background image

RC3-LOG & RC3P-LOG INSTRUCTION MANUAL 

 

 

Page 

15

 

 

SHAWALMEX-EUROPE BV

 

 

 RC3-LOG & RC3P-LOG INSTRUCTION MANUAL SEPT 2018 

 
 

 

 

2.

 

Faulty temperature controller. 

2.

 

Refer to ALMEX NANODAC instruction manual. 

 

 

3.

 

Faulty RTD temperature 
sensor. 

3.

 

Measure the resistance between pins 4-5 and 4-6 on the 
platen electrical receptacle. Depending on the platen 
temperature, the resistance should be between 100-170 
Ohms. 

7.5. 

Controller will not maintain Set Point Temperature 

FAULT 

CORRECTION 

1.

 

Controller not calibrated 
properly. 

1.

 

Follow calibration procedure. 

2.

 

Faulty temperature controller. 

2.

 

Refer to ALMEX NANODAC instruction manual. 
Replace temperature controller 

 

8. 

Service 

8.1. 

Emergency Service 

Contact:

 

Service Department 

Telephone:

 

+31 652 667 301 

Fax:  

 

+31 842 202 967

 

Mail:

 

 

SHAW ALMEX EUROPE BV

 

 

 

PO BOX 16 

 

 

9247 ZN, Ureterp 

 

 

The Netherlands 

E-mail:

   

[email protected] 

8.2. 

Return of Goods Authorization 

The service department of Shaw-Almex Industries Limited MUST be contacted for the necessary authorization 
and documentation prior to returning goods to the factory. 

The service department may be reached at the above numbers. 

8.3. 

Guarantee 

Your ALMEX vulcanizer is guaranteed against defective parts, material and workmanship for a period of 12 
months from the date of purchase.  For complete details, refer to the Warranty Card. 

 

Содержание RC3-LOG

Страница 1: ...ATALOGGING TEMPERATURE CONTROL PANEL This manual was prepared to present the correct methods and procedures of operating and maintaining your ALMEX TEMPERATURE CONTROL PANEL Read this manual carefully...

Страница 2: ...Platen Temperature 7 5 1 2 Protecting Temperature Controller Settings 5 2 1 Set the Timer 10 5 3 Heating the Vulcanizer 11 5 3 1 Manual Heating 12 5 4 Temperature Control 12 6 MAINTENANCE 12 6 1 Open...

Страница 3: ...RC3P LOG Serial Number Weight 15 kg Voltage 380 420 volt Phase 3 Cycle Hertz 50 60 Amperage Maximum Per Platen 16 Amp Total 32 Amp Circuit Overcurrent Protection Required 32 Amp Temperature Sensor 100...

Страница 4: ...LOG Year of Construction 2018 has been manufactured using the following transposed harmonized European Standards EN 60204 1 Safety EN 50081 1 Emissions EN55011 EN 50082 1 Immunity EN61000 4 2 3 4 5 a...

Страница 5: ...mperature control panel 2 All of the electrical components contain live circuits Do not open or service any of the electrical equipment without disconnecting the main power supply 3 Incorrect voltage...

Страница 6: ...T 2018 4 ASSEMBLY 4 1 Unpacking Carefully unpack temperature control panel from the box and inspect for damage Any damages or shortages should be reported to the carrier and or SHAW ALMEX EUROPE BV 4...

Страница 7: ...ure set points for top and bottom platen The temperature controller has many other settings that have been set by the factory The operator interface consists of a display screen and four navigation pu...

Страница 8: ...in many cases allowing the user to select one from a number of alternative values within menu items Theses keys are also used to navigate through the virtual keyboards and number pads used to enter te...

Страница 9: ...Platen Temperatures Push the page button untill the Process overview screen Figure 5 is shown Push the scroll button and the raise lower buttons to select the setpoint or dwelltime that needs to be c...

Страница 10: ...can be set to the desired value Once the desired value has been reached push the scroll button once more to enter the new value Pushing the page button will lock the new temperature value Important Th...

Страница 11: ...sq cm before heating 3 Press the blue TIMER RESET button at the timer Setting the A M button to A will start the heat cycle 4 Turn the A M switch to the A on automatic position to begin heating the vu...

Страница 12: ...otherwise excessive temperatures will occur 3 The parameters can be adjusted so that set point is reached in the fastest possible time straight line heating but this will cause the temperature to ove...

Страница 13: ...calibration unless the controller the heating element or the temperature sensor is changed Refer to the special autotuning instructions for autotuning your RC3 P log controller 7 TROUBLESHOOTING This...

Страница 14: ...iving incoming power and is receiving a signal from the controller but is not sending outgoing power then that relay is faulty and must be replaced 7 Loose connection in cable or platen connector 7 Re...

Страница 15: ...ture controller 2 Refer to ALMEX NANODAC instruction manual Replace temperature controller 8 Service 8 1 Emergency Service Contact Service Department Telephone 31 652 667 301 Fax 31 842 202 967 Mail S...

Отзывы: