Page
15
SHAWALMEX-EUROPE BV
RC3-LOG & RC3P-LOG INSTRUCTION MANUAL SEPT 2018
2.
Faulty temperature controller.
2.
Refer to ALMEX NANODAC instruction manual.
3.
Faulty RTD temperature
sensor.
3.
Measure the resistance between pins 4-5 and 4-6 on the
platen electrical receptacle. Depending on the platen
temperature, the resistance should be between 100-170
Ohms.
7.5.
Controller will not maintain Set Point Temperature
FAULT
CORRECTION
1.
Controller not calibrated
properly.
1.
Follow calibration procedure.
2.
Faulty temperature controller.
2.
Refer to ALMEX NANODAC instruction manual.
Replace temperature controller