Viewing Statistics
Managing RMON Statistics
Page 175
Configuring RMON History
The
RMON History Page
contains information about samples of data taken from ports. For example, the samples
may include interface definitions or polling periods.
To view RMON history information:
1.
Click
Statistics > RMON History
. The
RMON History Page
opens:
Figure 133:RMON History Page
The
RMON History Page
contains the following fields:
•
History Entry No.
— Displays the history control entry number.
•
Source Interface
— Displays the interface from which the history samples were taken. The possible field
values are:
–
Port
— Specifies the port from which the RMON information was taken.
–
Trunk
— Specifies the trunk from which the RMON information was taken.
•
Sampling Interval
— Indicates in seconds the time period that samplings are taken from the ports. The field
range is 1-3600. The default is 1800 seconds (equal to 30 minutes).
•
Sampling Requested
— Displays the number of samples that the device saves (see
Max. No. of Samples
to Keep
in the
Add RMON History Page
). The field range is 1-65535. The default value is 50.
•
Current Number of Samples
— Displays the current number of samples taken. This number should be
equal to or close to the number of samples requested. If the number of samples exceeds the requested
number, the device discards the older samples until the current number equals the requested amount.
•
Owner
— Displays the RMON station or user that requested the RMON information. The field range is 0-20
characters.