background image

Installation

F232160

16

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation Instructions

To activate lubricator: 

Using a screwdriver or other 

object, tighten activating screw until plastic ring top 
breaks away from screw body. This will ensure proper 
seal of screw and pressure chamber; it is also a safety 
feature to prevent removal of screw.

Mounting: 

All fittings or grease lines should be 

precharged using hand grease gun on first installation 
of Perma lubricators. This step need not be repeated 
when replacing Perma.

Perma lubricators are made with a 1/4 inch NPT. In 
cases where grease fittings have a smaller or larger 
thread size, use standard plumbing adapters.

Perma lubricators require about 30 hours to develop 
operating pressure. In those applications where 
completely uninterrupted lubrication is required, 
Perma should be activated in advance of installation.

 

Figure 10 

PHM537N

PHM537N

Contains Potassium Hydroxide (caustic) 
under pressure. Do not open, puncture or 
remove activating screw. In case of 
accidental breakage and exposure of liquid 
to skin or eyes flush with water for 
15 minutes. If exposed to eyes, contact 
physician after flushing with water. Do not 
expose to temperatures over 150°F (83°C).

W453

CAUTION

Содержание UW50P4

Страница 1: ...mlaundry com Washer Extractors Pocket Hardmount WE 4 WE 5 Control UW50P4 PHM516N PHM516N Part No F232160 September 2002 Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine ...

Страница 2: ......

Страница 3: ... of Contents Introduction 3 Nameplate Location 3 Replacement Parts 3 Customer Service 3 Uncrating 3 Safety Information 5 Important Safety Instructions 5 Installation 7 Familiarization Guide 7 Specifications and Dimensions 8 Dimensional Clearances 9 Machine Foundation 11 Mechanical Installation 12 Drain Connection 12 Water Connection 13 Wiring 13 Perma Automatic Lubricant Injector 15 Visual Safety ...

Страница 4: ... Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 2 F232160 Notes ...

Страница 5: ...stributor Customer Service For technical assistance call any of the following numbers 850 718 1025 850 718 1026 Marianna Florida U S A 920 748 3121 Ripon Wisconsin U S A Uncrating All UW 50 pound washer extractors are carefully tested inspected and adjusted in our plant before crating and are shipped fully assembled Upon uncrating inspect carefully to determine whether there has been any damage in...

Страница 6: ...F232160 4 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...

Страница 7: ...e substances give off vapors that could ignite or explode 5 Under certain conditions hydrogen gas may be produced in a hot water system that has not been used for two weeks or more HYDROGEN GAS IS EXPLOSIVE If the hot water system has not been used for such a period before using a washing machine or combination washer dryer turn on all hot water faucets and let the water flow from each for several...

Страница 8: ...y the manufacturer of the fabric softener or product 18 Keep washer in good condition Bumping or dropping the washer can damage safety features If this occurs have washer checked by a qualified service person 19 Replace worn power cords and or loose plugs 20 Be sure water connections have a shut off valve and that fill hose connections are tight CLOSE the shut off valves at the end of each wash da...

Страница 9: ...her extractor PHM516N 1 Identification Plate 10 Door Lock Switch 2 Door Latch Handle 11 Door Latch Extension Arm 3 Supply Valve Box 12 Rub Rail 4 Supply Dispenser 13 Shell Front 5 Door Handle 14 Door Box 6 Door Box 15 Door Hinge Switch 7 Door Latch 16 Door Hinge Cam 8 Cage Wrap 17 Spray Rinse Tube 9 Side Panel 18 Control Module PHM516N 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 11 18 ...

Страница 10: ... Water Consumption per Cycle 110 gal 416 l Motor Options 2 Speed One 2 Speed Motor 3 HP 208 240 3 Phase 60 Hz 2 24 kW Spray Flush Drain Speed 47 RPM Spray Rinse Drain Speed 465 RPM Extract Speed 465 RPM G Force During Final Extraction 98 Gs 3 Speed One 3 Speed Motor 2 7 HP 208 240 3 Phase 60 Hz 2 01 kW Spray Flush Drain Speed 47 RPM Spray Rinse Drain Speed 265 RPM Extract Speed 525 RPM G Force Dur...

Страница 11: ...m of 24 inches at the rear of the machine and 18 inches at the side for periodic maintenance inspection and adjustment IF two or more washer extractors are to be used they should be spaced at least 18 inches apart so that mounting bolts can be tightened properly and walk through space for maintenance is available NOTE The dimensions shown here are for planning purposes only They are approximate an...

Страница 12: ...r existing floor Pour new concrete in pyramid shape 13 14 1 2 in NPT Steam Inlet Supply connections are inside valve box 7 Compacted Clean Fill Dirt PHM533N C L H C C H C L C L C L 1 2 14 10 7 36 in 915 mm 18 in 455 mm 56 in 1420 mm 63 in 1600 mm 24 in 610 mm 3 4 24 in 610 mm 5 6 7 8 28 in 725 mm 24 in 610 mm 12 in 305 mm 0 5 in 13 mm 40 in Overall 1016 mm 36 in Frame Base 915 mm 16 25 in 415 mm 1...

Страница 13: ...cut a hole through existing concrete floor approximately 5 feet square and excavate to a depth of 36 inches from top of existing floor Refill with 24 inches of WELL compacted clean fill dirt topped with 12 inches of good concrete reinforced with a reinforcing wire and bond existing floor at the sides front and back A bolt locator fixture made of reinforcing rod which may be imbedded in the concret...

Страница 14: ...ase firmly to the floor Check and retighten as necessary Drain Connection The UW50 drainage is by gravity At the rear of the machine on a centerline 15 1 2 inches from the floor is a 3 inch PVC pipe connection In addition a 12 inch length of rubber hose and two hose clamps are packed with the machine to simplify making the connection to the drain line In order to achieve proper drainage for your U...

Страница 15: ... tubing be used in place of the furnished rubber hoses Wiring The UW50 washer extractor is available for 4 wire 208 V or 230 V 60 cycle 3 phase operation only Service breaker should be 30 amps for each machine The control voltage is 115 V The electrical characteristics of each machine are stamped on the specification plate along with the model number and serial number of the machine This informati...

Страница 16: ...rsonal safety and proper operation the machine must be grounded as per state and local codes In the absence of these codes grounding must conform with National Electric Code article 250 95 The ground connection may be to a proven earth ground at the location service panel and or to a grounded metal cold water pipe Do not connect the ground to the neutral N white wire leg at the terminal strip If t...

Страница 17: ...e injector and into the bearing When all of the lubricant has been expelled into the bearing over the life of the particular Perma unit installed it is thrown away and a similar unit installed and activated The Perma unit is non refillable Figure 7 Visual Safety Check As the Perma nears the end of its effective life an internal metal ring becomes clearly visible through the clear plastic cap indic...

Страница 18: ... when replacing Perma Perma lubricators are made with a 1 4 inch NPT In cases where grease fittings have a smaller or larger thread size use standard plumbing adapters Perma lubricators require about 30 hours to develop operating pressure In those applications where completely uninterrupted lubrication is required Perma should be activated in advance of installation Figure 10 PHM537N PHM537N Conta...

Страница 19: ...ernal Supply Connections Figure 11 PHM539N 1 Tube Connections to Supply Dispenser 3 Decal 2 Remove Plug and Bring Wires Through Hole 4 Terminal Strip PHM539N NEUTRAL LINE 1 LINE 2 SUPPLY 1 SUPPLY 2 SUPPLY 3 SUPPLY 4 SUPPLY 5 NEUT TO L 1 OR L 2 115VAC L 1 TO L 2 220VAC NOTE NOT FUSED 1 2 4 3 ...

Страница 20: ...F232160 18 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...

Страница 21: ...te of the valve Tension should not be sufficient to cause the solenoid to hum Some water may be allowed to pass through about 2 or 3 cups per minute since the water level will not be affected NOTE Remember some of the water coming out of the drain line will be due to splash out the overflow not leaking of the drain valve Spray Rinse System The spray rinse system is provided with a vacuum breaker a...

Страница 22: ...tains contact between the two surfaces If contact is lost for any reason such as lint strings getting in between or loosening of the brass collar the seal will leak To reestablish contact between the seal parts it is necessary to move the brass collar toward the rear of the machine This can be done either by loosening the three collar screws and wiggling the collar back on the shaft or by loosenin...

Отзывы: