AT-FS232 and AT-FS232/x Series Installation Guide
27
Warning
When installing this equipment, always ensure that the frame ground
connection is installed first and disconnected last.
16
Figure 15
Connecting the Stripped Wire
6.
Connect the
negative
feed wire to the terminal block marked (
-
).
7.
Connect the
positive
feed wire to the terminal block marked (
+
).
8.
Connect the other end of the wires to the terminal block on the
AT-PWR237 power adapter or approved SELV power source per IEC
60950 (rated minimum 12-50VDC, 0.5A).
Figure 16
Connecting the Stripped Wires to the Optional AT-PWR237 Power Adapter
Note
The optional AT-PWR237 module does not have a terminal for the
ground
feed wire. Connect the ground wire from the bridging converter
to the nearest chassis ground.