GS980M Series Installation Guide

61

Plywood Base

If you are installing the switch on a wall with wooden studs, Allied Telesis 
recommends using a plywood base for the device. (A plywood base is not 
required for a concrete wall.) Refer to Figure 24.

Figure 24. Switch on a Wall with a Plywood Base

The plywood base should be mounted to two studs in the wall. The 
recommended minimum dimensions of the plywood base for GS980M 
Series switches are listed here:

Width: 55.9 centimeters (22 inches)

Height: 61.0 centimeters (24 inches) 

Thickness: 2.5 centimeters (1 inch)

Wall Studs

Wall

Plywood Base

Содержание AlliedWare Plus AT-GS980M/52

Страница 1: ...613 002638 Rev B GS980M Series Gigabit Ethernet Switches AlliedWare Plus AT GS980M 52 AT GS980M 52PS Installation Guide...

Страница 2: ...ir respective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided here...

Страница 3: ...use harmful interference in which case the user will be required to correct the interference at his own expense Note Modifications or changes not expressly approved of by the manufacturer or the FCC c...

Страница 4: ...ed into multiple languages in the Translated Safety Statements document at www alliedtelesis com library Remarque Les consignes de s curit portant le symbole sont traduites dans plusieurs langues dans...

Страница 5: ...s 22 Connector Type 22 Speed 22 Duplex Mode 22 Maximum Distance 22 Cable Requirements 22 Automatic MDIX Detection 23 LEDs 23 Power Over Ethernet on the AT GS980M 52PS Switch 26 PoE Standards 26 Powere...

Страница 6: ...Base 63 Installing the Switch on a Plywood Base 64 Installing the Switch on a Concrete Wall 66 Chapter 6 Cabling the Networking Ports and Powering On the Switch 69 Cabling Twisted Pair Ports 70 Guide...

Страница 7: ...Switch 55 Figure 22 Installing the Switch in an Equipment Rack 56 Figure 23 Positioning the Switch on a Wall 58 Figure 24 Switch on a Wall with a Plywood Base 61 Figure 25 Steps to Installing the Swit...

Страница 8: ...Figures 8...

Страница 9: ...LED 33 Table 8 PORT Parameter Format 36 Table 9 Product Dimensions 88 Table 10 Product Weights 88 Table 11 Ventilation Requirements 88 Table 12 Environmental Specifications 89 Table 13 Maximum Power C...

Страница 10: ...Tables 10...

Страница 11: ...is guide contains the installation instructions for the GS980M Series of Gigabit Ethernet switches This preface contains the following sections Document Conventions on page 12 Contacting Allied Telesi...

Страница 12: ...tions Note Notes provide additional information Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data Warning Warnings inform you tha...

Страница 13: ...about RMAs and to contact Allied Telesis technical experts USA and EMEA phone support Select the phone number that best fits your location and customer type Hardware warranty information Learn about...

Страница 14: ...Preface 14...

Страница 15: ...ge 19 10 100 1000Mbps Twisted Pair Ports on page 22 Power Over Ethernet on the AT GS980M 52PS Switch on page 26 SFP Transceiver Ports on page 29 Fault and Power LEDs on page 31 eco friendly Button on...

Страница 16: ...nels of the GS980M Series Switches The rear panels are shown in Figure 2 on page 17 AT GS980M 52PS Switch 48 10 100 1000Mbps Twisted Pair Ports Management Panel AT GS980M 52 Switch Four 100Mbps or 1Gb...

Страница 17: ...GS980M Series Installation Guide 17 Figure 2 Back Panels AC Power Supply Connector AT GS980M 52PS Switch AT GS980M 52 Switch AC Power Supply Connector...

Страница 18: ...Chapter 1 Overview 18 Management Panel Figure 3 identifies the components on the management panel Figure 3 Management Panel USB Port eco friendly Button Console Management Port System LEDs...

Страница 19: ...r speed and duplex mode Port Link Activity L A LEDs Automatic MDIX detection at 10 or 100Mbps 100Mbps or 1Gbps SFP Transceiver Ports The SFP transceiver ports support the following types of transceive...

Страница 20: ...duplex mode LEDs The twisted pair ports on the AT GS980M 52PS Switch have speed activity and PoE status LEDs The management panel has system LEDs for the power supply and USB slot You can use the eco...

Страница 21: ...Management Methods Here are the methods for managing the switches Local management through the Console port Remote Telnet or Secure Shell management Remote HTTP or HTTPS web browser management SNMPv1...

Страница 22: ...ts operating at 1000Mbps can only operate in full duplex mode The twisted pair ports are IEEE 802 3u compliant and use Auto Negotiate to set the duplex mode setting You can disable Auto Negotiation on...

Страница 23: ...igure the MDI MDI X settings manually with the POLARITY command Refer to Table 18 on page 92 for the port pinouts of the twisted pair ports LEDs The twisted pair ports on the AT GS980M 52 Switch have...

Страница 24: ...10 or 100Mbps Off Possible causes of this state are listed here The port has not established a link with another network device The LEDs are turned off To turn on the LEDs use the eco friendly button...

Страница 25: ...r network device The LEDs are turned off To turn on the LEDs use the eco friendly button PoE LED Solid Green The port is delivering power to a powered device Solid Amber The switch has shut down PoE o...

Страница 26: ...devices PD Examples include wireless access points IP telephones webcams and even other Ethernet switches The switch automatically determines whether or not devices connected to its ports are powered...

Страница 27: ...to some ports based on a system called port priorities You can use this mechanism to ensure that powered devices critical to the operations of your network are given preferential treatment by the swi...

Страница 28: ...defines two methods for delivering DC power over twisted pair cable by a switch to powered devices These methods are known as Modes A and B They identify the individual wires that carry the DC power...

Страница 29: ...parately For a list of supported transceivers refer to the product data sheet on the Allied Telesis web site LEDs Each transceiver port has one LED Refer to Figure 6 Figure 6 SFP Transceiver Port LEDs...

Страница 30: ...sted here The SFP transceiver port is empty The SFP transceiver has not established a link with another network device The LEDs are turned off To turn on the LEDs use the eco friendly button Table 5 L...

Страница 31: ...d Power LEDS State Description Fault LED Off The switch is operating normally or is not powered on Flashing Amber The power supply or switch is experiencing a problem such as overheating To troublesho...

Страница 32: ...e LEDs are turned off The low power mode does not interfere with the network operations of the device The management software on the switch has a command that blinks the LEDs so that you can quickly a...

Страница 33: ...rive Update the AlliedWare Plus management software The port is USB2 0 compatible USB Port LED The USB port has one LED shown in Figure 9 Figure 9 USB Port and LED The states of the LEDs are described...

Страница 34: ...ss for local management To establish a local management session with the switch you use the provided management cable to connect a terminal or a personal computer with a terminal emulation program to...

Страница 35: ...e switch Warning Power cord is used as a disconnection device To de energize equipment disconnect the power cord E3 Note The power supply is not field replaceable The switches have one ventilation fan...

Страница 36: ...Here is an example of the PORT parameter It uses the INTERFACE command to enter the Port Interface mode for ports 15 and 17 awplus enable awplus configure terminal awplus config interface port1 0 15...

Страница 37: ...ginning the Installation The chapter contains the following sections Reviewing Safety Precautions on page 38 Installation Options on page 42 Choosing a Site for the Switch on page 43 Unpacking the Swi...

Страница 38: ...1M Laser product Warning Do not stare into the laser beam L2 Warning Do not look directly at the fiber optic ends or inspect the cable ends with an optical lens L6 Warning To prevent electric shock d...

Страница 39: ...must not be blocked and must have free access to the room ambient air for cooling E6 Warning Operating Temperatures This product is designed for a maximum ambient temperature of 50 degrees C E52 Note...

Страница 40: ...ch that a hazardous condition is not created due to uneven mechanical loading E25 Warning The chassis may be heavy and awkward to lift Allied Telesis recommends that you get assistance when mounting t...

Страница 41: ...nected to cabling that is routed outside the building where this device is located E40 Warning This product may have multiple AC power cords installed To de energize this equipment disconnect all powe...

Страница 42: ...ter 2 Beginning the Installation 42 Installation Options Figure 11 illustrates the three installation options Figure 11 Installation Options Tabletop Standard 19 inch equipment rack Wood or concrete w...

Страница 43: ...located near the switch and be easily accessible The site should allow for easy access to the ports on the front of the switch so that you can easily connect and disconnect cables and view the port LE...

Страница 44: ...S980M Switch Shipping Box Note You should retain the original packaging material in case you need to return the unit to Allied Telesis Figure 13 on page 45 lists the items in the accessory kit Contact...

Страница 45: ...pin connectors Sixteen screws for attaching the wall equipment rack brackets to the switch Length 6 0mm 0 2 in Diameter 4 0mm 0 2 in One regional AC power cords Four anchors for concrete walls Length...

Страница 46: ...Chapter 2 Beginning the Installation 46...

Страница 47: ...s and rivet housings from the bumper feet and then the rivets from the housings Refer to Figure 14 Figure 14 Parts of the Bumper Feet To install the chassis on a table perform the following procedure...

Страница 48: ...bumper foot Refer to Figure 15 Figure 15 Inset the Rivet Housing into the Bumper Foot b Place the bumper foot on one of the corner holes in the base of the switch Refer to Figure 16 Figure 16 Place t...

Страница 49: ...the Bumper Foot d Repeat this step to install the remaining bumper feet 6 Turn the switch over and place it on a flat secure desk or table leaving ample space around it for ventilation 7 Go to Chapte...

Страница 50: ...Chapter 3 Installing the Switch on a Table or Desktop 50...

Страница 51: ...This chapter contains the instructions for installing the switch in a standard 19 inch equipment rack The procedures in this chapter are listed here Beginning the Installation on page 52 Removing the...

Страница 52: ...ws included with the switch Cross head screwdriver not provided Four standard equipment rack screws not provided Switch Orientations in the Equipment Rack The switch has two sets of four screw holes o...

Страница 53: ...GS980M Series Installation Guide 53 Figure 19 GS980M Switch Orientations in an Equipment Rack...

Страница 54: ...ice in an equipment rack If they are already installed perform the following procedure to remove them 1 Place the switch upside down on a level secure surface 2 Use a small flat head screwdriver to pr...

Страница 55: ...you have not chosen an orientation for the switch in the equipment rack review Switch Orientations in the Equipment Rack on page 52 3 Attach two brackets to the sides of the switch in the selected pos...

Страница 56: ...Chapter 4 Installing the Switch in an Equipment Rack 56 Figure 22 Installing the Switch in an Equipment Rack 5 Go to Chapter 6 Cabling the Networking Ports and Powering On the Switch on page 69...

Страница 57: ...s chapter are listed here Switch Orientations on a Wall on page 58 Installation Guidelines on page 59 Plywood Base on page 61 Installing a Plywood Base on page 63 Installing the Switch on a Plywood Ba...

Страница 58: ...ll 58 Switch Orientations on a Wall You can install the switch on a wall with the front panel on the left or right as shown in Figure 23 Do not install it with the front panel on the top or bottom Fig...

Страница 59: ...ging the equipment Warning The device should be installed on a wall by a qualified building contractor Serious injury to yourself or others or damage to the equipment may result if it is not properly...

Страница 60: ...ood base not provided for installing the switch on a wall with wooden studs Refer to Plywood Base on page 61 Four screws for attaching the plywood base not provided Caution The supplied screws and anc...

Страница 61: ...s not required for a concrete wall Refer to Figure 24 Figure 24 Switch on a Wall with a Plywood Base The plywood base should be mounted to two studs in the wall The recommended minimum dimensions of t...

Страница 62: ...the distance between the studs in your wall is different than the industry standard You should install the plywood base on the wall and then install the switch on the base Refer to Figure 25 Figure 2...

Страница 63: ...nstructions for the plywood base The installation guidelines are listed here You should use a stud finder to identify the middle of studs and hot electrical wiring in the wall You should attach the ba...

Страница 64: ...for assistance before moving or lifting it to avoid injuring yourself or damaging the equipment Warning The device should be installed on the wall by a qualified building contractor Serious injury to...

Страница 65: ...n the switch on the wall Position it so that the front panel is either on the left or right Refer to Figure 23 on page 58 Do not install it with the front panel facing up or down Leave sufficient spac...

Страница 66: ...switch on a concrete wall perform the following procedure 1 Place the switch in a table 2 Install the four wall equipment rack brackets to the sides of the unit with the sixteen M4x6mm screws include...

Страница 67: ...ew the following guidelines Prior to drilling set the drill to hammer and rotation mode The modes break up the concrete and clean out the hole Allied Telesis recommends cleaning out the holes with a b...

Страница 68: ...Chapter 5 Installing the Switch on a Wall 68 Figure 29 Installing the Switch on a Concrete Wall 8 Go to Chapter 6 Cabling the Networking Ports and Powering On the Switch on page 69...

Страница 69: ...e following procedures Cabling Twisted Pair Ports on page 70 Guidelines to Handling SFP Transceivers on page 71 Installing SFP Transceivers on page 72 Powering On the Switch on page 76 Starting a Loca...

Страница 70: ...should lock the connectors into place The default speed setting for the ports is Auto Negotiation This setting is appropriate for ports connected to network devices that also support Auto Negotiation...

Страница 71: ...vers are provided in the documents included with the devices You should install a transceiver before connecting its fiber optic cable Fiber optic transceivers are dust sensitive Always keep the plug i...

Страница 72: ...rocedure To install transceivers perform the following procedure 1 Select a port for the transceiver 2 If the port has a dust cover remove it Refer to Figure 30 Figure 30 Removing the Dust Plug from a...

Страница 73: ...nto the port until it clicks into place Note If you are ready to attach the fiber optic cable to the transceiver continue with the next step Otherwise repeat steps 1 to 5 to install the remaining tran...

Страница 74: ...rt the handle should be in the upright position as shown in Figure 33 If the transceiver is in a bottom port the handle should be in the down position Figure 33 Positioning the SFP Handle in the Uprig...

Страница 75: ...GS980M Series Installation Guide 75 Figure 34 Connecting a Fiber Optic Cable to an SFP Transceiver 9 Repeat this procedure to install additional transceivers...

Страница 76: ...is used as a disconnection device To de energize equipment disconnect the power cord E3 Note Pluggable Equipment The socket outlet shall be installed near the equipment and shall be easily accessible...

Страница 77: ...power cord to the AC power connector on the rear panel Refer to Figure 36 Figure 36 Connecting the AC Power Cord 3 Lower the power cord retaining clip to secure the cord to the switch Refer to Figure...

Страница 78: ...ting the Power Cord to an AC Power Source Note The illustration shows a North American power cord Your power cord may be different 5 Wait two minutes for the switch to initialize the management softwa...

Страница 79: ...m the following procedure 1 Connect the RJ 45 end of the management card included with the switch to the Console RS 232 port on the management panel Refer to Figure 39 Figure 39 Connecting the Managem...

Страница 80: ...es respectively Note User names and passwords are case sensitive The local management session starts when the User Exec mode prompt shown in Figure 40 is displayed Figure 40 User Exec Mode Prompt Note...

Страница 81: ...Start a local management session on the switch For instructions refer to Starting a Local Management Session on page 79 2 To display the status of the power supply enter the SHOW SYSTEM ENVIRONMENT c...

Страница 82: ...Chapter 6 Cabling the Networking Ports and Powering On the Switch 82...

Страница 83: ...is within the required levels for your region The power requirements for the switch are listed in Power Specifications on page 90 Problem 2 All of the port LEDs are off even though the ports are conne...

Страница 84: ...t the correct type of fiber optic cabling is being used Verify that the port is connected to the correct fiber optic cable Try connecting another network device to the fiber optic port using a differe...

Страница 85: ...reviewing its documentation or data sheet Verify that you are using the appropriate category of twisted pair cable Refer to Cable Requirements on page 22 Use the management software on the switch to...

Страница 86: ...Chapter 7 Troubleshooting 86...

Страница 87: ...ntains the following sections Physical Specifications on page 88 Environmental Specifications on page 89 Power Specifications on page 90 Certificates on page 91 RJ 45 Twisted Pair Port Pinouts on page...

Страница 88: ...ation Table 11 lists the ventilation requirements Table 9 Product Dimensions AT GS980M 52 4 4 cm x 44 1 cm x 32 3 cm 1 7 in x 17 3 in x 12 7 in AT GS980M 52PS 4 4 cm x 44 1 cm x 35 9 cm 1 7 in x 17 3...

Страница 89: ...he switches Table 12 Environmental Specifications Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature 25 C to 70 C 13 F to 158 F Operating Humidity 5 to 90 noncondensing Storage Humidi...

Страница 90: ...r the switches Input Voltages Table 14 lists the input voltages for the switches Heat Dissipations Table 15 lists the heat dissipations for the switches Table 13 Maximum Power Consumptions AT GS980M 5...

Страница 91: ...EMC EN 55024 EN 55032 Class A EN 61000 3 2 EN 61000 3 3 FCC Part 15 CFR 47 Class A VCCI Class A CISPR 22 Class A ICES 003 Environmental Compliance RoHS WEEE Electrical Safety EN 60950 1 second edition...

Страница 92: ...Twisted Pair Ports Front View Table 17 lists the pin signals at 100Mbps Table 18 lists the pin signals at 1Gbps Table 17 Pin Signals on the RJ 45 Twisted Pair Ports at 10 or 100Mbps Pin MDI Signal MDI...

Страница 93: ...GS980M Series Installation Guide 93 4 Pair 3 5 Pair 3 6 Pair 2 7 Pair 4 8 Pair 4 Table 18 Pin Signals on the RJ 45 Twisted Pair Ports at 1Gbps...

Страница 94: ...Pinouts Table 19 lists the pin signals of the RJ 45 style serial Console port Table 19 Pin Signals of the RJ 45 Style Serial Console Port Pin Signal 1 Looped to pin 8 2 Looped to pin 7 3 Transmit Dat...

Отзывы: