background image

Quick Install Guide

7

C613-04038-01 REV D

AT-9812TF and AT-9816GF models can be used with AT-RPS8000 RPS 
systems, while AT-9812T and AT-9816GB models can be used with 
AT-RPS9000 systems. 

RPS systems can be purchased separately, contact your authorised Allied 
Telesyn distributor or reseller for more information.

11. Install GBICs

Any combination of copper and fibre GBICs can be installed in the 
following AT-9800 Series switches:

AT-9812T

AT-9812TF

AT-9816GB 

For the AT-9816GF, up to fourteen 1000BASE-T GBICs can be installed. The 
actual number depends on the number of fibre GBICs also installed. 
Table 1 on page -7 lists the number of 1000BASE-T GBICs that can be 
installed in the AT-9816GF for various copper/fibre combinations.

 

Slide the GBICs into the GBIC slots. Press each GBIC firmly into place. 

A range of GBICs have been tested and approved for use with AT-9800 Series switches, 
contact your authorised Allied Telesyn distributor or reseller for more information, or 
visit www.alliedtelesyn.co.nz/support/at9800.

RX and TX terminal locations on SC fibre GBIC ports are the reverse of RX and TX 
terminal locations on fixed SC fibre ports. When looking at an SC fibre GBIC from the 
front, the RX terminal is on the left and the TX terminal is on the right.

12. Connect the data cables

Table 1: GBIC configurations for the AT-9816GF.

Number of fibre GBICs installed

Maximum number of 1000BASE-T GBICs that 
can be installed

0

14

1 13 

2 12 

3

11

4 or 5

10

6

9

7

8

8

10 or 11 

5

12 4

13 3 

14

2

15

1

16

0

Содержание AT-9812T

Страница 1: ...AT 9800 SERIES QUICK INSTALL GUIDE...

Страница 2: ...without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damage...

Страница 3: ...ch to a terminal or PC One 19 inch rack mount kit One AT 9800 Series Quick Install Guide One Safety and Statutory Information booklet One AT 9800 Series Documentation and Tools CD ROM which includes t...

Страница 4: ...switch without exceeding maximum cable length limitations See the AT 9800 Series Hardware Reference for cable length specifications Installing the Switch This equipment must be earthed Follow these s...

Страница 5: ...h or remains lit refer to the AT 9800 Series Hardware Reference for troubleshooting information Figure 1 AT 9816GF front panel and rear panel with AC power inlet 8 Apply DC power to the switch for DC...

Страница 6: ...to 0 055 pound force per foot d At the switch connect the positive feed to the positive terminal and the negative feed to the negative terminal Tighten the terminal to between 0 6 and 0 8 Nm 0 041 to...

Страница 7: ...Cs that can be installed in the AT 9816GF for various copper fibre combinations Slide the GBICs into the GBIC slots Press each GBIC firmly into place A range of GBICs have been tested and approved for...

Страница 8: ...ware 3 Check the power supply Ensure that the On Off switch AC models or Run Standby switch DC models is in the On or Run position and that the switch is receiving power Power LED lights green 4 Log i...

Страница 9: ...ous Using the CLI to configure a switch section 2 Enable IP At the CLI enter the command ENABLE IP 3 Assign an IP address to VLAN1 Assign the VLAN1 interface an IP address in the required subnet using...

Страница 10: ...for AT 9800 Series switches LED State Function PWR Power Green The switch is receiving power Fault Red The switch or management software is malfunctioning 1 Flash A switch fan has failed or is operati...

Страница 11: ...formation booklet which includes important safety information and statutory declarations for the AT RPS9000 chassis and AT PWR9000 power unit The AT 9800 Series Hardware Reference which provides detai...

Отзывы: