© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming
49
F232101
Programming a Supply Step – Models
with 8 Supplies
On models equipped with 8 supplies, the WE-6
computer is capable of controlling 8 separate supplies,
and up to 31 various combinations of the 8 supplies.
Refer to
Table 8
for a listing of the energized supply
compartments represented by each display code. The
supplies are divided into 2 separate banks of 4 supplies
each. Supply 5 acts as a switching function between
the 2 banks of supplies and is counted as one of the
31 combinations, as it can be programmed alone for
special applications.
The LED display will indicate the combination of
supply compartments that will energize for that
particular supply. For example, when a Supply 3 (first
supply bank, third supply signal) is programmed, the
display reads “S3nncc”, with “nn” representing the
step number and “cc” representing the cycle number.
Supply 3 flushes supply compartment 3. When
Supply 7 (second supply bank, second supply signal)
is selected, the display reads “S7nncc”. Refer to
Table 7
for a full explanation of the 8 available
supplies.
To program a supply in the
first
supply bank, follow
this procedure:
1. The computer must be in Program Mode and the
cycle programming sequence must be ready for
the next step.
2. Press the Supply key. The display will read
“S-nncc”. Press key 1, 2, 3, or 4, whichever
corresponds to the appropriate supply valve to be
turned on. If key 4 is pressed, for example, the
display will read “S4nncc”.
3. Press the Enter key. The display will read
“M---S”. Now enter the time in minutes and
seconds that the supply injection should last.
4. Press the Enter key and go to the next step of the
cycle.
The supplies in the second bank operate in the
following manner:
NOTE: To energize the second bank of supplies,
press the Supply key and key 5.
Supply 5
serves
only
as a switching function between the first and
second supply banks, and is not an actual supply
output.
1. The computer must be in Program Mode, and the
cycle programming sequence must be ready for
the next step.
2. Press the Supply key followed by key 5 to switch
from the first supply bank to the second supply
bank. The display will read “S5nncc”. Now press
key 1, 2, 3, or 4, whichever corresponds to the
appropriate supply valve to be turned on.
Pressing key 1 will energize the first supply
signal of the second supply bank, supply signal 6.
The display will read “S6nncc”. Pressing key 2
will energize the second supply signal of the
second supply bank, supply signal 7. Pressing
key 3 energizes the third supply signal of the
second bank, supply signal 8. Pressing key 4
energizes the fourth supply signal of the second
bank, supply signal 9.