8. Using screwdriver, remove two door plugs, and reinstall on
opposite side of door opening.
D317S_SVG
Figure 24
9. Reinstall four hinge attaching screws, removed in Step 1.
D606I_SVG
Figure 25
Wipe Out Inside of Dryer
Before using dryer for the first time, use an all-purpose clean-
er, or a detergent and water solution, and a damp cloth to re-
move shipping dust from inside dryer drum.
Figure 26
Plug In the Dryer
This appliance is to be supplied through a residual current device
(RCD) having a rated residual operating current not exceeding 30
mA.
WARNING
The appliance must not be supplied through an ex-
ternal switching device, such as a timer, or connect-
ed to a circuit that is regularly switched on and off
by a utility.
W943
Electric Dryer
Connect the dryer to an electrical power source. Refer to
Dryer Only - Connect Electrical Plug
for information on con-
necting power cord.
Connect to 30 Amp circuit.
D275I_SVG
3
2
1
4
Figure 27
Gas Dryers
Dryer requires 120 Volt, 60 Hertz electrical supply and comes
equipped with a 3-prong grounding plug. Refer to serial plate for
specific electrical requirements.
NOTE: The wiring diagram is located in the control
hood.
WARNING
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and grounding MUST con-
form with the latest edition of the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local regulations as
might apply. It is the customer’s responsibility to
have the wiring and fuses installed by a qualified
electrician to make sure adequate electrical power is
available to the dryer.
W521