Chapter 1: AC-2500 Series Hardware
NetEnforcer AC-2500 Hardware Guide
1-23
1.
Connect the External cable from the To NetEnforcer External port (Link 1) on the
Bypass Unit to the External port on NetEnforcer (Link 1).
2.
Connect the Internal cable from the To NetEnforcer Internal port (Link 1) on the
Bypass Unit to the Internal port on NetEnforcer (Link 1).
3.
Connect the External cable from the External port on the Bypass Unit to a router
(100Base-T) connector.
4.
Connect the Internal cable from the Internal port on the Bypass Unit, to a switch
connector.
5.
Repeats Steps 1 to 4 for Link 2 to 4.
6.
Connect the D-type High Density connector from the Primary port on the Bypass
Unit to the Backup port on NetEnforcer. The 9-pin connector is plugged into the
bypass unit and the 26 pin connector is plugged into the NetEnforcer.
NOTES
To connect a secondary NetEnforcer for Parallel Redundancy, you need
two NetEnforcers and one Bypass Unit.
Internal and external connectors of the redundant NetEnforcer should be
connected directly to the network. There is no need to connect via the
Bypass Unit.
Powering Up
Connection to AC Power
Power supply cords are intended to serve as the disconnect device. The user can power
down the device only by removing the two-power cords from the power source or the
device itself.
Make sure the wall socket outlet is installed near the equipment and that the socket is
easy to access. It is recommended that the wall socket outlet be connected to the
building installation protection.