Ethernet Switching Basics

An Ethernet switch interconnects network devices, such as workstations, 
printers, routers, and other Ethernet switches, so that they can 
communicate with each other by sending and receiving Ethernet frames.

Duplex Mode

Duplex mode refers to how an end node receives and transmits data. If an 
end node can receive or transmit data, but not both simultaneously, it is 
operating in what is referred to as half-duplex mode. If an end node can 
both receive and transmit data simultaneously, the end node is operating 
in full-duplex mode. Naturally, an end node capable of operating in full-
duplex can handle data much faster than an end node that can only 
operate in half-duplex mode.

The twisted pair ports on the AT-FS708LE/PoE switch can operate in half- 
or full-duplex mode for 10/100 Mbps. They are IEEE 802.3u-compliant and 
use Auto-Negotiation to set the duplex mode setting for you automatically.

Note

In order for a switch port to successfully Auto-Negotiate its duplex 
mode with a 10 or 100 Mbps end-node, the end-node should also be 
configured for Auto-Negotiation. Otherwise, a duplex mode 
mismatch can occur. A switch port using Auto-Negotiation defaults 
to half-duplex if it detects that the end-node is not using Auto-
Negotiation. This results in a mismatch if the end-node is operating 
at a fixed duplex mode of full-duplex.

Store and

Forward

The AT-FS708LE/PoE switch uses store and forward as the method for 
receiving and transmitting frames. When a Ethernet frame is received on a 
switch port, the switch does not retransmit the frame out the destination 
port until it has received the entire frame and stored the frame in a port 
buffer. It then examines the frame to determine if it is a valid frame. Invalid 
frames, such as fragments or runts, are discarded by the switch. This 
insures that only valid frames are transmitted out the switch ports and that 
damaged frames are not propagated on your network.

Backpressure and

Flow Control

To maintain the orderly movement of data between the end-nodes, an 
Ethernet switch may periodically need to signal an end-node to stop 
sending data. This can occur under several circumstances. For example, if 
two end-nodes are operating at different speeds, the switch, while 
transferring data between the end-nodes, might need to instruct the faster 
end-node to stop transmitting data to allow the slower end-node to catch 
up. An example of this would be when a server operating at 100 Mbps is 
sending data to a workstation operating at only 10 Mbps.

How a switch signals an end-node to stop transmitting data differs 
depending on the duplex mode of the end-node and switch port. A twisted 

Содержание AT-FS708LE/PoE

Страница 1: ...613 002087 Rev A AT FS708LE PoE Fast Ethernet Unmanaged Switch Installation Guide...

Страница 2: ...rks or registered trademarks of their respective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written n...

Страница 3: ...interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instr...

Страница 4: ...adio interference in which case the user may be required to take adequate measures E84 EMC Immunity EN55024 Electrical Safety EN60950 1 TUV UL 60950 1 CULUS RCM CE Mark Translated Safety Statements Im...

Страница 5: ...Forward 15 Backpressure and Flow Control 15 Chapter 2 Installation 17 Reviewing Safety Precautions 18 Selecting a Site for the Switch 20 Planning the Installation 21 Unpacking the Switch 22 Installin...

Страница 6: ...e This manual is the installation and user s guide for the AT FS708LE PoE switch This Preface contains the following sections Safety Symbols Used in this Document on page 7 Contacting Allied Telesis o...

Страница 7: ...is document uses the following conventions Note Notes provide additional information Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of...

Страница 8: ...dise Authorization RMA and contact Allied Telesis technical experts USA and EMEA phone support Select the phone number that best fits your location and customer type Hardware warranty information Lear...

Страница 9: ...9 Chapter 1 Product Description This chapter contains the follows sections Overview on page 10 Key Features on page 13 Power over Ethernet on page 14 Ethernet Switching Basics on page 15...

Страница 10: ...ont panel of the switch x Figure 1 AT FS708LE PoE Front Panel The AT FS708LE PoE switch is designed to be used on a desktop The switch does not require software configuration or management 10 100Base...

Страница 11: ...information refer to Duplex Mode on page 15 Cabling For 10 Mbps operation Category 3 or better unshielded twisted pair cabling is required For 100 Mbps operation Category 5 unshielded twisted pair cab...

Страница 12: ...ystem and Port LEDs LED State Description POE MAX Green The power that the switch is providing to the connected PDs reaches the maximum Off The power that the switch is providing is under the maximum...

Страница 13: ...EE 802 3u compliant on all eight ports Auto MDI MDI X on all eight ports Half or full duplex mode on all eight ports Flow control IEEE 802 3x compliant Storage of up to 1K MAC addresses Wire speed rec...

Страница 14: ...as a resistor or capacitor that the switch can detect over the Ethernet cabling If the resistor or capacitor is present the switch assumes that the device is a PD Power Budgeting The AT FS708LE PoE sw...

Страница 15: ...it detects that the end node is not using Auto Negotiation This results in a mismatch if the end node is operating at a fixed duplex mode of full duplex Store and Forward The AT FS708LE PoE switch use...

Страница 16: ...s ready to receive data again the switch stops forcing collisions This is referred to as backpressure A port operating in full duplex mode uses PAUSE frames as specified in the IEEE 802 3x standard to...

Страница 17: ...Reviewing Safety Precautions on page 18 Selecting a Site for the Switch on page 20 Planning the Installation on page 21 Unpacking the Switch on page 22 Installing the Switch on a Table or Desktop on p...

Страница 18: ...lectric shock disconnect electric power to the product before connecting or disconnecting the cables E1 Warning Do not work on equipment or cables during periods of lightning activity E2 Warning Power...

Страница 19: ...and National Electrical Codes E8 Note The power input must be provided from SELV source only per IEC 60950 Do not connect to a centralized DC battery bank E31 Caution Power to the hub must be sourced...

Страница 20: ...switch and the LEDs on the front of the switch should be easily viewed To allow proper cooling of the switch air flow around the unit and through its vents on the side should not be restricted Do not...

Страница 21: ...d as MDI or MDI X when connected to an end node Consequently you can use a straight through twisted pair cable when connecting any network device to a twisted pair port on the switch A port operating...

Страница 22: ...n You must use the original shipping material if you need to return the unit to Allied Telesis 2 Place the switch on a level secure surface 3 Verify that the following hardware components are included...

Страница 23: ...ing material in a safe place In the event a problem occurs and you need to return the unit use as much of the original shipping material as possible 3 Attach the four self adhesive rubber feet to the...

Страница 24: ...gly into the port on the switch The tab on the connector should lock the connector into place The ports on the switch are auto MDI MDI X You can use a straight through twisted pair cable to connect an...

Страница 25: ...ower connector on the back of the switch as shown in Figure 4 Figure 4 Attach the Power Cord into the Connector 2 Plug the other end of the power cord into a wall outlet See Figure 5 Figure 5 Plug the...

Страница 26: ...26 26 Warning Power cord is used as a disconnection device To de energize equipment disconnect the power cord E3 Caution Only use the AC adapter that is supplied with the unit E85...

Страница 27: ...h Verify that the power outlet or power supply has power by connecting another device to it Try connecting the unit to another power source Try using a different power cord Verify that the voltage fro...

Страница 28: ...Pair Port Connectors on page 30 Physical Specifications Dimensions W x D x H 171 mm x 98 mm x 29 mm 6 7 in x 3 9 in x 1 1 in Weight 0 43 kg 0 95 lbs Environmental Specifications Operating Temperature...

Страница 29: ...allation and User s Guide 29 Safety and Electromagnetic Emissions Certifications EMI FCC Part 15 Class A CISPR 22 Class A EN55022 2006 A1 2007 Class A Immunity EN55024 Electrical Safety UL 60950 1 cUL...

Страница 30: ...d port Figure 6 RJ 45 Connector and Port Pin Layout Table 4 lists the RJ 45 pin signals when a twisted pair port is operating in the MDI configuration Table 5 lists the RJ 45 port pin signals when a t...

Страница 31: ...AT FS708LE PoE Switch Installation and User s Guide 31...

Отзывы: