THERMOSTAT CONNECTIONS (TB1)
•
DS = DEHUMIDIFICATION SIGNAL
•
W2 = HEAT DEMAND FROM 2ND STAGE T/STAT
•
W1 = HEAT DEMAND FROM 1ST STAGE T/STAT
•
R = CLASS 2 VOLTAGE TO THERMOSTAT
•
G = MANUAL FAN FROM THERMOSTAT
•
C = THERMOSTAT SIGNAL GROUND CONNECTED TO
TRANSFORMER GRD (TR) & CHASSIS GROUND (GRD)
•
Y1 = THERMOSTAT 1ST STAGE COOL SIGNAL
•
Y2 = THERMOSTAT 2ND STAGE COOL SIGNAL
•
O = THERMOSTAT SIGNAL TO HEAT PUMP
•
REVERSING VALVE
•
L = NOT USED
•
DH = NOT USED
3/16” QUICK CONNECT TERMINALS
•
FLAME SENSE SIGNAL
•
HI Cool 24VAC
•
HI HEAT 24VAC
•
LO COOL 24VAC
•
LO HEAT 24VAC
•
PAR
•
PAR
•
COMMON 24VAC
•
1/4” QUICK CONNECT TERMINALS
•
NEUTRALS = 120 NEUTRAL
•
HUM = UNPOWERED NORMALLY OPEN (DRY) CONTACTS
•
LI = 120 VAC INPUT TO CONTROL
•
ACC = 120 VAC OUTPUT TO OPTIONAL ACCESSORY
Figure 58.
Resideo/Honeywell Integrated Furnace Control 103132-xx