Страница 17: ...ISO 16890 This is an electrostatic precipitator which uses electrical current and electromagnetic phenomena We recommend the airflow at 575 m3 h at most to reach best performance regarding both filte...

Страница 18: ...protection ship to the manufacturer or to the local dealer 3 Installation of the filtering device 3 1 Installation This filter is designed for duct installation either in rectangular or round ventila...

Страница 19: ...he round duct to the the device Connect the pipes input output observing the direction of the air flow indicated on the module 3 2 Adapters The air filter can be additionally equipped with adapters e...

Страница 20: ...emat Nazwa projektu REOCLEAN 50 1 Klient ALNOR Systemy Wentylacji sp z o o Tytu strony REOCLEAN 50 PCSCHEMATIC Automation Nazwa pliku Reoclean50 30 07 2020 StrTyt 2 1 2 3 4 5 6 7 8 e MOCarz ALNOR vent...

Страница 21: ...g additional ionisation kit e MOCarz ION act according to the following diagram Strona Poprzednia strona Nast pna strona Liczba stron rozdzia u Ost wydruk Ost zmiana Rewizja str Rewizja proj Zatw inic...

Страница 22: ...ding on the model it is fitted in it can have different dimensions which are illustrated below DIMENSIONS FILTER MODEL A B C e MOCarz 324 282 10 During operation the metal pre filter must always be in...

Страница 23: ...al aluminium There are four distinct zones in the cell A ionisation wires B collection blades C insulators D electronic board electric connector D C A B Dimensions A mm B mm C mm 325 283 105 Expansion...

Страница 24: ...onic bord to generate the high voltage for the electrostatic cell During maintenance inspect to ensure that the contact are clean and intact Also ensure that there are no burns or cracks on the plasti...

Страница 25: ...y the technical service 6 Ordinary maintenance Ordinary maintenance involves maintenance of the filter unit general inspection of the device Extraordinary maintenance is carried out by specialised per...

Страница 26: ...r it is necessary to release the two locks with a flat screwdriver and remove the door 6 1 2 W a s h i n g t h e f i l t e r s Filter maintenance is important both for the correct operation of the mac...

Страница 27: ...hly with water c leave to dry in a warm ventilated environment 6 2 General inspection of the filters The state of the filters must be inspected every time they are washed so as to prevent air cleaner...

Страница 28: ...isation module if provided along with the information required on the operating status of the apparatus Negative ionisation The BASIC SYSTEM allows a continually negative environmental ionisation 7 1...

Страница 29: ...d there may be detergent on the insulators the cell must be thoroughly rinsed again small bodies trapped between the collection blades there may be detergent on the insulators the cell must be thoroug...