Area
Description
Free Standing/Alcove In-
stallation
Closet Installation
A*
Dryer sides and rear clearance
0 in. [0 mm]
0 in. [0 mm]
B
Dryer top clearance
12.25 in. [305 mm]
12.25 in. [305 mm]
C
Dryer front clearance
Not Applicable
2 in. [51 mm]
D
Exhaust duct clearance to com-
bustible material
2 in. [51 mm]
2 in. [51 mm]
E
Weather hood to ground clear-
ance
12 in. [305 mm]
12 in. [305 mm]
F
Distance from floor or ceiling
to air opening edge
Not Applicable
3 in. [76 mm]
G
Area of centered air openings
in closet door. Louvered door
with equivalent air openings is
acceptable. (Minimum clearan-
ces are shown.)
Not Applicable
40 sq. in./open [260 sq. cm/
open]
H
For new installations, locate
top of wall vent 42 inches
[1067 mm] above floor to make
venting easier to connect.
42 in. [1067 mm]
42 in. [1067 mm]
*
Rear clearance is minimum. 2 inches [51 mm] is recommended for utility connection. 6 inches
[152 mm] is recommended when venting through rear of unit.
Table 1
NOTE: For new installations, it is suggested to locate
top of wall vent 42 inches (106.7 cm) above floor to
make venting easier to connect.
IMPORTANT: In mobile home installations, gas dryers
MUST be permanently attached to the floor at the time
of installation. Order No. 526P3 Dryer Installation Kit
(available at extra cost) for a manufactured (mobile)
home installation. Follow the instructions supplied with
the kit.
Steam Dryers - Connect Water Inlet
Hose
If re-using the washer fill hose filter screen on an already instal-
led washing machine, it must be cleaned before installing the
steam connection. Turn on the water supply faucet and flush the
line for approximately two minutes to remove any foreign materi-
als that could clog the screen in the water valve. This is especial-
ly important when installing your steam dryer in a newly con-
structed or renovated building. Build-up may have occurred dur-
ing construction.
NOTE: Y-connector, extension hose(s) and rubber
washer for Y-Connector are not included with the dryer.
1. Turn off water at shut-off valve.
2. Remove the plain rubber washer and filter screen from the ac-
cessories bag.
3. Disconnect cold-water inlet hose from water supply if wash-
ing machine is connected.
4. Insert rubber washer into Y-connector (both sold separately).
5. Install Y-connector onto cold-water supply (use extension
hose if Y-connector cannot be installed directly on water sup-
ply).
6. Insert filter screen on the faucet end of inlet hose with the
screen facing outward towards the faucet and the rubber
washer on the valve end of the hose.
7. Connect filter screen end of the inlet hose to the Y-Connector.
8. Connect the rubber washer end of inlet hose to the fill valve
on rear of dryer, thread hose coupling finger tight. Then turn
1/4 turn with pliers.
IMPORTANT: Do NOT cross thread or overtighten
couplings. This will cause them to leak.
9. Connect/Reconnect washer inlet hose to the other end of Y-
connector, thread hose coupling finger tight. Then turn 1/4
turn with pliers.
10. If installing new washing machine, connect hose to unit. Re-
fer to washing machine install instructions.