505038
67
SECTION 7
Test Procedures
IMPORTANT: Electrical test procedures in this
service manual are performed by using a Volt-Ohm
meter. Tests can also be performed using a multi-
meter or any other electrical testing equipment with
which the service person is familiar.
55. DRIVE MOTOR (Figure 58)
a. Remove motor and exhaust assembly. See
Paragraph 43.
b. Disconnect motor wire harness at motor
disconnect block.
NOTE: Refer to appropriate wiring diagram when
rewiring motor switch.
NOTE: Drive Motor Resistance
120 Volt
2,460 – 3,100 Ohms
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be reconnected
to ensure that the dryer is properly grounded.
WARNING
W001R1
Figure 58
2
6
4
3
5
1
G
DRIVE
MOTOR
MOTOR AND
EXHAUST
ASSEMBLY
D326SE3A
1
2
4
6
5
3
MOTOR
DISCONNECT
BLOCK
MOTOR
SWITCH