IE048-480 Power Supply Installation Guide
45
Do not operate the power supply on a table, desk, or shelf. Refer to
Figure 7.
Figure 7. Unsupported Table, Desk, or Shelf Installation
Allow for sufficient space for cooling between the power supply and
adjacent objects or devices. Allied Telesis recommends a minimum space
of 25mm between the top and bottom of the power supply and adjacent
objects. Allied Telesis also recommends minimum spaces of 15mm on the
left and right sides when adjacent objects are non-heating (e.g., walls or
cabinets) and 50mm for adjacent heating sources (e.g., switches, routers,
or other power supplies). Refer to Figure 8.
Figure 8. Minimum Spacing Requirements
Minimum
25mm
Minimum
25mm
Minimum
15mm or
50mm
Minimum
15mm or
50mm