Mechanical Installation
Use factory rebar base frame. Frame may be placed
during initial floor construction or in a hole dug in
existing floor. Frame can be used for pad mounting. A
form to provide the raised pad will be necessary. Pad
must be 12 inches thick and bonded to existing floor.
NOTE: Mounting on a pad will increase overall
machine height by 12 inches.
1. Cut out a 5 feet x 5 feet x 12 inch thick hole in
concrete floor.
2. Install mounting bolt in the concrete with threads
extending 2 inches above concrete.
3. Raise and level machine 1/2 inch off the floor on
three points by using spacer.
4. Fill the space between machine base and concrete
with machinery grout the full width of all frame
members. Leave a small opening for water
drainage at the rear of machine.
Figure 5
5. After grout has hardened, place the lockwashers
and nuts on the bolts and tighten the base firmly
to the floor. Check and retighten as necessary.
Drain Connection
The UW50 drainage is by gravity. At the rear of the
machine, on a centerline 15-1/2 inches from the floor,
is a 3 inch PVC pipe connection. In addition, a 12 inch
length of rubber hose and two hose clamps are packed
with the machine to simplify making the connection to
the drain line.
In order to achieve proper drainage for your UW50,
refer to
Table 1
. The stub must be at lease 3 inch pipe
with only slight turn for a short distance until large
pipe size is reached.
If proper drain line size is not available or practical, a
surge tank of some sort would be required. A surge
tank would also be used in conjunction with a sump
pump where gravity drainage is not feasible.
Table 1
PHM519N
PHM518N
PHM519N
GROUTING DIAGRAM – APPLY GROUT IN ALL
SHADED AREAS UNDER FRAME MEMBERS.
REMOVE COVER PANELS FOR ACCESS.
35.63 in.
(905 mm)
27.63 in.
(702 mm)
35.75 in.
(908 mm)
4 in. TYP.
(102 mm)
12.13 in.
(308 mm)
11.63 in.
(295 mm)
FRONT
Water and Drain Line Requirements
Number of
UW50s
Pipe Sizes
(Cold and Hot)
Minimum Drain
Sizes
1
3/4 in.
3 in.
2
1-1/4 in.
4 in.
3
1-1/2 in.
5 in.
4
1-1/2 in.
5 in.
5
2 in.
6 in.
6
2 in.
6 in.