background image

1. PRODUCT DESCRIPTION

Control unit for rolling shutters with integrated radio receiver. BAXS900 can be controlled via radio, via wired buttons and through 
buttons on the front panel. Photocell inputs and safety coast (sensitive edge) are also available.

2.  SAFETY WARNINGS

WARNING! This manual is for qualified personnel only
WARNING! The cover can be removed only by qualified personnel because inside there are live 

parts
WARNING! Before installation, disconnect the device from the power supply, connect the device 

only after having made all the electrical connections

3. DETAIL OF THE FRONT PANEL 

UP COMMAND (ASCENT)
(configurable by DIP 1, DIP 4)

DOWN COMMAND (DESCENT)
(configurable by DIP 2, DIP 4) absence of alarms
(DEAD MAN MODE in presence of alarms)

STOP COMMAND

SAFETY CHECK

SECURITY ERROR (PHOTOCELLS, EDGE)

PRESENCE OF POWER SUPPLY

ACTIVE MOTORS

BAXS900

Control Unit for Rolling Shutters

6-1622623

 /v. 4 15/09/2020

Содержание BAXS900

Страница 1: ...only by qualified personnel because inside there are live parts WARNING Before installation disconnect the device from the power supply connect the device only after having made all the electrical co...

Страница 2: ...erse swap the BROWN and BLACK cables 4 Connect the control buttons OPEN OPEN and CLOSE CLOSE or the key selector type Normally Open N O monostable as shown in the link diagram Fig 2 5 Connect the STOP...

Страница 3: ...ON infinite OFF electronically controlled 2 CLOSE ON impulsive OFF dead man 1 OPEN ON impulsive OFF dead man 1 2 3 4 5 6 7 8 Fig 4 R CO O STANDARD RECIVER T CO O R CO O standard wireless system OPTION...

Страница 4: ...D INPUTS from which it is possible to control the activation of other devices EXAMPLE OF CONNECTION MOLEX R CO O RADIO SYSTEM T CO O R CO O WARNING When using R CO O with plug in connector set the jum...

Страница 5: ...will always be the OPEN ASCENT direction 4 Once the third button CLOSE DESCENT is pressed the control panel will give an extended beep 5 The control panel will give 2 short and close acoustic signals...

Страница 6: ...the control unit to activate the radio memory Pressing the hidden button of an already stored transmitter activates the memory of the radio receiver Pressing the hidden button is equivalent to pressi...

Страница 7: ...ING TIME BAXS900 has as an integrated function the automatic detection of working time by monitoring the motor current By setting DIP 3 to OFF the control unit interrupts the power supply to the engin...

Страница 8: ...ansmitters The closing control is configurable through DIP 2 MAN PRESENT CLOSING IMPULSE CLOSING and through DIP 4 OPEN FUN CTION GO FUNCTION This configuration is binding on all control modes central...

Страница 9: ...S900 is designed according to safety standards and the same include some tests before movement During these tests BAXS900 activates the SAFETY CHECK led on the front panel and performs a series of fla...

Страница 10: ...autotest failure BAXS900 automatic restart Motor ON Blinking Intervention of thermal protection Wait for the control unit to be reactivated Safety Error Motor ON Blinking Autotest circuit damaged Che...

Страница 11: ...Electromagnetic Compatibility Directive 2014 53 UE Radio Equipment Directive This product cannot work independently and is designed to be integrated into a system with other devices It complies with A...

Страница 12: ...m the separate collection for disposal according to the methods provided by the regulations in force in your territory or return the product to the seller when buying a new equivalent product WARNING...