ALLNIC AUDIO H-6500 Скачать руководство пользователя страница 8

 

B.

 

POWER CONNECTIONS  

  

The H-6500 power supply uses a standard three prong male IEC connection for AC input 

(See Figure 1), located on the right-hand side of the rear of the power supply (facing the 

rear). You need to use a power cord with a female three prong IEC connector at one end. 

  

The H-6500 power supply connects to the phono-stage itself using the supplied umbilical 

cable.  Connect  the  units  to  each  other  using  the  provided  umbilical  cable,  with  the 

appropriate screw-on connections to the receptacle labeled “DC Source Input” on the 

rear of the phono-stage and the connection terminal labeled “DC Source Output” on the 

left side of the rear of the power supply (See Figure 1). 

  

The H-6500 power supply you have purchased is set internally for your region, either 

AC 230/240 volt – 60 HZ 

OR

 AC 110/120 volt – 60Hz operation for USA, Canada. 

There is no way to change this to another AC setting.  

  

C.

 

INPUTS  

  
There are two (2) sets of two (2) pairs of single-ended (RCA) inputs (See Figure 2). These 

two pairs are located on the left-hand side of the rear of the phono-stage (facing the 

rear - See Figure 1). Each channel pair of inputs is aligned vertically, with the left channel 

input at the top and the right channel input on the bottom. The two left hand pair of 

inputs (facing the back of the phono-stage) have an “MC” label above the two upper, 

i.e. the left, channel connectors; these are the two input pairs for moving coil cartridges. 

The  two  right-hand  pairs  of  inputs  have  an  “MM”  label  above  the  left  channel 

connectors; these are the two input pairs for moving magnet cartridges.  

  

In each case, for both MC and MM connections the left hand vertically aligned pair of 

connections (again, facing the back of the unit) corresponds to input 1 for the button 

switch on the front panel of the phono-stage, while the right hand vertically aligned pair 

is input 2.  

  
To  the  left  of  the  four  MC  RCA  input  connections  is  a  screw  type  connector.  This 

connector is the ground connection for a ground wire from a cartridge and/or turntable 

if  you  are  using  a  moving  coil  cartridge.  To  the  right  of  the  four  MM  RCA  input 

connections is another screw type connector. This connector is the ground connection 

for a ground wire from a cartridge and/or turntable if you are using a moving magnet 

cartridge (See Figure 2).  

  

When you are facing the front of the H-6500, the two pairs of MC connections are on the 

far right of the unit, with the two MM connections immediately to their left.  

  

The H-6500 has been designed and manufactured to work most synergistically with Allnic 

Audio active phono preamplifiers, line stages, amplifiers and ZL cables.  

Содержание H-6500

Страница 1: ...ALLNIC AUDIO H 6500 PHONO STAGE PREAMPLIFIER OWNER S MANUAL...

Страница 2: ...ation for years to come Please read this entire manual before you connect the H 6500 Phono stage to the other components of your system and the wall outlet Audiomentors Allnic Audio marketing company...

Страница 3: ...ions Inputs Outputs Moving Coil MC Transformer Controls A Note on Phase Impedance 7 8 8 9 9 9 9 INITIAL POWER ON 10 OPERATION 10 CURRENT METERS 11 TUBES 11 SPECIFICATIONS 12 WARRANTY 13 FIGURES 14 Ple...

Страница 4: ...frequencies are attenuated In the treble region for high frequency sounds not to be masked by the noise inherent in moving a stylus over and through a modulated vinyl surface some treble frequencies...

Страница 5: ...ance is less than 13 ohms as a comparative some famous ones are 31 ohms The lower the impedance the more dynamic is the sound reproduction with better bass response and speed But LCR RIAA units have d...

Страница 6: ...oltage of your location If it is not please contact your Allnic Audio dealer We advise that you keep the boxes and other packing materials that your H 6500 came in It will be useful if you sell your H...

Страница 7: ...particularly for those who may want to place the H 6500 or its power supply on after market isolation feet or similar devices Dropping one side of either of the H 6500 units or the whole of either uni...

Страница 8: ...nput on the bottom The two left hand pair of inputs facing the back of the phono stage have an MC label above the two upper i e the left channel connectors these are the two input pairs for moving coi...

Страница 9: ...n indicated on the dB scale You should use identical settings for both transformers to avoid channel imbalance F A NOTE ON PHASE Phase issues generally will result in lack of bass and or focus of the...

Страница 10: ...6500 press in the button switch on the front of the power supply marked with on and off icons see Figure 3 Of course the off position is the reverse pressing the button again so it is returns to the...

Страница 11: ...5842 for that channel is failing If the needle on either meter moves to the right of the parallel lines it means that one or both of the voltage regulator error detector tubes 7233 and 5654 for that c...

Страница 12: ...oltage MM non clipping 20Hz 30mV 100Hz 100mV 1KHz 240mV 10KHz 280mV THD Total Harmonic Distortion Less than 0 17 1KHz Output 1V Output Impedance 430 On off method S N Ratio 86db CCIR 1KHz Tubes 5842 x...

Страница 13: ...s and manufacturing defects for one 1 year from date of purchase The warranty is transferable for the balance of the original purchaser s warranty period provided as stated below no unauthorized repai...

Страница 14: ...14 FIGURES Figure 1 H 6500 Power Supply Rear Panel View Figure 2 H 6500 Phono stage Rear Panel View POWER SUPPLY Fuse See Specifications...

Страница 15: ...15 Figure 3 H 6500 Power Supply Front Panel View Figure 4 H 6500 Phono stage Front Panel View POWER SUPPLY FOR PHONO STAGE...

Страница 16: ...16 Figure 5 H 6500 Chassis Top View MC Transformer Control...