Elevate Unit

Elevate unit per local clim ate and code requirem ents to

provide clearance above estim ated snowfall level and
ensure adequate drainage of unit.  Use snow stand in
areas where prolonged freezing tem peratures are
encountered.

If conditions or local codes require the unit be attached

to pad or m ounting fram e, tie down bolts should be used
and fastened through knockouts provided in unit base  pan.

Roof Top Installations

Mount on level platform  or fram e 6 inches above roof

surface.  Place unit above a load-bearing wall and isolate
unit and tubing set from  structure.  Arrange supporting
m em bers to adequately support unit and m inim ize
transm ission of vibration to building.  Ensure roof structure
and anchoring m ethod is adequate for location.  Consult
local codes governing rooftop applications.

NOTE:

Unit m ust be level to within ± 2

/

 (± 3/8 in./ft) per

com pressor m anufacturer specifications.

Clearance Requirem ents

W hen installing, allow sufficient space for airflow

clearance, wiring, refrigerant piping, and service.  For
proper airflow, quiet operation and m axim um  efficiency.
Position so water, snow, or ice from  roof or eaves cannot
fall directly on unit.

DO LOCATE THE UNIT:

!

W ith proper clearances on sides and top of unit (a
m inim um  of 12" on the three sides, service side
should be 24" and 48" on top

!

On a solid, level foundation or pad

!

To m inim ize refrigerant line lengths

DO NOT LOCATE THE UNIT:

!

On brick, concrete blocks or unstable surfaces

!

Near clothes dryer exhaust vents

!

Near sleeping area or near windows

!

Under eaves where water, snow or ice can fall
directly on the unit

!

with clearance less than 2 ft. from  a second unit

!

with clearance less than 4 ft. on top of unit

Indoor Coil Piston Selection

The outdoor section m ust be m atched to a factory

approved indoor section.  It is m andatory that the installer
ensure that the correct piston or TXV is installed in the
indoor section.  If necessary rem ove the existing piston and
replace it with the correct piston or TXV.  See  indoor unit
instructions for details of changing the piston or T XV. 
Contact your distributor for accessory piston kits.

The correct piston size is shipped with the outdoor unit,

and also listed in the specification sheet.  Do not use the
piston that com es with the indoor unit, unless it m atches
the one listed on the outdoor unit.

Refrigeration Line Sets

  Use only refrigeration grade copper tubes.  Split

system s m ay be installed with up to 50 feet of line set (no
m ore than 20 feet vertical) without special consideration
(see long line set guide lines).  

        

*  Fittings should be supplied by the installer

.

Do not leave the lines open to the atm osphere for any

period of tim e, m oisture, dirt and bugs m ay contam inate
the lines.

Accum ulation of water and ice in base pan m ay
cause equipm ent dam age.

Содержание 4AC13/14

Страница 1: ...onal state or local codes in any way These instructions must be left with the property owner Manufactured By Allied Air Enterprises LLC A Lennox International Company 215 Metropolitan Drive West Columbia SC 29170 P507043 01 P 507043 01 4AC13 14 SPLIT SYSTEM AIR CONDITIONER INSTALLATION START UP INSTRUCTIONS HOMEOWNERS INFORMATION MANUAL TABLE OF CONTENTS These units are designed for use in residen...

Страница 2: ... approved indoor unit outdoor unit contains system refrigerant charge for operation with indoor unit of the same size when connected by 15 ft of field supplied tubing For proper unit operation check refrigerant charge using charging information located on control box cover IMPORTANT Maximum liquid line size is 3 8 in O D for all residential applications including long lines Outdoor Section Zoning ...

Страница 3: ...ervice side should be 24 and 48 on top On a solid level foundation or pad To minimize refrigerant line lengths DO NOT LOCATE THE UNIT On brick concrete blocks or unstable surfaces Near clothes dryer exhaust vents Near sleeping area or near windows Under eaves where water snow or ice can fall directly on the unit with clearance less than 2 ft from a second unit with clearance less than 4 ft on top ...

Страница 4: ...e a refrigerant leak detector to check all joints The system may also be checked for leaks using a halide torch or pressure and soapy solution After completion of leak check relieve all pressure from system before evacuation Evacuating And Charging Instructions These outdoor units are pre charged at the factory with adequate refrigerant to handle 15 feet of refrigerant tubing 1 Connect the vacuum ...

Страница 5: ...ns shipped with room thermostat Generally the thermostat should not be exposed to sunlight drafts or vibration and should not be mounted on exterior walls Low voltage connections should be in accordance to the wiring diagram Typical Low Voltage Connection Start Up Procedure 1 Close electrical disconnects to energize system 2 Set room thermostat at desired temperature Be sure set point is below ind...

Страница 6: ...low and add charge if superheat is high Units with Indoor TXV Units installed with cooling mode TXV require charging with the subcooling method 1 Operate unit a minimum of 10 minutes before checking charge 2 Measure liquid service valve pressure by attaching an accurate gage to service port Determine saturation temp from T P chart 3 Measure liquid line temperature by attaching an accurate thermist...

Страница 7: ...507043 01 Issue 1222 Page 7 of 8 A C SINGLE PHASE WIRING DIAGRAM ...

Страница 8: ...es can be drawn into coils by movement of the air Clogged condenser coils will lower the efficiency of your unit and could cause damage to the condenser Periodically debris should be brushed from the condenser coils Use a soft bristle brush with light pressure only DO NOT damage or bend condenser coil fins Damaged or bent fins may affect unit operation Painted Surfaces For maximum protection of th...

Отзывы: