Overview
4
You can configure up to eight AT-3600 Series hubs in a rackmount chassis.
When fully populated with AT-3624T and AT-3624TR hubs, the chassis
creates a single department concentrator with up to 200 ports (8 modules
with 24 network ports each, plus 8 AUI ports).
Figure 2 shows a sample department concentrator using an 8-slot chassis.
You can mount any combination of the following hub models in the same
department concentrator chassis: AT-3606F; AT-3606F/SMA; AT-3606F/
ST, SC, SM; AT-3608; AT-3612T; AT-3612TR; AT-3624T; AT-3624TR;
AT-3624TS; and AT-3624TRS.
Network management software will view the concentrator as a single
logical device. In this configuration the modules perform different
functions:
❑
The top module becomes the
Master
. It downloads software to, and
serves as, the reporting unit for other units in the concentrator. It
also controls management functions.
❑
The module in the slot directly below the Master becomes the
Backup
. It assumes management functions if the Master fails.
❑
All other modules function as
Slaves
. They report management
information to the Master but do not perform any control functions.
Each chassis must contain at least one manageable hub module to enable
network management. This module must occupy the uppermost slot in the
chassis. Because the uppermost manageable hub performs all
management reporting activities, it is referred to as the
Master
. The other
AT-3600 modules in the same chassis (except any Backup module that
may be installed) are called
Slaves
.
Figure 2:
Populated 8-Slot
Chassis
10 BASE-T
RS-232
TERMINAL PORT
POWER
STATUS
MASTER
POWER
FAULT
APPLIQUÉ PORT
3612TR
CentreCOM
TM
IEEE 802.3/ETHERNET 10BASE2
MULTIPORT HUB / REPEATER
with Network Management
LINK
1 2 3 4 5 6 7 8
1
2
3
4
5
6
7
8
9
10
11
12
X
X
X
X
X
X
X
X
X
X
X
X
2
4
12
10
6
8
1
3
11
9
5
7
PORT ACTIVITY
10 BASE T NETWORK PORTS
No Link
Link
Receiving
Indicator OFF
Indicator ON
Indicator FLASHING
PORT STATUS
INDICATOR STATUS
FOIRL
LINK
APPLIQUÉ PORT
RS-232
TERMINAL PORT
POWER
STATUS
MASTER
POWER
FAULT
3612T
CentreCOM
TM
IEEE 802.3/ETHERNET 10BASE2
MULTIPORT HUB / REPEATER
with Network Management
Indicator OFF
PORT ACTIVITY
10 BASE T NETWORK PORTS 1-12
No Link
PORT STATUS
INDICATOR STATUS
MASTER
FAULT
P
O
W
E
R
10
12
9
11
Link
Receiving
Indicator ON
Indicator FLASHING
COLLISION
ACTIVITY
STATUS
6
8
5
7
2
4
1
3
FOIRL
LINK
APPLIQUÉ PORT
RS-232
TERMINAL PORT
POWER
STATUS
MASTER
POWER
FAULT
3612T
CentreCOM
TM
IEEE 802.3/ETHERNET 10BASE2
MULTIPORT HUB / REPEATER
with Network Management
Indicator OFF
PORT ACTIVITY
10 BASE T NETWORK PORTS 1-12
No Link
PORT STATUS
INDICATOR STATUS
MASTER
FAULT
P
O
W
E
R
10
12
9
11
Link
Receiving
Indicator ON
Indicator FLASHING
COLLISION
ACTIVITY
STATUS
6
8
5
7
2
4
1
3
APPLIQUÉ PORT
8
ON LINE
RECEIVE
OFF
ON
TERMINATOR
1
2
3
4
5
6
7
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
FOIRL NETWORK PORTS 1-8
AUI
3608
CentreCOM
TM
IEEE 802.3/ETHERNET 10BASE2
MULTIPORT HUB / REPEATER
with Network Management
RS-232
TERMINAL PORT
POWER
STATUS
MASTER
POWER
FAULT
APPLIQUÉ PORT
8
ON LINE
RECEIVE
OFF
ON
TERMINATOR
1
2
3
4
5
6
7
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
ON LINE
RECEIVE
OFF
ON
TERMINATOR
FOIRL NETWORK PORTS 1-8
AUI
3608
CentreCOM
TM
IEEE 802.3/ETHERNET 10BASE2
MULTIPORT HUB / REPEATER
with Network Management
RS-232
TERMINAL PORT
POWER
STATUS
MASTER
POWER
FAULT
APPLIQUÉ PORT
RS-232
TERMINAL PORT
POWER
STATUS
MASTER
POWER
FAULT
5
6
ON LINE
RECEIVE
TX
RX
ON LINE
RECEIVE
TX
RX
ON LINE
RECEIVE
TX
RX
4
FOIRL NETWORK PORTS 1-6
3
ON LINE
RECEIVE
TX
RX
2
ON LINE
RECEIVE
TX
RX
1
ON LINE
RECEIVE
TX
RX
AUI
3606F
CentreCOM
TM
IEEE 802.3/ETHERNET FOIRL
MULTIPORT HUB / REPEATER
with Network Management
APPLIQUÉ PORT
RS-232
TERMINAL PORT
POWER
STATUS
MASTER
POWER
FAULT
5
6
ON LINE
RECEIVE
TX
RX
ON LINE
RECEIVE
TX
RX
ON LINE
RECEIVE
TX
RX
4
FOIRL NETWORK PORTS 1-6
3
ON LINE
RECEIVE
TX
RX
2
ON LINE
RECEIVE
TX
RX
1
ON LINE
RECEIVE
TX
RX
AUI
3606F
CentreCOM
TM
IEEE 802.3/ETHERNET FOIRL
MULTIPORT HUB / REPEATER
with Network Management
POWER
STATUS
10 BASE-T NETWORK PORTS
1
2
3
4
5
6
X
X
X
X
X
X
7
8
9
10
11
12
X
X
X
X
X
X
13
14
15
16
17
18
X
X
X
X
X
X
19
20
21
22
23
24
X
X
X
X
X
X
NO LINK
INDICATOR OFF
PORT STATUS
INDICATOR STATUS
LINK
INDICATOR ON GREEN
RECEIVING
INDICATOR FLASHING GREEN
PARTITIONED
INDICATOR ON AMBER
COLLISION
INDICATOR FLASHING AMBER
PORT ACTIVITY
3624TRS
CentreCOM
TM
IEEE 802.3/ETHERNET 10
BASE-
T
24 PORT HUB
/REPEA
TER
ACTIVITY
POWER
FAULT
Master
Backup
Department Concentrator Chassis
Slaves