6. Torque adjustment
This procedure needs to be carried out ONLY by the installer and ONLY during the installation of the system. Always bring the gate to a totally closed
position before making any changements for a correct programming. The torque is fix during the slowdowns and does not depend on the position of
the “POWER” trimmer.
Check the torque thrust by using a
dynamometer when the gate is in motion
The torque is too low
It is possible to turn the trimmer POWER to the
direction of the “+” to increase the torque.
The torque is too high
Repeat the measure of
the torque
Repeat the measure-
ment of the torque
It is possible to turn the trimmer POWER to
the direction of the “-” to reduce the torque.
We recommend to adjust the torque before carrying out the learning of the automatism working times
ON
OFF
7. Learning the strokes
This procedure must be carried out ONLY by the installer and ONLY during the installation of the system.
Always bring the gate to a totally closed
position
before making any changements for a correct programming. During the learning phase you must decide if and where the gate needs to start
the slowdown phase.
Press and release
the SEL button
on the card
The accessing to the automatism motion learning menu is shown by
1
Blink
emitted by the flashing light
4
Give an impulse of step-by-step through the button or
the transmitter
7
5
Press and keep pressed
the
MODE button on the card
Release
the MODE button
The learning is cancelled if a safety device (photocell, edge, stop) is activated during the learning phase
Follow these instructions once entered the motion’s learning:
7.1 For applications of motors with and without limit switches (DIP 7 on OFF)
The automation starts to open
When the automation reaches the point where the
opening slowdown is desired, then press and release
the SEL (or MODE) button or give a step-by-step
impulse
6
The automation works with a reduced speed.
When the automation reaches the point where the
opening is desired, then press and release the SEL
(or MODE) button or give a step-by-step impulse
The automatism stops automatically if the
opening limit switch is installed
The automation stops.
Give an impulse of step-by-step through the button or
the transmitter
8
The automation starts to close
10
When the automatism reaches the point where the
closing slowdown is desired, then press and release
the SEL (or MODE) button or give a step-by-step
impulse
9
The automation works with a reduced speed.
When the automatism reaches the point where the
closing is desired, then press and release the SEL (or
MODE) button or give a step-by-step impulse.
The automatism stops automatically if the closing
limit switch is installed
The automation stops.
Dipswitch Position
2
3
1
7
Place the DIPSWITCH 7 on OFF
11
The control unit blinks 3 times
The learning is finished
POWER
+
POWER
+
-
-
Содержание B1EE ERMES2
Страница 15: ...ITA ENG FRA ESP DEU POR 15 16 6 1622158 REV 01 27 07 2012 NOTE...
Страница 17: ...B1EE ERMES2 CONTROL UNIT Programmable control unit for sliding and bascule doors Manual for installation...
Страница 31: ...ITA ENG FRA ESP DEU POR 15 16 6 1622158 REV 01 27 07 2012 REMARKS...
Страница 47: ...ITA ENG FRA ESP DEU POR 15 16 6 1622158 REV 01 27 07 2012 NOTES...
Страница 63: ...ITA ENG FRA ESP DEU POR 15 16 6 1622158 REV 01 27 07 2012 NOTAS...