background image

AA –HP410-2011-02                                                Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 

 

 

Alliance Cycle-Heating Domestic   

Heat Pump Water Heater   

R410

 - Technical Manual 

 

 

 

 

 

Applicable Models:   

 

ALLWH3.2kW R410 

          ALLWH5.0kW R410 

    ALLWH7.2kW R410 

 

 

Alliance reserves the right to discontinue, or change at any time, specifications or designs without notices 
and without incurring obligations. 

 

Содержание ALLWH3.2kW

Страница 1: ...l 1 Alliance Cycle Heating Domestic Heat Pump Water Heater R410 Technical Manual Applicable Models ALLWH3 2kW R410 ALLWH5 0kW R410 ALLWH7 2kW R410 Alliance reserves the right to discontinue or change...

Страница 2: ...n Unit Foundation Bolt Dimensions 14 6 Service Space 15 7 Wiring Diagrams 15 8 Exploded View 17 9 PCB Explanation 21 Part 3 Installation 22 1 Precautions 23 2 Installation information 24 3 Accessories...

Страница 3: ...HP410 2011 02 Alliance Cycle Heating Domestic Heat Pump Water Heater Technical Manual 3 Part 1 General Information 1 Model Names of Outdoor Units 4 2 External Appearance 4 3 Nomenclature 5 4 Features...

Страница 4: ...ts Model name Dimension mm Net Gross weight kg Power supply ALLWH3 2 KW Width 790 Height 736 Depth 260 54 57 220 240V 1ph 50Hz ALLWH5 0 KW Width 790 Height 736 Depth 260 62 66 220 240V 1ph 50Hz ALLWH7...

Страница 5: ...Household water heating unit Power supply specification code 1 2 3 4 5 6 7 8 9 10 Heating mode code Rated hot water output unit 100 W Water tank volume unit L Other functions code Refrigerant code Wat...

Страница 6: ...ating of water 4 6 Easy operation and automatic control The system can be controlled simply through the wired controller Automatic start up shutdown and automatic defrosting saves extra manual operati...

Страница 7: ...lationship between Outdoor Ambient Temperature and Unit Capacity 10 3 Relationship between Outdoor Ambient Temperature and COP 12 4 Relationship between Outdoor Ambient Temperature and Outlet Water Te...

Страница 8: ...Guangdong Capacity kW 2 88 3 91 5 8 Input kW 1 03 1 35 1 99 Rated current RLA A 4 5 8 9 3 Locked rotor Amp LRA A 19 2 27 4 36 8 Thermal protector INNER INNER INNER Capacitor uF 25 35 50 Refrigerant o...

Страница 9: ...iping Liquid Gas side mm 9 52 9 52 7 94 12 7 Max pipe length water m 5 5 5 Max difference in level of the unit and tank m 3 3 3 Ambient temp 7 43 7 43 7 43 water pipe Diameter water inlet pipe mm DN20...

Страница 10: ...A HP410 2011 02 Alliance Cycle Heating Household Heat Pump Water Heater Technical Manual 10 2 Relationship between Outdoor Ambient Temperature and Unit Capacity Heat Pump Models ALLWH3 2 KW ALLWH5 0 K...

Страница 11: ...AA HP410 2011 02 Alliance Cycle Heating Household Heat Pump Water Heater Technical Manual 11 ALLWH7 2 KW...

Страница 12: ...AA HP410 2011 02 Alliance Cycle Heating Household Heat Pump Water Heater Technical Manual 12 3 Relationship between Outdoor Ambient Temperature and COP Heat Pump Models ALLWH3 2 KW ALLWH5 0 KW...

Страница 13: ...AA HP410 2011 02 Alliance Cycle Heating Household Heat Pump Water Heater Technical Manual 13 ALLWH7 2 KW...

Страница 14: ...and Outlet Water Temperature Note The unit outlet water temperature is under full automatic control and the water tank is the pressure type When hot water is being drawn off cold water will enter the...

Страница 15: ...usehold Heat Pump Water Heater Technical Manual 15 5 Main Unit Foundation Bolt Dimensions B Through hole 12 22 linea rhole A C D MODEL A B C D ALLWH3 2 KW 563 295 100 790 ALLWH5 0 KW 563 295 100 790 A...

Страница 16: ...AA HP410 2011 02 Alliance Cycle Heating Household Heat Pump Water Heater Technical Manual 16 7 Wiring Diagrams ALLWH3 2 ALLWH3 2KW ALLWH5 0 KW ALLWH7 2 KW 1 5HP ALLWH5 0 2HP ALLWH7 2...

Страница 17: ...ing Domestic Heat Pump Water Heater Technical Manual 17 8 Exploded View ALLWH3 2 KW ALLWH5 0 KW 32 32 1 32 2 32 3 32 4 32 5 32 6 7 15 10 27 29 17 18 20 1 2 3 4 5 6 6 1 6 2 9 11 12 13 14 16 19 23 24 25...

Страница 18: ...ear net 1 31 Compressor 1 8 Condenser ass y 1 32 E part box ass y 1 9 Grille 1 32 1 Motor capacitor 1 10 Axial flow fan 1 32 2 Compressor capacitor 1 11 Base ass y 1 32 3 Main control board ass y 1 12...

Страница 19: ...AA HP410 2011 02 Alliance Cycle Heating Domestic Heat Pump Water Heater Technical Manual 19 ALLWH7 2kW...

Страница 20: ...l engineer 2 When wiring the compressor please pay attention to the model RSJF 35 CN1 A that installed an external overloadprotector which shown in above broken frame For other models without the part...

Страница 21: ...AA HP410 2011 02 Alliance Cycle Heating Domestic Heat Pump Water Heater Technical Manual 21 9 PCB explantation...

Страница 22: ...t Pump Water Heater Technical Manual 22 Part 3 Installation 1 Precautions 23 2 Installation information 24 3 Accessories 25 4 System schematic diagram of whole unit 26 5 Electrical wiring 267 6 Outdoo...

Страница 23: ...ds are to be adhered to An independent circuit and single outlet must be used Improper connection or fixing may cause overheating or fire at the connection point Routing of wiring must be properly car...

Страница 24: ...ons Where petrolatum exists Directly exposed to salty air near the coast Where caustic gas e g sulfide exists in the air near a hot spring In areas of excessive vibration e g as can occur in factories...

Страница 25: ...ater tank temperature sensor 1 Water tank temperature check Cautions on remote controller installation Treat controller with care do not mishandle or drop it Before installation operate the remote con...

Страница 26: ...AA HP410 2011 02 Alliance Cycle Heating Domestic Heat Pump Water Heater Technical Manual 26 3 System schematic diagram of whole unit Models ALLWH3 2 KW ALLWH5 0 KW ALLWH7 2 KW...

Страница 27: ...ecification Item Model Power Supply Min wire size mm 2 Metal pipe synthetic resin pipe wire Manual Switch A RCCB Model Size Continuous length 30m Earthing Capacity Fuse ALLWH3 2 KW ALLWH5 0 kW 220 240...

Страница 28: ...ing methods 1 Diameter of the main line a Determine from the power supply specification table according to the sum of horsepower of the unit 2 Diameter of the wiring from the junction box to the power...

Страница 29: ...AA HP410 2011 02 Alliance Cycle Heating Domestic Heat Pump Water Heater Technical Manual 29 5 5 Electrical connection diagram Electrical Wiring diagram for Models ALLWH3 2 KW ALLWH5 0 KW ALLWH7 2 KW...

Страница 30: ...b A distance of no less than 200mm should be maintained between the bottom of the outdoor unit and the ground or bracket for the installation of the duct pipe c Distance between anchor bolt is shown...

Страница 31: ...er etc 7 2 Remarks a The pipe length between host unit and water tank should be a maximum of 5m and the height difference a maximum of 3m If exceeded this could lead to overloaded water pump insuffici...

Страница 32: ...ecting diagram of the water heater No Name Connective pipe specification a Circulating water outlet of main unit DN20 b Circulating water inlet of main unit DN20 c Circulating water outlet of water ta...

Страница 33: ...cklist before the trial operation 34 2 Water Tank water resupplying and Water Pipe and Pump Air Exhaust Artesian Pressure Water Tank 35 3 Wire Controller ALL REMOTE WATER 36 4 Startup Process 36 5 Tri...

Страница 34: ...orrectly 1 3 Pipelines and wiring are correct 1 4 All accessories are installed correctly 1 5 The drainage is smooth without kinks in the pipe 1 6 The thermal insulation is sound 1 7 The earthing wire...

Страница 35: ...the cover on the top of the unit and power the main unit Open the cover on the top of the unit to control the motherboard Power the main unit but do not open the wired controller Start the water pump...

Страница 36: ...own Page up Down Up Lock Mode Alliance Central Heat Pump Water Heater Timing off Clock Timing on Spot Check Temp set Reset Auto Startup Timed Startup Manual Startup Water Temp Set Water Temp Display S...

Страница 37: ...function of the compressor 6 2 Auto Adjustment of Fan Motor If the ambient temperature is high when the unit is operating the fan motor of the unit might be on the low wind operation 6 3 Defrosting in...

Страница 38: ...re protection The circulating pipe between the water tank and the main unit is too small Use the DN 20 pipe The circulating pipe between the water tank and the main unit is too long The length of the...

Страница 39: ...Main Control Board Spot Check Last error protection code Compressor Current TS Temp T6 Temp T5 Temp T4 Temp T3 Temp Wind Speed T2 Temp Operation Mode Normal Display Wire Controller Spot Check Outlet...

Отзывы: