Configuration of the camera
Configuration
of
the
camera
Having
this
feature
enabled,
the
current
trigger counter
value
(external
trigger
seen
by
hardware)
will
be
inserted
as
a
32-bit
integer
value
into
any
captured
image.
Setting
the
Reset
flag
to
1
resets
the
trigger counter
to
0:
the
Reset
flag
is
self-cleared.
The
ON_OFF
and
LinePos
fields
are
simply
mirrors
of
the
time
stamp
feature.
Settings
of
these
fields
are
applied
to
all
image
stamp
features.
Additionally
there
is
a
register
for
direct
read
out
of
the
trigger counter
value.
Where to find time stamp, frame counter and trigger counter in the image
Where to find all SIS values in the image
In
the
following
table
you
find
the
position
of
all
SIS
values
(byte
for
byte)
including
the
endianness
of
SIS
values.
Register
Name
Field
Bit
Description
0xF1000620
TRIGGER_COUNTER
Presence_Inq
[0]
Indicates
presence
of
this
feature
(read
only)
Reset
[1]
Reset
trigger
counter
---
[2
to
31] Reserved
0xF1000624
TRGCNT
TriggerCounter
[0
to
31] Trigger
counter
Table 191: Advanced register: Trigger counter
Note
The
four
bytes
of
the
trigger
counter
value
will
be
inserted
as
the
9th
to
12th
byte
of
a
line.
Figure 117: SIS in the image: time stamp, frame counter, trigger counter
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
..
..
.
.
ü
ý
þ
ü
ý
þ
ü
ý
þ
Time stamp (Cycle counter)
Frame counter
Trigger counter
Bytes
Output line
of image