AA –HP410-2011-02                                                Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 

20 

 

No. 

Part    Name 

Quantity 

 

  

 

 

No. 

Part    Name 

Quantity 

Cover 

19 

Axial flow fan 

E-part box ass'y 

20 

Grille 

2.1 

Main controller ass'y 

21 

Motor 

2.2 

Motor capacitor 

22 

Front panel 

2.3 

Compressor capacitor 

23 

Motor bracket ass'y 

2.4 

Relay 

24 

Expansion vessel 

2.5 

Middle connection board ass'y 

25 

Up partition board ass'y 

2.6 

Transformer 

26 

Condenser ass'y 

2.7 

E-part box 

27 

Expansion vessel clap 

Side board 

28 

Side board 

Expansion vessel connection pipe ass'y 

29 

Tube-in-tube heat-exchanger 

water inlet pipe ass'y 

30 

Name Plate 

Water inlet ass'y 

31 

Waterproof net ass'y 

Shield pump ass'y 

32 

Drainage water    pipe ass'y 

Electronic expansion valve    ass'y 

33 

Bracket 

Drain pipe adapter 

34 

Rear net frame 

10 

Left holder 

35 

Rear net 

12 

Terminal installation box 

36 

EEV solenoid 

13 

Rear right clapboard 

37 

4-Ways valve solenoid 

14 

Front right clapboard ass'y 

38 

Small handle 

15 

Base ass'y 

39 

Drain hose 

16 

Partition board ass'y 

40 

Wire controller 

17 

Compressor 

41 

Temperature sensor 

18 

4-way valve ass'y 

42 

Temp sensor 

18.1 

4-way valve 

43 

Temp sensor 

18.2 

Pressure controller 

44 

Temp.sensor ass'y 

 

 

 

 

 

 

46 

Compressor electric heater 

COM P.F

R

S

C

Red

F

A

N

_

L

F

A

N

_

H

4

-W

A

Y

XP8

XS8

RT3

FAN

H_PRO

CT1

N

N

N

N

N

P(8)

P(9)

P(3)

P(4)

P(5)

P(6)

P(7)

P(1)

P(2)

L

P

U

M

P

C

R

A

N

K

F

A

N

-H

F

A

N

-L

4

-W

A

Y

L

N

RT1

RT6

FAN_H

FAN_L

4-WAY

CRANK

4-way

N

CRANK

N

M

PUMP

N

P(1)

P(5)

P(4)

P (2)

P(3)

S1

1

2

3

4

1 2

Note:
1. The forcing switch at the main board inside of
the unit is the open switch for the pump that is
used for operation testing, using by no one but
professional engineer.
2. When wiring the compressor, please pay
attention to the m odel RSJF-35/CN1-A that
installed an external overloadpro tector, which
shown in above broken frame.
For other models without the part of broken
frame, please joint the corresponding terminals
directly, when wiring the comp ressor.

202090590098

2

RSJF-35/CN1-A

H

E

A

T

ON

1 2

1 2

1 2

ON

ON

ON

RSJF-50/CN1-A

RSJF-65/CN1-A

Model selection

(Set before out from factory)

1HP

1.5HP

2HP

Hi-pressu re pro tection

Yellow

Outdoor Temp. Se nsor

Condenser Temp.Sensor

Temp. Sensor at refrigerant

outlet of bushing

Water inlet Temp. Sensor
at bushing

White

Black

Red

Black

Black

Red

H

E

A

T

C

O

M

P

R

E

V

E

R

S

E

P

u

m

p

Transformer

R

e

la

y

1

C

o

m

p

re

s

s

o

r

Brown

Brown

Red

Mid-termina ls
panel

Blue

Brown

Red

Yellow

White

Yellow

4

-w

a

y

H

i-

w

in

d

L

o

-w

in

d

P

u

m

p

R

e

s

e

rv

e

d

C

o

m

p

re

s

s

o

r

h

e

a

ti

n

g

b

a

n

d

Yellow(Green)

Bla ck(Bla ck)

Blue(White)

Brown(Wh ite)

Fan

Fan

Capacity

Fan

Cap acity

The color in bracket is the
fa n motor wire color of 2
horsepower u nit.

White

Blue

Compressor

Blue

White

Yellow/Green

External overload protection

device of compressor

Red(Brown)

Hi-wind

Lo-wind

Blue

Red

Blue

Yellow/green

Boosting pump

4-way valve

Heatin g band

Yello w/Green

Power supply

220V~50Hz

Please apply the attached
electric leakage protection
cable!

Please connect
with the attached
T5 temp. sensor.

N o t e : Th e r ig h t c o m p o n e n t s in t h e f ra m e a re

jo in t e d t o th e c o rr e s p o n d in g in s e rt p a t c h e s in

t h e p in b o a rd ( Jo in te d b e f o r e s h ip m e n t ).

RSJF-28/CN1-A

0.8HP

P le a s e c o n n e c t w i r e
c o n tr o ll e r w ith
a t ta c h e d 5 - c o r e
s h i e ld e d w ir e .

XP10

XS10

T5

Red

Te m p . s e n s o r

i n w a t e r t a n k .

B

la

ck

A B P Q E

R

e

d

Y

e

ll

o

w

B

ro

w

n

W

h

it

e

X T2

P OWER

CN20

S1

TRA NS O UT

CN8

PO WER1

L

N

C N2

C N24

T 5

CN 23

T1

C N22

T 6

CN6

CN7

TRAN S IN

COMOUT

CN 10

CN 9

C OMIN

CT1

QUERY

FOR CE

CN5

RY7

CN2

CN 4

C N21

T p

CN25

T8

CN 27

PR O_L

CN 28

PR O_H

W h i t e

RTp

Temp. S ensor of
compressor air exha ust

Main Control Board

XP5

XS5

Electron
expanding

valve 1

C N1

W h i t e

W h i t e

EEV

Содержание ALLWH3.2kW

Страница 1: ...l 1 Alliance Cycle Heating Domestic Heat Pump Water Heater R410 Technical Manual Applicable Models ALLWH3 2kW R410 ALLWH5 0kW R410 ALLWH7 2kW R410 Alliance reserves the right to discontinue or change...

Страница 2: ...n Unit Foundation Bolt Dimensions 14 6 Service Space 15 7 Wiring Diagrams 15 8 Exploded View 17 9 PCB Explanation 21 Part 3 Installation 22 1 Precautions 23 2 Installation information 24 3 Accessories...

Страница 3: ...HP410 2011 02 Alliance Cycle Heating Domestic Heat Pump Water Heater Technical Manual 3 Part 1 General Information 1 Model Names of Outdoor Units 4 2 External Appearance 4 3 Nomenclature 5 4 Features...

Страница 4: ...ts Model name Dimension mm Net Gross weight kg Power supply ALLWH3 2 KW Width 790 Height 736 Depth 260 54 57 220 240V 1ph 50Hz ALLWH5 0 KW Width 790 Height 736 Depth 260 62 66 220 240V 1ph 50Hz ALLWH7...

Страница 5: ...Household water heating unit Power supply specification code 1 2 3 4 5 6 7 8 9 10 Heating mode code Rated hot water output unit 100 W Water tank volume unit L Other functions code Refrigerant code Wat...

Страница 6: ...ating of water 4 6 Easy operation and automatic control The system can be controlled simply through the wired controller Automatic start up shutdown and automatic defrosting saves extra manual operati...

Страница 7: ...lationship between Outdoor Ambient Temperature and Unit Capacity 10 3 Relationship between Outdoor Ambient Temperature and COP 12 4 Relationship between Outdoor Ambient Temperature and Outlet Water Te...

Страница 8: ...Guangdong Capacity kW 2 88 3 91 5 8 Input kW 1 03 1 35 1 99 Rated current RLA A 4 5 8 9 3 Locked rotor Amp LRA A 19 2 27 4 36 8 Thermal protector INNER INNER INNER Capacitor uF 25 35 50 Refrigerant o...

Страница 9: ...iping Liquid Gas side mm 9 52 9 52 7 94 12 7 Max pipe length water m 5 5 5 Max difference in level of the unit and tank m 3 3 3 Ambient temp 7 43 7 43 7 43 water pipe Diameter water inlet pipe mm DN20...

Страница 10: ...A HP410 2011 02 Alliance Cycle Heating Household Heat Pump Water Heater Technical Manual 10 2 Relationship between Outdoor Ambient Temperature and Unit Capacity Heat Pump Models ALLWH3 2 KW ALLWH5 0 K...

Страница 11: ...AA HP410 2011 02 Alliance Cycle Heating Household Heat Pump Water Heater Technical Manual 11 ALLWH7 2 KW...

Страница 12: ...AA HP410 2011 02 Alliance Cycle Heating Household Heat Pump Water Heater Technical Manual 12 3 Relationship between Outdoor Ambient Temperature and COP Heat Pump Models ALLWH3 2 KW ALLWH5 0 KW...

Страница 13: ...AA HP410 2011 02 Alliance Cycle Heating Household Heat Pump Water Heater Technical Manual 13 ALLWH7 2 KW...

Страница 14: ...and Outlet Water Temperature Note The unit outlet water temperature is under full automatic control and the water tank is the pressure type When hot water is being drawn off cold water will enter the...

Страница 15: ...usehold Heat Pump Water Heater Technical Manual 15 5 Main Unit Foundation Bolt Dimensions B Through hole 12 22 linea rhole A C D MODEL A B C D ALLWH3 2 KW 563 295 100 790 ALLWH5 0 KW 563 295 100 790 A...

Страница 16: ...AA HP410 2011 02 Alliance Cycle Heating Household Heat Pump Water Heater Technical Manual 16 7 Wiring Diagrams ALLWH3 2 ALLWH3 2KW ALLWH5 0 KW ALLWH7 2 KW 1 5HP ALLWH5 0 2HP ALLWH7 2...

Страница 17: ...ing Domestic Heat Pump Water Heater Technical Manual 17 8 Exploded View ALLWH3 2 KW ALLWH5 0 KW 32 32 1 32 2 32 3 32 4 32 5 32 6 7 15 10 27 29 17 18 20 1 2 3 4 5 6 6 1 6 2 9 11 12 13 14 16 19 23 24 25...

Страница 18: ...ear net 1 31 Compressor 1 8 Condenser ass y 1 32 E part box ass y 1 9 Grille 1 32 1 Motor capacitor 1 10 Axial flow fan 1 32 2 Compressor capacitor 1 11 Base ass y 1 32 3 Main control board ass y 1 12...

Страница 19: ...AA HP410 2011 02 Alliance Cycle Heating Domestic Heat Pump Water Heater Technical Manual 19 ALLWH7 2kW...

Страница 20: ...l engineer 2 When wiring the compressor please pay attention to the model RSJF 35 CN1 A that installed an external overloadprotector which shown in above broken frame For other models without the part...

Страница 21: ...AA HP410 2011 02 Alliance Cycle Heating Domestic Heat Pump Water Heater Technical Manual 21 9 PCB explantation...

Страница 22: ...t Pump Water Heater Technical Manual 22 Part 3 Installation 1 Precautions 23 2 Installation information 24 3 Accessories 25 4 System schematic diagram of whole unit 26 5 Electrical wiring 267 6 Outdoo...

Страница 23: ...ds are to be adhered to An independent circuit and single outlet must be used Improper connection or fixing may cause overheating or fire at the connection point Routing of wiring must be properly car...

Страница 24: ...ons Where petrolatum exists Directly exposed to salty air near the coast Where caustic gas e g sulfide exists in the air near a hot spring In areas of excessive vibration e g as can occur in factories...

Страница 25: ...ater tank temperature sensor 1 Water tank temperature check Cautions on remote controller installation Treat controller with care do not mishandle or drop it Before installation operate the remote con...

Страница 26: ...AA HP410 2011 02 Alliance Cycle Heating Domestic Heat Pump Water Heater Technical Manual 26 3 System schematic diagram of whole unit Models ALLWH3 2 KW ALLWH5 0 KW ALLWH7 2 KW...

Страница 27: ...ecification Item Model Power Supply Min wire size mm 2 Metal pipe synthetic resin pipe wire Manual Switch A RCCB Model Size Continuous length 30m Earthing Capacity Fuse ALLWH3 2 KW ALLWH5 0 kW 220 240...

Страница 28: ...ing methods 1 Diameter of the main line a Determine from the power supply specification table according to the sum of horsepower of the unit 2 Diameter of the wiring from the junction box to the power...

Страница 29: ...AA HP410 2011 02 Alliance Cycle Heating Domestic Heat Pump Water Heater Technical Manual 29 5 5 Electrical connection diagram Electrical Wiring diagram for Models ALLWH3 2 KW ALLWH5 0 KW ALLWH7 2 KW...

Страница 30: ...b A distance of no less than 200mm should be maintained between the bottom of the outdoor unit and the ground or bracket for the installation of the duct pipe c Distance between anchor bolt is shown...

Страница 31: ...er etc 7 2 Remarks a The pipe length between host unit and water tank should be a maximum of 5m and the height difference a maximum of 3m If exceeded this could lead to overloaded water pump insuffici...

Страница 32: ...ecting diagram of the water heater No Name Connective pipe specification a Circulating water outlet of main unit DN20 b Circulating water inlet of main unit DN20 c Circulating water outlet of water ta...

Страница 33: ...cklist before the trial operation 34 2 Water Tank water resupplying and Water Pipe and Pump Air Exhaust Artesian Pressure Water Tank 35 3 Wire Controller ALL REMOTE WATER 36 4 Startup Process 36 5 Tri...

Страница 34: ...orrectly 1 3 Pipelines and wiring are correct 1 4 All accessories are installed correctly 1 5 The drainage is smooth without kinks in the pipe 1 6 The thermal insulation is sound 1 7 The earthing wire...

Страница 35: ...the cover on the top of the unit and power the main unit Open the cover on the top of the unit to control the motherboard Power the main unit but do not open the wired controller Start the water pump...

Страница 36: ...own Page up Down Up Lock Mode Alliance Central Heat Pump Water Heater Timing off Clock Timing on Spot Check Temp set Reset Auto Startup Timed Startup Manual Startup Water Temp Set Water Temp Display S...

Страница 37: ...function of the compressor 6 2 Auto Adjustment of Fan Motor If the ambient temperature is high when the unit is operating the fan motor of the unit might be on the low wind operation 6 3 Defrosting in...

Страница 38: ...re protection The circulating pipe between the water tank and the main unit is too small Use the DN 20 pipe The circulating pipe between the water tank and the main unit is too long The length of the...

Страница 39: ...Main Control Board Spot Check Last error protection code Compressor Current TS Temp T6 Temp T5 Temp T4 Temp T3 Temp Wind Speed T2 Temp Operation Mode Normal Display Wire Controller Spot Check Outlet...

Отзывы: