14
230V
1
15V
GRD
LINE 1 LINE 2
All gate operators
be properly grounded.
A proper ground in a gate operator installation minimizes or prevents damage from an electrical charge, such as a near
lightning strike or an electrical static discharge.
.
Use a single wire for the ground.
splice two wires for the ground. If the wire breaks or is cut, replace it with a
single length.
use two wires for the ground.
Check with your City code for proper earth ground rod type and proper grounding procedures.
DO NOT
NEVER
MUST
ELECTRICAL CONNECTION
120 Volt
Electrical
Plug.
Power connection | 115VAC | 220VAC Single Phase
LINE 1
LINE 2
ground rod
= 115V N 220V LINE 1
= 115V HOT
220V LINE 2
Connect to
. Use a proper
for a
ground reference.
Use the shortest and thickest wire possible for ground.
ground
GND
For power wire enclosure
use UL listed conduits.
OPERATORS
BE PROPERLY GROUNDED!
MUST
Power switch
For power, a minimum of a
dedicated circuit
breaker is needed.
15-Amp
NOTE:
When applying 230V to
operator make sure voltage
switch is flipped to 230V
position.
NOTE: To use the 120VAC
accessory outlet, connect white
wire from the outlet to neutral.
Only when using 120VAC as the
power source.