WHAT’S IN THE BOX? 

 

  

Please check that the shipping box contains the following:  

  

• 

One (1) Allnic H-6500 phono-stage – in natural aluminum or black, depending on 
your order specification  

• 

One (1) Power Supply for the H-6500 in natural aluminum or black, depending 
on your order specification  

• 

One (1) power umbilical cord 

• 

One (1) IEC type power cord  

• 

One (1) Owner’s Manual  

  
Note:     

1)

 

The H-6500 and its power supply ship with the tubes installed.  

2)

 

The H-6500 power supply will work with most IEC type aftermarket power cords. 
Allnic’s  ZL  Technology  cables  will  function  synergistically  with  the  H-6500.  Of 
course, only you can determine the power cord that works most synergistically 
with the H-6500 in your system.  

3)

 

Be sure the H-6500 power supply unit is labeled for the AC voltage of your 
location. If it is not, please contact your Allnic Audio dealer.  

  
We advise that you keep the boxes and other packing materials that your H-6500 came 

in. It will be useful if you sell your H-6500 or in the unlikely event you need to ship it or 

the power supply for service.  

  

SAFETY  

  

• 

Disconnect the power cord by pulling the plug, not the cable.  

• 

Do not attempt any repairs. Do not remove the units’ chassis covers without specific 
authorization from Allnic Audio. 

• 

Keep the power cords away from heat sources

.

 

• 

Keep the units away from liquids – do not allow any liquid to enter the interior of the 
units.  

• 

When the units are moved from a cold to a warm environment, allow sufficient time 
for any condensation to evaporate in both units before plugging the power supply 
unit into an AC connection.  

• 

Do not attempt any repairs.  

• 

Do not remove the units’ chassis covers without specific authorization from Allnic 
Audio.  

• 

See the notes on “Location, Location, Location”.  

 

 

Содержание H-6500

Страница 1: ...ALLNIC AUDIO H 6500 PHONO STAGE PREAMPLIFIER OWNER S MANUAL...

Страница 2: ...ation for years to come Please read this entire manual before you connect the H 6500 Phono stage to the other components of your system and the wall outlet Audiomentors Allnic Audio marketing company...

Страница 3: ...ions Inputs Outputs Moving Coil MC Transformer Controls A Note on Phase Impedance 7 8 8 9 9 9 9 INITIAL POWER ON 10 OPERATION 10 CURRENT METERS 11 TUBES 11 SPECIFICATIONS 12 WARRANTY 13 FIGURES 14 Ple...

Страница 4: ...frequencies are attenuated In the treble region for high frequency sounds not to be masked by the noise inherent in moving a stylus over and through a modulated vinyl surface some treble frequencies...

Страница 5: ...ance is less than 13 ohms as a comparative some famous ones are 31 ohms The lower the impedance the more dynamic is the sound reproduction with better bass response and speed But LCR RIAA units have d...

Страница 6: ...oltage of your location If it is not please contact your Allnic Audio dealer We advise that you keep the boxes and other packing materials that your H 6500 came in It will be useful if you sell your H...

Страница 7: ...particularly for those who may want to place the H 6500 or its power supply on after market isolation feet or similar devices Dropping one side of either of the H 6500 units or the whole of either uni...

Страница 8: ...nput on the bottom The two left hand pair of inputs facing the back of the phono stage have an MC label above the two upper i e the left channel connectors these are the two input pairs for moving coi...

Страница 9: ...n indicated on the dB scale You should use identical settings for both transformers to avoid channel imbalance F A NOTE ON PHASE Phase issues generally will result in lack of bass and or focus of the...

Страница 10: ...6500 press in the button switch on the front of the power supply marked with on and off icons see Figure 3 Of course the off position is the reverse pressing the button again so it is returns to the...

Страница 11: ...5842 for that channel is failing If the needle on either meter moves to the right of the parallel lines it means that one or both of the voltage regulator error detector tubes 7233 and 5654 for that c...

Страница 12: ...oltage MM non clipping 20Hz 30mV 100Hz 100mV 1KHz 240mV 10KHz 280mV THD Total Harmonic Distortion Less than 0 17 1KHz Output 1V Output Impedance 430 On off method S N Ratio 86db CCIR 1KHz Tubes 5842 x...

Страница 13: ...s and manufacturing defects for one 1 year from date of purchase The warranty is transferable for the balance of the original purchaser s warranty period provided as stated below no unauthorized repai...

Страница 14: ...14 FIGURES Figure 1 H 6500 Power Supply Rear Panel View Figure 2 H 6500 Phono stage Rear Panel View POWER SUPPLY Fuse See Specifications...

Страница 15: ...15 Figure 3 H 6500 Power Supply Front Panel View Figure 4 H 6500 Phono stage Front Panel View POWER SUPPLY FOR PHONO STAGE...

Страница 16: ...16 Figure 5 H 6500 Chassis Top View MC Transformer Control...

Отзывы: