Exhaust Requirements
Whenever possible, install the finisher along an
outside wall where duct length can be kept to a
minimum and make-up air can be easily accessed.
Construction must not block the airflow at the rear of
the finisher. Doing so would prevent adequate air
supply to the finisher combustion chamber.
IMPORTANT: Provisions must be made for make-
up air.
IMPORTANT: Do not obstruct flow of combustion
and ventilation air.
IMPORTANT: Using the shortest possible path,
connect the exhaust outlet to an outlet duct. For gas
models, use two separate outlets.
Finisher produces combustible lint. To
reduce the risk of fire, the finisher must be
exhausted to the outdoors.
To reduce the risk of fire and accumulation
of combustible gases, DO NOT exhaust
finisher air into a window well, gas vent,
chimney or enclosed, unventilated area
such as an attic wall, ceiling, crawl space
under a building, or concealed space of a
building.
W679
WARNING
Do not connect vents together. Gas and
ventilation outlets must be separate to
prevent fire.
Insulate all ducts to prevent fire.
W680
WARNING
Exhaust Requirements
UL24*118
UL24*130
UL32*118
UL32*118
Vapor Exhaust
530 cfm
530 cfm
820 cfm
820 cfm
Vapor Exhaust
(Inches of Water Column)
2.4 in.
(60.96 mm)
2.4 in.
(60.96 mm)
2.4 in.
(60.96 mm)
2.4 in.
(60.96 mm)
Exhaust Roll Duct
*Maximum length of exhaust pipe is
14 ft. (4.27 m) and 2 90
o
elbows.
*For ducts longer than 15 ft. (4.57 m),
use next size larger pipe.
4.75 in.
(120 mm)
4.75 in.
(120 mm)
6.25 in.
(120 mm)
6.25 in.
(120 mm)
Table 9