background image

Series SLTP, SETP, SNTP, SLTBP, SETBP, SNTBP

ALLWEILER

a

16

Sectional drawing 

for series SLTP, SETP and SNTP

Part No.

Denomination

Qty.

101 (1)

Key

1

102 (1)

Spacer sleeve

1

103 (1)

Radial bearing

R

1

104 (1)

Axial bearing

R

1

105 (1)

Sealing washer

R

1

107 (1)

Bearing grease

0

108 (1)

Circlip

1

109 (1)

O-ring

R

1

110 (1)

Bearing bracket

1

111 (1)

Bearing cover

1

112 (1)

Lip seal, pump side

R

1

113 (1)

Spacer ring

1

114 (1)

Flinger ring

1

115 (1) (2)

O-ring

R

1

Part No.

Denomination

Qty.

116 (1)

Bearing nut

1

117 (1)

Locking device 
for bearing nut

1

118 (1)

Drive shaft

R

1

119 (1)

Lubricating nipple

2

120 (1)

Lip seal, drive side

R

1

122 (3)

Lantern

1

123 (3)

Pin

1

125 (3)

Hollow shaft

R

1

138 (1)

Grease quantity regulator

1

141 (3)

Lubricating paste

201 (4)

T-head bolt

2

202 (4)

Self-locking nut

2

Part-No.

Denomination

Qty.

203 (4)

Gland

1

204 (4)

Shaft sealing housing

1

205 (2)

Shaft sleeve

1

206 (2)

Shaft wear sleeve

R

1

207 (4)

Stuffing box packing

R, r

1

208 (5)

Flushing ring

1

209 (6)

Lantern ring

1

212 (7)

Screw plug

1

213 (7)

Sealing ring

1

214 (8)

Mechanical seal housing

1

215 (9)

Mechanical seal cover

1

216 (10)

Clamping ring

1

217 (11)

Centering ring

1

218 (8)

O-ring

R

1

Bearing: 

(regreasable)

Shaft seal:

G10

to 

G13 

mechanical seal, 

single-acting, non-balanced, 
direction-independent, with shaft  
wear sleeve. 
With vent line to the discharge 
connection.

G00

to 

G03 

as G10 to G13, however,  

without shaft wear sleeve.

Содержание SETBP Series

Страница 1: ...ning these operating instructions must by all means be read by the fitter as well as the pertinent expert person nel customer and must always be available at the place of installation of the machine p...

Страница 2: ...according to Section 1 General of the operating instructions The limit values given in the data sheet must by no means be exceeded 3 Transportation and intermediate storage 3 1 Packing The symbols app...

Страница 3: ...Nominal diameters The nominal diameter of the suction line should be designed according to the nominal pump branch dia meter In case of considerable deviations please contact the factory 5 5 2 Suppor...

Страница 4: ...nd properties of the flushing sealing liquid B Any liquid may be used as sealing flushing liquid in consideration of the corrosion resistance of all contacted parts and the consistency with the medium...

Страница 5: ...fer to the Dismounting and Mounting Instructions 5 6 2 4 Dry run protection After start up it must be ensured that the flow of liquid on the suction side is never completely interrupted in order to pr...

Страница 6: ...ioning of the stuffing box after re packing Prior to commissioning the stuffing box must be only slightly tightened During pump starting 50 to 200 drops in a minute are admissible as seepage quan tity...

Страница 7: ...5 pieces 168 1 x 08 037 0400 100 2 58 42 x 8 400 1 200 1 200 2 100 1 5 pieces 211 8 x 10 037 100 2 73 53 x 10 720 1 380 1 380 2 550 1 200 1 5 pieces 208 4 x 10 052 0650 200 2 72 52 x 10 720 1 380 1 3...

Страница 8: ...to commencing the dismounting the following operations must be performed Disconnect power supply cable from the motor Motor must not be capable of being started All shut off elements in the discharge...

Страница 9: ...ical seal single acting Withdraw mechanical seal housing 214 with atmos phere side stationary seal ring of the mechanical seal 219 from the hollow shaft 125 Note Particularly see to it that the casing...

Страница 10: ...e of models P02 P12 including flushing ring 208 and in case of models P03 P13 and P04 P14 including lantern ring 209 from the shaft sealing housing 204 In case of a model with shaft wear sleeve pull s...

Страница 11: ...pplied as described below 1 Fill hollow spaces between the rolling bodies up to approx 30 to 50 with grease 2 Scrape off excessive grease most suitably with your fingers do not use any metallic object...

Страница 12: ...eve and fill the space in the joint with Allweiler Spezialgelenk l Type B or l ET 15 10 ISO 460 of Tri bol Lubricants GmbH M nchengladbach Germany If used for foodstuffs with Allweiler Spezialgelenk l...

Страница 13: ...2 5 Mounting the stator Prior to mounting coat stator 402 rotor 401 and O ring 517 with lubricant silicon oil Polydiol soft soap or the like B Do not use ordinary oil Mount stator 402 on the rotor 401...

Страница 14: ...y only original spare parts delivered by us may be kept on stock and instal led In this connection we refer to the statements made under Section 2 7 above For spare parts replacement parts orders the...

Страница 15: ...Series SLTP SETP SNTP SLTBP SETBP SNTBP ALLWEILER a 15 For the sectional drawings and parts list please refer to pages 16 19...

Страница 16: ...seal drive side R 1 122 3 Lantern 1 123 3 Pin 1 125 3 Hollow shaft R 1 138 1 Grease quantity regulator 1 141 3 Lubricating paste 201 4 T head bolt 2 202 4 Self locking nut 2 Part No Denomination Qty...

Страница 17: ...t R r 0 306 Clamping band R r 4 307 Coupling rod R r 1 308 Cover sleeve R r 2 Part No Denomination Qty 401 Rotor R r 1 402 Stator R r 1 502 12 Screw plug 1 503 12 Sealing ring 1 504 Discharge casing 1...

Страница 18: ...3 however without shaft wear sleeve G18 and G19 Mechanical seal double acting non balanced direction independent with shaft wear sleeve G08 and G09 as G18 and G19 however without shaft wear sleeve 1 N...

Страница 19: ...thread to DIN 13 Pipe thread to DIN 2999 Stuffing boxes P14 and P04 Mechanical seals G18 and G19 and G08 and G09 n standard direction of flow N possible direction of flow Stuffing boxes P13 and P03 M...

Страница 20: ...n bodies in pump disas semble pump remove foreign bodies replace defective parts Stator and rotor worn disassemble pump replace defective parts Joint parts f g and or drive shaft and or shaft wear sle...

Отзывы: