background image

Quick Install Guide

5

C613-04038-01 REV D

5.

Install CAM (Optional)

If you purchased a Content Addressable Memory (CAM) module, install it 
now by following the instructions in the 

CAM Quick Install Guide

The 

CAM Quick Install Guide

 can be found on the AT-9800 Series 

Documentation and Tools CD-ROM, or can be downloaded from 
www.alliedtelesyn.co.nz/support/at9800/.

6.

Place the switch in its operating location

If installing the switch in a rack:

Remove the rubber feet

Attach the rack-mounting brackets

Mount the switch in the rack

7.

Apply AC power to the switch (for AC models)

Plug the power cord into the AC power connector on the switch’s rear 
panel. The Fault LED should flash for approximately 10 seconds as the 
switch runs internal tests. 

If the LED continues to flash or remains lit, refer to the

 AT-9800 Series 

Hardware Reference

 for troubleshooting information.

Figure 1: AT-9816GF front panel and rear panel with AC power inlet.

8.

Apply DC power to the switch (for DC models)

Read the 

Safety and Statutory Information

 booklet before connecting a DC 

power supply. A copy of this booklet is included with each switch. It is also 
included on the Documentation and Tools CD-ROM, or can be 
downloaded from www.alliedtelesyn.co.nz/support/at9800/.

CLASS 1

LASER

R.P.S.
INPUT

AC SUPPLY DATA
100-120/200-240

~

HZ

50/60

AMPS

4/2

Input Vdc
+3.3
+5
+12

A Max

13

8
1

COMPACT FLASH

ACTIVITY

AC Power

AT-RPS8000 RPS Connector 

Compact FLASH

STATUS

RESET

FAULT

PWR

RPS

1

9

2

10

3

11

4

12

5

13

6

14

7

15

8

16

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

RS-232

TERMINAL PORT

L /A

GBIC

L /A

GBIC

ASYN0

1000BASE-X GBIC

AT-9816GF

Multi-Layer Gigabit Switch

PORT ACTIVITY

L /A

LINK / FULL DUP

ACTIVITY

LINK / HALF DUP

ACTIVITY

L /A

L /A

ENABLED

DISABLED

FAULT

GBIC

L /A

L /A

GBIC

Содержание AT-9812T

Страница 1: ...AT 9800 SERIES QUICK INSTALL GUIDE...

Страница 2: ...without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damage...

Страница 3: ...ch to a terminal or PC One 19 inch rack mount kit One AT 9800 Series Quick Install Guide One Safety and Statutory Information booklet One AT 9800 Series Documentation and Tools CD ROM which includes t...

Страница 4: ...switch without exceeding maximum cable length limitations See the AT 9800 Series Hardware Reference for cable length specifications Installing the Switch This equipment must be earthed Follow these s...

Страница 5: ...h or remains lit refer to the AT 9800 Series Hardware Reference for troubleshooting information Figure 1 AT 9816GF front panel and rear panel with AC power inlet 8 Apply DC power to the switch for DC...

Страница 6: ...to 0 055 pound force per foot d At the switch connect the positive feed to the positive terminal and the negative feed to the negative terminal Tighten the terminal to between 0 6 and 0 8 Nm 0 041 to...

Страница 7: ...Cs that can be installed in the AT 9816GF for various copper fibre combinations Slide the GBICs into the GBIC slots Press each GBIC firmly into place A range of GBICs have been tested and approved for...

Страница 8: ...ware 3 Check the power supply Ensure that the On Off switch AC models or Run Standby switch DC models is in the On or Run position and that the switch is receiving power Power LED lights green 4 Log i...

Страница 9: ...ous Using the CLI to configure a switch section 2 Enable IP At the CLI enter the command ENABLE IP 3 Assign an IP address to VLAN1 Assign the VLAN1 interface an IP address in the required subnet using...

Страница 10: ...for AT 9800 Series switches LED State Function PWR Power Green The switch is receiving power Fault Red The switch or management software is malfunctioning 1 Flash A switch fan has failed or is operati...

Страница 11: ...formation booklet which includes important safety information and statutory declarations for the AT RPS9000 chassis and AT PWR9000 power unit The AT 9800 Series Hardware Reference which provides detai...

Отзывы: