507277-02
Page 16 of 52
Issue 1621
A95DF1E / 95G1DFE
Table 7
Maximum Allowable Intake or Exhaust Vent Length in Feet
*Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total.
Both Intake and Exhaust must be same pipe size.
Standard Termination at Elevation 0
−
10,000 ft.
Number
Of 90°
Elbows
Used
2" Pipe
2−1/2"
Pipe
3" Pipe
Model
Model
Model
045
070
090
110
045
070
090
110
045
070
090
110
1
61
46
24
n/a
100
80
43
n/a
127
127
108
108
2
56
41
19
95
75
38
122
122
103
103
3
51
36
14
90
70
33
117
117
98
98
4
46
31
n/a
85
65
28
112
112
93
93
5
41
26
80
60
23
107
107
88
88
6
36
21
75
55
18
102
102
83
83
7
31
16
70
50
13
97
97
78
78
8
26
11
65
45
n/a
92
92
73
73
9
21
n/a
60
40
87
87
68
68
10
16
55
35
82
82
63
63
Concentric Termination Elevation 0
−
10,000 ft.
Number
Of 90°
Elbows
Used
2" Pipe
2−1/2"
Pipe
3" Pipe
Model
Model
Model
045
070
090
110
045
070
090
110
045
070
090
110
1
53
38
22
n/a
90
70
39
n/a
111
111
104
104
2
48
33
17
85
65
34
106
106
99
99
3
43
28
12
80
60
29
101
101
94
94
4
38
23
n/a
75
55
24
96
96
89
89
5
33
18
70
50
19
91
91
84
84
6
28
13
65
45
14
86
86
79
79
7
23
n/a
60
40
n/a
81
81
74
74
8
18
55
35
76
76
69
69
9
13
50
30
71
71
64
64
10
n/a
45
25
66
66
59
59
Standard Termination at Elevation 0
−
10,000 ft.
Number
Of 90°
Elbows
Used
2" Pipe
2−1/2"
Pipe
3" Pipe
Model
Model
Model
045
070
090
110
045
070
090
110
045
070
090
110
1
51
36
14
n/a
85
65
28
n/a
107
107
88
88
2
46
31
9
80
60
23
102
102
83
83
3
41
26
4
75
55
18
97
97
78
78
4
36
21
n/a
70
50
13
92
92
73
73
5
31
16
65
45
8
87
87
68
68
6
26
11
60
40
82
82
63
63
7
21
6
55
35
77
77
58
58
8
16
50
30
n/a
72
72
53
53
9
11
n/a
45
25
67
67
48
48
10
6
40
20
62
62
43
40
Maximum Allowable Exhaust Vent Lengths With Furnace Installed in a Closet or
Basement Using Ventilated Attic or Crawl Space for Intake Air in Feet
NOTE:
Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length calculation.
Содержание 95G1DFE
Страница 29: ...507277 02 Page 29 of 52 Issue 1621 Figure 43 Trap Drain Assembly Using 1 2 PVC or 3 4 PVC ...
Страница 35: ...507277 02 Page 35 of 52 Issue 1621 Typical Wiring Diagram Figure 50 For A95DF1E 95G1DFE ...
Страница 46: ...507277 02 Page 46 of 52 Issue 1621 Troubleshooting Heating Sequence of Operation ...
Страница 47: ...507277 02 Page 47 of 52 Issue 1621 Troubleshooting Heating Sequence of Operation continued ...
Страница 48: ...507277 02 Page 48 of 52 Issue 1621 Troubleshooting Cooling Sequence of Operation ...
Страница 49: ...507277 02 Page 49 of 52 Issue 1621 Troubleshooting Continuous Fan Sequence of Operation ...