background image

– Press  stationary  seal  rings  of  the  mechanical  seals

and O-rings out of the mechanical seal housing (214)
and  mechanical  seal  cover  (215).  See  to  uniform
pressure distribution.

– Remove locking pin (220).

– In case of a model with shaft wear sleeve, withdraw

shaft  wear  sleeve  (206)  and  O-ring  (115)  from  the
drive shaft (118).

7.2.2

Mounting the eccentric screw pump

General

Mounting of the individual pump components is effect-
ed after careful cleaning analogously in reverse order.

7.2.2.1 Mounting  the  shaft  seal  with  the  drive  shaft  and/or

hollow shaft dismounted

– For  design  with  shaft  wear  sleeve,  pull  O-ring  (115)

onto drive shaft (118).

– Push  shaft  wear  sleeve  (206)  with  the  inside  bevel

pointing to the drive shaft head onto the drive shaft
(118).

x

Mounting the stuffing box

– Push shaft sealing housing (204) onto the shaft wear

sleeve (206) and/or onto the drive shaft (118) or hol-
low shaft (125).

– In  case  of  models  P02,  P12  including  flushing  ring

(208)  and  in  case  of  models  P03,  P13  and  P04,  P14
including  lantern  ring  (209),  install  stuffing  box
packing  (207)  in  the  shaft  sealing  housing  (204).
Please  also  refer  to  Section  7.1.2.3  –  Mounting  new
packing rings.

x

Mounting the mechanical seal, general

Mechanical  seals  are  high-quality  precision  parts.  The
mounting instructions of the mechanical seal manufac-
turers are to be observed. Careful handling and extreme
cleanliness  during  mounting  are  a  condition  of  proper
functioning.  To  facilitate  mounting,  surfaces  on  which 
O-rings  are  sliding,  may  be  lubricated  with  lubricants
such as silicon oil, Polydiol or soft soap.

B

Do not use ordinary oil.

Note: 

See to it that the parts sliding on

each  other  are  only  exchanged  in  pairs.  When  using
double  PTFE-coated  O-rings,  see  to  it  that  the  joint  of
the outer coating points against the mounting direction
as otherwise, opening and/or withdrawal of the coating
may be effected (please refer to Figure 5 below).

Figure  5:  Joint  of  the  outer  coating  points  against  the
mounting direction.

x

Mounting the mechanical seal, single-acting

– Drive  locking  pin  (220)  into  the  mechanical  seal 

housing (214).

Series SLTP, SETP, SNTP, SLTBP, SETBP, SNTBP

ALLWEILER

a

10

x

Dismounting the stuffing box

– Remove self-locking nut (202), T-head bolt (201) and

gland (203).

– Pull shaft sealing housing (204) from the drive shaft

(118).

– Remove stuffing box packing (207) in case of models

P02, P12 including flushing ring (208), and in case of
models P03, P13 and P04, P14, including lantern ring
(209) from the shaft sealing housing (204).

– In case of a model with shaft wear sleeve, pull shaft

wear  sleeve  (206)  and  O-ring  (115)  from  the  drive
shaft (118).

x

Dismounting the mechanical seal, single-acting

– Withdraw mechanical seal housing (214) with atmos-

phere-side  stationary  seal  ring  of  the  mechanical
seal (219) from the drive shaft.

Note: 

Particularly  see  to  it  that  the  casing  with  sta-

tionary seal ring of the mechanical seal is withdrawn
concentrically  and  not  canted  to  avoid  damages  to
the stationary seal ring.

– Press stationary seal ring of the mechanical seal and

O-ring out of the mechanical seal housing (214). See
to uniform pressure distribution.

– Drive out locking pin (220).

– Undo grub screws, if provided, in the rotating part of

the mechanical seal (219), and withdraw mechanical
seal from the drive shaft (118).

B

Before  undoing  the  grub  screws,
mark or measure the position of the

mechanical  seal  on  the  shaft  wear  sleeve  or  drive
shaft.  Do  not  push  O-rings  over  the  pressure  marks
caused by the screws!

– In case of a model with shaft wear sleeve, withdraw

shaft  wear  sleeve  (206)  and  O-ring  (115)  from  the
drive shaft (118).

– Remove centering ring (217) with O-ring (218).

x

Dismounting the mechanical seal, single-acting
with throttled sealing water outlet

– Dismounting as for mechanical seal, single-acting.

– Remove mechanical seal cover (215) with O-ring

(218).

x

Dismounting the mechanical seal, double-acting

– Withdraw mechanical seal housing (214) with atmos-

phere-side  stationary  seal  ring  of  the  mechanical
seal (219) from the drive shaft.

Note: 

Particularly  see  to  it  that  the  casing  with  sta-

tionary seal ring of the mechanical seal is withdrawn
concentrically  and  not  canted  to  avoid  damages  to
the stationary seal ring.

– Remove O-ring (218).

– Undo grub screws in the rotating part of the mecha-

nical seal (219) and pull off mechanical seal from the
drive shaft (118).

B

Before  undoing  the  grub  screws,
mark or measure the position of the

mechanical  seal  on  the  shaft  wear  sleeve  or  drive
shaft.  Do  not  push  O-rings  over  the  pressure  marks
caused by the screws!

– Pull  off  mechanical  seal  cover  (215)  and  clamping

ring  (216)  with  product-side  stationary  seal  ring  of
the mechanical seal (219) from the drive shaft (118).

Note: 

Particularly  see  to  it  that  the  mechanical  seal

cover with stationary seal ring of the mechanical seal
is  withdrawn  concentrically  and  not  canted  to  avoid
damages to the stationary seal ring.

Содержание SETBP Series

Страница 1: ...ning these operating instructions must by all means be read by the fitter as well as the pertinent expert person nel customer and must always be available at the place of installation of the machine p...

Страница 2: ...according to Section 1 General of the operating instructions The limit values given in the data sheet must by no means be exceeded 3 Transportation and intermediate storage 3 1 Packing The symbols app...

Страница 3: ...Nominal diameters The nominal diameter of the suction line should be designed according to the nominal pump branch dia meter In case of considerable deviations please contact the factory 5 5 2 Suppor...

Страница 4: ...nd properties of the flushing sealing liquid B Any liquid may be used as sealing flushing liquid in consideration of the corrosion resistance of all contacted parts and the consistency with the medium...

Страница 5: ...fer to the Dismounting and Mounting Instructions 5 6 2 4 Dry run protection After start up it must be ensured that the flow of liquid on the suction side is never completely interrupted in order to pr...

Страница 6: ...ioning of the stuffing box after re packing Prior to commissioning the stuffing box must be only slightly tightened During pump starting 50 to 200 drops in a minute are admissible as seepage quan tity...

Страница 7: ...5 pieces 168 1 x 08 037 0400 100 2 58 42 x 8 400 1 200 1 200 2 100 1 5 pieces 211 8 x 10 037 100 2 73 53 x 10 720 1 380 1 380 2 550 1 200 1 5 pieces 208 4 x 10 052 0650 200 2 72 52 x 10 720 1 380 1 3...

Страница 8: ...to commencing the dismounting the following operations must be performed Disconnect power supply cable from the motor Motor must not be capable of being started All shut off elements in the discharge...

Страница 9: ...ical seal single acting Withdraw mechanical seal housing 214 with atmos phere side stationary seal ring of the mechanical seal 219 from the hollow shaft 125 Note Particularly see to it that the casing...

Страница 10: ...e of models P02 P12 including flushing ring 208 and in case of models P03 P13 and P04 P14 including lantern ring 209 from the shaft sealing housing 204 In case of a model with shaft wear sleeve pull s...

Страница 11: ...pplied as described below 1 Fill hollow spaces between the rolling bodies up to approx 30 to 50 with grease 2 Scrape off excessive grease most suitably with your fingers do not use any metallic object...

Страница 12: ...eve and fill the space in the joint with Allweiler Spezialgelenk l Type B or l ET 15 10 ISO 460 of Tri bol Lubricants GmbH M nchengladbach Germany If used for foodstuffs with Allweiler Spezialgelenk l...

Страница 13: ...2 5 Mounting the stator Prior to mounting coat stator 402 rotor 401 and O ring 517 with lubricant silicon oil Polydiol soft soap or the like B Do not use ordinary oil Mount stator 402 on the rotor 401...

Страница 14: ...y only original spare parts delivered by us may be kept on stock and instal led In this connection we refer to the statements made under Section 2 7 above For spare parts replacement parts orders the...

Страница 15: ...Series SLTP SETP SNTP SLTBP SETBP SNTBP ALLWEILER a 15 For the sectional drawings and parts list please refer to pages 16 19...

Страница 16: ...seal drive side R 1 122 3 Lantern 1 123 3 Pin 1 125 3 Hollow shaft R 1 138 1 Grease quantity regulator 1 141 3 Lubricating paste 201 4 T head bolt 2 202 4 Self locking nut 2 Part No Denomination Qty...

Страница 17: ...t R r 0 306 Clamping band R r 4 307 Coupling rod R r 1 308 Cover sleeve R r 2 Part No Denomination Qty 401 Rotor R r 1 402 Stator R r 1 502 12 Screw plug 1 503 12 Sealing ring 1 504 Discharge casing 1...

Страница 18: ...3 however without shaft wear sleeve G18 and G19 Mechanical seal double acting non balanced direction independent with shaft wear sleeve G08 and G09 as G18 and G19 however without shaft wear sleeve 1 N...

Страница 19: ...thread to DIN 13 Pipe thread to DIN 2999 Stuffing boxes P14 and P04 Mechanical seals G18 and G19 and G08 and G09 n standard direction of flow N possible direction of flow Stuffing boxes P13 and P03 M...

Страница 20: ...n bodies in pump disas semble pump remove foreign bodies replace defective parts Stator and rotor worn disassemble pump replace defective parts Joint parts f g and or drive shaft and or shaft wear sle...

Отзывы: