![Alliance Laundry Systems UY105 PRO Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/alliance-laundry-systems/uy105-pro/uy105-pro_installation-operation-and-maintenance_2901437063.webp)
Chemical Injection Supply System
WARNING
Wear eye and hand protection when handling chemi-
cals; always avoid direct contact with raw chemicals.
Read the manufacturer’s directions for accidental
contact before handling chemicals. Ensure an eye-
rinse facility and an emergency shower are within
easy reach. Check at regular intervals for chemical
leaks.
C365
Undiluted chemical dripping can damage the washerextractor.
Therefore, all chemical supply dispenser pumps should be moun-
ted below the washerextractor’s injection point. All dispenser
tubing should also run below the injection point. Loops do not
prevent drips if these instructions are not followed. Failure to fol-
low these instructions could damage the machine and void the
warranty.
shows a typical chemical injection supply
system.
Chemical Injection Supply System
1.
Injection Point
2.
Chemical Dispenser Pump Outlet
3.
PVC Pipe
Figure 43