background image

TRIMMER – FUSE – RELAY   

 

P1

 WORKING TIME TRIMMER 

P2

 PAUSE TIME TRIMMER 

P3

 PEDESTRIAN TIME TRIMMER 

 

 
F1 = 

FUSE 5X20 F2A  

 

on   24Vac  

protection : blinker supply 24Vac

 

F2 =

 FUSE 5X20 T0,8A 

 

on   18Vac  

protection : electronic supply and exit 24Vdc. 

F3 =

 FUSE 5X20 T0,8A  

 

on 230Vac 

protection : blinker supplì 230Vac. 

 

RL1

 LIGHT OF COURTESY RELAY (exit 24Vdc) 

RL2

 BLINKER RELAY OF 24Vac 

RL3

 OPEN RELAY 

RL4

 CLOSE RELAY  

RL5

 BLINKER RELAY 230Vac 

DECLARATION OF CONFORMITY 

(according to ISO/IEC Guide 22 and EN 45014) 

 

Manufacturer’s Name :  

 

ALLTRONIC s.n.c. 

Manufacturer’s Address :   

Via Torino. 84—12041 Bene Vagienna (Cn) Italy 

 

 

DECLARES THAT THE FOLLOWING PRODUCT

 

 

Product Name :  

Central for Rapid/Rolling Door

 

Model : 

 

Micro6R 

 

CONFORMS TO THE FOLLOWING EMC SPECIFICATIONS BASED ON SAMPLE TESTING: 

 
 

 

 

 

EN 55011 

 

 

 

 

EN 60335-1 

 

 

 

 

EN 55014-1   

 

 

 

EN 60204-1 

 

 

 

 

EN 55014-2   

 

 

 

EN 12453 

 

 

 

 

EN 61000-3-2 

 

 

 

EN 61000-6-1 

 

 

 

 

EN 61000-3-3 

 

 

 

EN 61000-6-3 + A11 

 

The product has been tested in the typical installation configuration and with peripherals which conform to EMC Directive. 

 

I the undersigned declare that the product herewith complies with the protection requirements of the 

EMC Directive 89/336/

EEC

, the

 73/23/CEE Low Tension Directive 

and also the  

Directive

 

89/392/CEE 

(Electric Equipment Security of the Devi-

ces). 

 

Bene Vagienna, 12/07/2017  

 

 

 

 

 

 

     Allodi Francesco 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proprietario 

Control Type Micro 6R Threephase 400V or Monophase 230V 

 

For fast, rolling, sliding  and Sectional door 

Содержание Micro6R

Страница 1: ...AT THE FOLLOWING PRODUCT Product Name Central for Rapid Rolling Door Model Micro6R CONFORMS TO THE FOLLOWING EMC SPECIFICATIONS BASED ON SAMPLE TESTING EN 55011 EN 60335 1 EN 55014 1 EN 60204 1 EN 550...

Страница 2: ...K M7 21 22 Input Arial RX Radio 22 Hold 23 24 Exit from RX Radio Channel 2 6 POLE TERM BLOCK M8 25 26 Input N C Contact MUSHROOM 27 28 N O button enter of OPEN 28 29 N O button enter of CLOSE 28 30 N...

Страница 3: ...THE CYCLE il pulsante di blocco 5 e 6 di M1 lo spegne OFF THE BLINKER FIRST BLINK 4 SEC BEFORE CLOSING the button of block 5 and 6 of M1 switches it off DIP 6 ON AUTO TEST FUNCTION DW24B ACTIVATED OF...

Страница 4: ...e opening OPEN END RUN STOP THE OPENING CLOSE END RUN STOP THE CLOSING BLOCK BLOCK THE MOVEMENT With DIP8 on ON A HIGH PHOTOCELL PHOTOCELL BLOCKS IN OPENING With DIP7 on ON B LOW PHOTOCELL PHOTOCELL B...

Страница 5: ...versal time 0 5 sec Dip 4 OFF Dip 3 OFF reversal time 1 sec set of factor Dip 4 ON Dip 3 ON reversal time 2 sec Dip 4 OFF Dip 3 ON reversal time 4 sec Dip 4 ON SHUNTS SET W3 W4 W5 W6 W7 For predisposi...

Страница 6: ...working time combination P1 The control works with normally closed End run N C With the gate opened the pause timer It can be bypassed pressing the button of close after the deter minated time P2 will...

Страница 7: ...hen the motor opens The motor does not open the door com pletely Control close at once Control reverse the movement bru squely Photocell stops on Open Control does not open Control does not open Times...

Страница 8: ...l have a load of 9 Amp And they must be relating to their load periodically checked It is advisable to overhaul the relay contacts every 4 years but always according to the following condi tions Micro...