background image

613-002833  Rev. A

IE048-480

Industrial AC/DC Power Supply

Installation Guide

Содержание IE048-480

Страница 1: ...613 002833 Rev A IE048 480 Industrial AC DC Power Supply Installation Guide...

Страница 2: ...espective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein i...

Страница 3: ...y with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated i...

Страница 4: ...ironmental Compliance RoHS China RoHS WEEE Safety CAN CSA C22 2 No 107 1 01 CAN CSA C22 2 No 60950 1 EN IEC UL 60950 1 UL 508 Electromagnetic Immunity EN 55024 IEC 61000 3 2 IEC 61000 4 2 level 4 IEC...

Страница 5: ...nter alliedtelesis com library verf gbar sind Declaraciones de seguridad traducidas Importante El indica que las traducciones de la declaraci n de seguridad est n disponibles en las Declaraciones de s...

Страница 6: ...6 I PDF Allied Telesis alliedtelesis com library...

Страница 7: ...Outdoor Enclosure Requirements 36 Grounding Requirements 37 Lightning Protection Requirements 38 Installation Worksheets 39 Chapter 3 Installing the Power Supply 43 Power Supply Orientation 44 Power...

Страница 8: ...Contents 8...

Страница 9: ...45 Figure 9 Wrapping Wire Strands 47 Figure 10 Verifying Wire Installation 47 Figure 11 Installing the Power Supply on a DIN Rail 48 Figure 12 Installing the Ground Wire 51 Figure 13 Installing the A...

Страница 10: ...Figures 10...

Страница 11: ...nectors 27 Table 6 Status LEDs 28 Table 7 Ground Resistivity Recommendations 38 Table 8 Installation Worksheet 1 IE048 480 AC DC Power Supply 40 Table 9 Installation Worksheet 2 Powered Devices 41 Tab...

Страница 12: ...Tables 12...

Страница 13: ...ontains the hardware installation instructions for the IE048 480 Industrial AC DC Power Supply The preface contains the following sections Safety Symbols Used in this Document on page 14 Contacting Al...

Страница 14: ...g conventions Note Notes provide additional information Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data Warning Warnings inform...

Страница 15: ...dise Authorizations RMAs and to contact Allied Telesis technical experts USA and EMEA phone support Select the phone number that best fits your location and customer type Hardware warranty information...

Страница 16: ...Preface 16...

Страница 17: ...ge 18 Hardware Components on page 19 AC Input Connectors on page 22 DC Output Connectors on page 23 TRM Screw for Adjusting the Output DC Voltage on page 24 Remote Control Connector for Turning On or...

Страница 18: ...cket installation Industrial case for hash environments IP20 Operating temperature range of 25 C to 70 C Electromagnetic immunity EMI suitable for industrial applications High efficiency 94 230Vac 150...

Страница 19: ...uide 19 Hardware Components The hardware components on the front panel are identified in Figure 1 Figure 1 Front Panel AC Power Input Connectors Ground Connector Alarm and DC_OK LEDs TRM Screw DC Outp...

Страница 20: ...The hardware components on the top panel are shown in Figure 2 Figure 2 Top Panel The hardware components on the bottom panel are identified in Figure 3 on page 21 Remote Controller Connector DC Outpu...

Страница 21: ...IE048 480 Power Supply Installation Guide 21 Figure 3 Bottom Panel AC Input Connectors Ground Connector...

Страница 22: ...input connectors Warning Never handle live AC power wires Always verify that the AC circuit is powered off before connecting or disconnecting AC power wires from the AC circuit breaker or power suppl...

Страница 23: ...Telesis recommends testing the output voltages on the output connectors with a voltmeter and adjusting the output voltage with the TRM screw if necessary before connecting powered devices to the power...

Страница 24: ...he TRM screw on the front panel Here are the guidelines A voltmeter is required to adjust the DC output power You should verify and adjust output power before connecting powered devices to the power s...

Страница 25: ...e DC output connectors may disrupt network operations E131 Here are the guidelines to using the RC connector The default setting for the DC output connectors is on All four positive and negative DC ou...

Страница 26: ...32 The wire specifications for the Remote Control connector are given in Table 4 Table 4 Wire Specifications for the Remote Control Connector Wire Description Solid Wire AWG 24 to AWG 16 Diameter 0 5...

Страница 27: ...e circuit is closed If the DC output decreases the power supply opens the circuit It remains open until DC output power is restored at which point the power supply automatically closes it again The ex...

Страница 28: ...EDs LED State Description ALARM Off The power supply is powered off or has shut down DC_OK Off ALARM Off The power supply is operating normally DC_OK Green ALARM Red The output voltage is low compared...

Страница 29: ...35 DIN rail clip on its back panel for 35x7 5mm or 35x15mm top hat DIN rails To install the product on a wall install a short length of DIN rail on the wall and then affix the power supply on the rai...

Страница 30: ...up to its maximum DC output power Your installation plans should include determining the power requirements of the individual devices before connecting them to the power supply You need to ensure tha...

Страница 31: ...stallation The chapter contains the following sections Reviewing Safety Precautions on page 32 Safety Precautions When Working with Electricity on page 35 Reviewing Site Requirements on page 36 Instal...

Страница 32: ...the possibility of electric shock disconnect electric power to the product before connecting or disconnecting the LAN cables E1 Warning Do not work on equipment or cables during periods of lightning...

Страница 33: ...supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressin...

Страница 34: ...5 Warning Per NEC section 800 90 all exposed cables service wires or drops entering a building must have primary over voltage protection if they are classified as exposed plants E121 Note Allied Teles...

Страница 35: ...assume that the power is disconnected from a circuit always check the circuit Inspect the work area carefully for possible hazards such as moist floors ungrounded power extension cables frayed power...

Страница 36: ...imum operating temperature capability Allied Telesis recommends the vertical mounting orientation Electromagnetic interference might occur between switches and other devices when multiple switches are...

Страница 37: ...t might be voided Consult Allied Telesis when assistance is needed The enclosure s BTU hour rating must be higher than the total BTU hour values of equipment installed in the enclosure over the expect...

Страница 38: ...stall cable conductors Cable conductors route lightning current over and through the construction without damage toward the grounding electrode system Use appropriate grounding Systems without appropr...

Страница 39: ...is required for outdoor and some indoor installations Installation worksheet 2 Table 9 on page 41 Use this worksheet to record the basics of the powered devices connected to the power supply This inc...

Страница 40: ...40 Table 8 Installation Worksheet 1 IE048 480 AC DC Power Supply Title Description Location Voltage of AC Input Range 90V to 264V Voltage of DC Output Connectors1 Range 45 0V to 55 2V 1 48V default E...

Страница 41: ...el Name PoE Source Device Yes No Maximum Power Consumption Powered Device ___ Model Name PoE Source Device Yes No Maximum Power Consumption Powered Device ___ Model Name PoE Source Device Yes No Maxim...

Страница 42: ...Chapter 2 Beginning the Installation 42...

Страница 43: ...the Power Supply on a DIN Rail on page 48 Connecting the Ground Wire on page 50 Connecting the AC Power Wires on page 52 Adjusting the Voltage on the DC Output Connectors on page 54 Wiring the DC Outp...

Страница 44: ...to top Install the power supply vertically to promote the best possible airflow and cooling Refer to Figure 5 Figure 5 Vertical Installation Do not install the power supply up side down or horizontall...

Страница 45: ...s Allied Telesis recommends a minimum space of 25mm between the top and bottom of the power supply and adjacent objects Allied Telesis also recommends minimum spaces of 15mm on the left and right side...

Страница 46: ...r to Figure 9 on page 47 Table 10 Wire Specifications Connector Wire Description AC DC Input Connectors N Neutral and L Live Solid Wire AWG 20 to AWG 10 Diameter 0 8 to 2 6mm Stranded Wire AWG 20 to A...

Страница 47: ...ually inspect them for exposed wires or loose wire strands Refer to Figure 10 Figure 10 Verifying Wire Installation Warning Check to see if there are any exposed copper strands coming from the install...

Страница 48: ...ngth of DIN rail on the wall Allied Telesis sells packets of five 35x7 5mm DIN rails for wall installations Refer to Figure 4 on page 29 and the Allied Telesis web site for details Warning The device...

Страница 49: ...rify that the DIN rail is now fitted into the top and bottom bracket slots Note Allied Telesis recommends installing DIN rail end clamps to the sides of the device to prevent damage or network traffic...

Страница 50: ...ided Wire insulator stripper not provided To install the ground wire perform the following procedure 1 Prepare an adequate length of wire by stripping 8mm of insulation from one end 2 Loosen the groun...

Страница 51: ...IE048 480 Power Supply Installation Guide 51 Figure 12 Installing the Ground Wire...

Страница 52: ...the wires to the power supply first and then to the AC circuit breaker E135 To attach the AC power wires to the power supply perform the following procedure 1 Verify that the AC circuit breaker is pow...

Страница 53: ...IE048 480 Power Supply Installation Guide 53 Figure 13 Installing the AC Power Wires...

Страница 54: ...dure assumes you have already connected the power supply to an AC power source For instructions refer to Connecting the AC Power Wires on page 52 To verify and adjust the output voltage on the DC outp...

Страница 55: ...sult with a qualified electrician Note The power supply does not support parallel backup or redundancy operation To connect a powered device to the DC Output connectors perform the following procedure...

Страница 56: ...and the negative connector on the power supply to the negative connector on the powered device E137 4 Tighten the screws to secure the wires 5 Visually inspect the wires for exposed wires and loose st...

Страница 57: ...r powering on or off the circuit not provided To wire the Remote Control connector perform the following procedure 1 Prepare adequate lengths of cables by stripping 8mm of insulation from the ends 2 L...

Страница 58: ...rovided Alert device not provided To wire the Power Alert DC_OK connector perform the following procedure 1 Prepare adequate lengths of cables by stripping 8mm of insulation from the ends 2 Loosen the...

Страница 59: ...it for the powered devices to power on and initialize their management software 4 Examine their LEDs to verify that they are operating normally Refer to the devices installation guides for LED descrip...

Страница 60: ...Chapter 3 Installing the Power Supply 60...

Страница 61: ...d The power supply has a technical problem Solutions Try the following Verify that the AC circuit breaker is On Try connecting another device to the AC circuit breaker to verify that it has power Meas...

Страница 62: ...temperature of the site High temperatures can cause a decrease in DC output power Refer to Derating Graph Operating Properties and Ambient Temperature on page 70 Try replacing the power supply Problem...

Страница 63: ...ll the powered devices connected to the device by referring to their installation guides The switch cannot support all the devices if its power budget is less than their total power requirements If th...

Страница 64: ...bleshooting 64 Solutions Try the following Inspect the ALARM LED on the IE048 480 Power Supply If it is on refer to Problem 2 Refer to the switch s installation guide for troubleshooting suggestions f...

Страница 65: ...pendix contains the following sections Physical Specifications on page 66 Power Specifications on page 67 Environmental Specifications on page 69 Derating Graph Operating Properties and Ambient Temper...

Страница 66: ...rheats in an enclosure that was built without taking into account these factors the warranty of the product might be voided Consult Allied Telesis when assistance is needed Table 11 Product Dimensions...

Страница 67: ...yp 230Vac 2 3A typ Frequency 50 60Hz 45 to 66Hz or DC Efficiency 115Vac 92 typ 230Vac 94 typ Power Factor 115Vac 0 98 typ 230Vac 0 93 typ Inrush Current 115Vac 20A typ 1 1 More than 3s to re restart 2...

Страница 68: ...mV Voltage Accuracy Maximum 0 to 70 C 486mV 25 to 70 C 606mV Drift 192mV Start up Time 750ms2 Hold up Time 20ms typ 2 Output Voltage Adjustment Range 45 0 to 55 2Vdc3 Default Output Voltage Setting 48...

Страница 69: ...sted or Nationally Recognized Test Lab enclosure when installed in an indoor Measurement Control or Laboratory environment as specified in UL EN IEC 61010 1 and 61010 2 201 Table 17 Environmental Spec...

Страница 70: ...ance of 10 nominal value The derating properties correspond to a vertically mounted device The operational ambient temperature varies depending on mounting orientation Vertical orientation for the dev...

Страница 71: ...IE048 480 Power Supply Installation Guide 71 Device Dimensions Figure 18 IE048 480 Power Supply Dimensions 124mm 4 88 in 70mm 2 76 in 117mm 4 61 in...

Страница 72: ...Appendix A Technical Specifications 72...