Touchpad

•  The touchpad should be mounted indoors in a dry area.

•  The touchpad connects to the power unit with the provided 20’ data cable. If you need a longer data cable for your application, 

you may purchase one directly from Almost Heaven Saunas. 

CONNECTING YOUR HEATER TO POWER

Please note, the power unit provided with your sauna is rated for single-group connection. The instructions below are for single-

group connections only.  

Incoming Power

First, you will need to bring power to your power unit. Remove the power unit’s cover and pry out the appropriate knockouts that 

will allow the wiring to enter and exit the unit. 

Note: for visual purposes the wiring images you will see in this manual do not utilize the knockouts.

Connect the power cord to the appropriate terminals, with the two hot lines connecting to the left-most L1 and L2 terminals, and 

the ground connecting to the ground terminal. A neutral line is not needed - this is only required if a light or ventilation fan is 

connected to the power unit, an application that is not available in the U.S. market. 

Power Unit Wiring

Содержание Virta HL6U1

Страница 1: ...llation Owner s Manual This guide should be used in conjunction with the manufacturer s heater manual found inside the heater box Please be sure you and your electrician review both before installatio...

Страница 2: ...y installed you should expect your Harvia Virta heater to consistently heat to 180 190 degrees fahrenheit YOUR HEATER S WARRANTY In a residential setting your Harvia heater comes with a 1 year warrant...

Страница 3: ...r for your heater will connect here first and then relay onto your heater Next consider where you d like to mount your touchpad You can mount the touchpad wherever it s most convenient for you We do n...

Страница 4: ...ons only Incoming Power First you will need to bring power to your power unit Remove the power unit s cover and pry out the appropriate knockouts that will allow the wiring to enter and exit the unit...

Страница 5: ...bber gaskets under the heater this is where the wire will enter the heater Using the same gauge wire you used to bring power to the power unit connect the left most outgoing L1 and L2 power unit termi...

Страница 6: ...hould connect in the following order blue white red yellow Touchpad The touchpad should be mounted indoors in a dry location preferably in your home Once you ve determined this location use a flathead...

Страница 7: ...is connected correctly the buttons at the bottom of the screen should illuminate The bottom left button is the main power unit press it and you should hear a loud clunk from the power unit which is t...

Страница 8: ...y pressing the reset button under the heater as the high limit safety circuit may have been tripped If this continues to happen your sensor may be too high or too close to the heater This is a traditi...