L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft.

3

 [93.1 MJ/m

3

], serv-

ice must be supplied at 10 ± 1.5 inch water column pressure.

For proper operation at altitudes above 3000 feet [915 m] the L.P.
gas valve spud orifice size must be reduced to ensure complete
combustion. Refer to 

Table 4 

.

L.P. Altitude Adjustments

Altitude

Orifice Size

Part No.

feet [m]

No.

inches [mm]

3000 [915]

55

0.0520 [1.32]

58755

8000 [2440]

56

0.0465 [1.18]

D503786

Table 4

 Electric Dryer Only - Connect Electrical

Plug

Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz, 3 or 4
wire electrical supply. Refer to serial plate for specific electrical
requirements.

IMPORTANT: Use only a new U.L. listed No. 10 (copper
wire only) three or four conductor power supply cord
kit rated 240 Volts (minimum) 30 Amperes and labeled
as suitable for use in a clothes dryer.

NOTE: The wiring diagram is located in the control cab-
inet.

WARNING

To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and grounding MUST con-
form with the latest edition of the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local regulations as
might apply. It is the customer’s responsibility to
have the wiring and fuses installed by a qualified
electrician to make sure adequate electrical power is
available to the dryer.

W521

 Earth/Ground Information

This appliance must be properly connected to protective earth/
ground. In the event of malfunction or breakdown, the earth/
ground will reduce the risk of electric shock by providing a path
of least resistance for electric current.

The cord-kit must be equipped with a cord having an equipment-
earth/ground conductor and an earth/ground plug. The plug must
be plugged into an appropriate outlet that is properly installed and

connected to a protective earth/ground in accordance with all lo-
cal codes and ordinances.

WARNING

Improper connection of the equipment earth/ground
conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if
you are in doubt as to whether the dryer is properly
connected to a protective earth/ground.

W886

Do not modify the plug provided with the cord-kit - if it will not
fit the outlet, have a proper outlet installed by a qualified electri-
cian.

The dryer has its own terminal block that must be connected to a
separate branch, 60 Hertz, single phase circuit, AC (alternating
current) circuit, fused at 30 Amperes (the circuit must be fused on
both sides of the line). Electrical service for the dryer should be
of maximum rated voltage (208 or 240 Volt, depending on heat-
ing element) listed on the serial plate. Do not connect dryer to
110, 115, or 120 Volt circuit.

Heating elements are available for field installation in dryers
which are to be connected to electrical service of different volt-
age than that listed on serial plate, such as 208 Volt.

NOTE: Branch circuit wire size requirements to laundry
room outlet are shown in table below.

Wire Length

Wire

Less than 15 ft. [4.5 m]

Listed No. 10 AWG Copper
wire only

Longer than 15 ft. [4.5 m]

Listed No. 8 AWG Copper
wire only

Table 5

The power cord connection between wall receptacle and dryer
terminal block IS NOT supplied with dryer. Type of power cord
and gauge of wire must conform to local codes.

 Connecting Power Cord with Three-Wire Plug

NOTE: Four-wire cord is required for new branch-cir-
cuit installations, mobile homes or where codes do not
permit grounding through neutral.

NOTE: The power cord is NOT supplied with the elec-
tric dryer. Type of power cord and gauge of wire must
conform to local codes and instructions. The method
of wiring the dryer is optional and subject to local code
requirements.

NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the serial plate.

Installation

©

 Copyright, Alliance Laundry Systems LLC -

 DO NOT COPY or TRANSMIT

  15

  Part No. D514320ENR5

Содержание Speed Queen DF7000SE

Страница 1: ...ginal Instructions Keep These Instructions for Future Reference CAUTION Read the instructions before using the machine If this machine changes ownership this manual must accompany machine www speedque...

Страница 2: ......

Страница 3: ...user smells gas The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in a prominent location near the dryer for customer use WARNING Installation of unit must b...

Страница 4: ...r or gas fitter This appliance must be installed with a 36 inch 910 mm long flexible gas connector A T Handle type gas shut off valve must be installed in the gas supply line to this appliance This ap...

Страница 5: ...hree Wire Plug 15 Connecting Power Cord with Four Wire Plug 17 Reverse Door if Desired 18 Wipe Out Inside of Dryer 20 Plug In the Dryer 20 Electric Dryer 20 Gas Dryer 20 Recheck Steps 21 Check Heat So...

Страница 6: ...mm D 4 in 102 mm E 15 4 in 391 mm F 26 875 in 683 mm G 4 5 in 114 mm H 0 4 in 10 mm I 8 in 203 mm J 28 in 711 mm K 23 5 in 597 mm NOTE Exhaust openings are 4 inch 102 mm metal ducting With leveling le...

Страница 7: ...102 mm metal ducting With leveling legs turned into base NOTE Gas models cannot be vented out left side of cabinet because of burner housing IMPORTANT The dryer should have sufficient clear ance arou...

Страница 8: ...e of the dryer 7 Plug in the dryer 8 Recheck steps 9 Start and run the dryer in a heat setting to verify dryer is heat ing Position and Level the Dryer 1 Install dryer before washer This allows room f...

Страница 9: ...DRY2500N_SVG 3 2 1 1 Dryer Base 2 Level 3 Leveling Leg Figure 2 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 9 Part No D514320ENR5...

Страница 10: ...oor DRY2641N_SVG H E D C A 3 1 Front View Closet Door DRY2637N_SVG F F 2 G 1 Closet Door 2 Centered Air Openings G 2 Openings minimum 3 Outer Wall of Enclosure Figure 3 Installation Copyright Alliance...

Страница 11: ...e time of installation Order No 526P3 Hold Down Kit availa ble at extra cost for a manufactured mobile home in stallation Follow the instructions supplied with the kit Installation of unit must confor...

Страница 12: ...exhaust duct 2 feet 610 mm from dry er check with dryer running and no load Exhausting dryer in hard to reach locations can be done by installing 521P3 Flexible Metal Vent Kit available as option al...

Страница 13: ...risk of gas leaks fire or explosion The dryer must be connected to the type of gas as shown on nameplate located in the door re cess Use a new flexible stainless steel connector Use pipe joint compoun...

Страница 14: ...or the appliance category in accordance with national installation regulations of the country of destina tion If in doubt contact the dryer distributor or man ufacturer NOTE When connecting to a gas l...

Страница 15: ...es and ordinances WARNING Improper connection of the equipment earth ground conductor can result in a risk of electric shock Check with a qualified electrician or service person if you are in doubt as...

Страница 16: ...rth Ground Neutral 120 240 Volt 60 Hertz AC 1 Phase Service Entrance Switch Box Refer to NOTE above 8 30 Ampere Fuses or Circuit Breaker 9 Neutral Wire 10 Metallic or Non Metallic Sheathed Cable Coppe...

Страница 17: ...inuity of the earth ground connection before plugging the cord into an outlet Use an acceptable indicating device connected to the center earth ground pin of the plug and the green screw on the back o...

Страница 18: ...1 terminal b Black wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the earth ground to neutral wire re moved in Step 3 and attach a...

Страница 19: ...r panel DRY1916N_SVG B A Figure 17 4 Rotate door panel 180 degrees as shown D273P_SVG Figure 18 5 Remove door strike from door liner and reinstall on opposite side DRY1917N_SVG Figure 19 6 Insert line...

Страница 20: ...ion on connecting power cord Connect to 30 Amp Circuit D275I_SVG2 Figure 25 Gas Dryer Dryer requires 120 Volt 60 Hertz electrical supply and comes equipped with a 3 prong earth ground plug Refer to se...

Страница 21: ...hree prong earth ground plug for your protection against shock haz ard and should be plugged directly into a protective earth ground three prong receptacle Do not cut or remove the earth ground prong...

Страница 22: ...arsh roar ing very blue flame indicates too much air Adjust the air shutter as follows a Loosen the air shutter lockscrew b Turn the air shutter to the left to get a luminous yellow tipped flame then...

Страница 23: ...CHECK 3 GAS ONLY Connect Gas Sup ply Pipe Check for Gas Leaks D233I_SVG1 7 Plug In the Dryer Electric D275I_SVG1 Gas D254I_SVG CHECK CHECK 4 ELECTRIC ONLY Connect Electrical Cord D679I_SVG1 8 Recheck...

Отзывы: