7-04-49

Monthly 
Preventative Maintenance Checklist

Machine:

Month:

Operator:

Checks

Observe All Safety Warnings!

1. Each month or after every 200 hours of operation, 

lubricate the bearings. (Refer to page 7 of the 
Preventative Maintenance Guide for lubrication 
specifications).

2. Use the following procedures to determine if the V-belts 

require replacement or adjustment. 

a. Check the V-belt(s) for uneven wear and frayed 

edges.

b. Check for proper belt tension (refer to pages 7 and 8 

of the Preventative Maintenance Guide for 
specifications).

c. Check for proper alignment (refer to the chart on 

page 8 of the Preventative Maintenance Guide).

3. Remove the back panel and check the overflow hose and 

drain hose for leaks.

4. Unlock the hinged lid and check the supply dispenser 

hoses and hose connections.

5. Use the following procedure to clean the inlet hose filter 

screens:

a. Turn the water off and, if necessary, allow the valve 

to cool.

b. Unscrew the inlet hose and remove the filter screen.

c. Clean the filter with soapy water and reinstall it. 

Replace the filter screen if it is worn or damaged.

6. Tighten the motor mounting belts if necessary.

7. Clean the lint from the motor with compressed air.

8. Clean the interior of the washer-extractor, both the 

basket and the shell, by wiping it with a sponge or cloth.

9. Remove any moisture or dust from all electrical 

components with compressed air.

10.Remove the chemical supply components an check for 

residual chemicals. Clean them as needed and re-install 
them.

Laminate this checklist so that it can be re-used.

https://appliancetechmanuals.com

Содержание Pocket Hardmount

Страница 1: ...Preventative Maintenance www comlaundry com Pocket Hardmount Part No 7 04 49 November 2005 https appliancetechmanuals com ...

Страница 2: ...https appliancetechmanuals com ...

Страница 3: ...ay 2 End of the Day 4 Weekly 6 Monthly 7 Quarterly 11 Care of Stainless Steel 13 Daily Preventative Maintenance Checklist 15 Beginning of the Day 15 End of the Day 16 Weekly Preventative Maintenance Checklist 17 Monthly Preventative Maintenance Checklist 18 Quarterly Preventative Maintenance Checklist 19 IMPORTANT Replace all panels that are removed to perform maintenance procedures Do not operate...

Страница 4: ...k of the machine and at the faucets for leaks 2 Inspect the steam hose connections for leaks where applicable 3 Verify that the insulation is intact on all external wires and that all connections are secure If bare wire is evident call a service technician 4 Check the door interlock before starting operation a Attempt to start the machine with the door open The machine should not start with the do...

Страница 5: ...lose and lock the door and start a cycle Attempt to open the door while the cycle is in progress The door should not open If the door lock and interlock are not functioning properly call a service technician 5 If the washer extractor is equipped with a premium Wet Clean module inspect the water recirculation pipe connections to make sure that they are tight and do not leak https appliancetechmanua...

Страница 6: ...eed models only clean the AC drive filter a Remove the external plastic cover b Remove the foam filter from the cover c Wash the filter with warm water and allow it to air dry The filter may also be vacuumed clean 2 Clean the door gasket of residual detergent and all foreign matter https appliancetechmanuals com ...

Страница 7: ...nse and dry all surfaces after cleaning them 5 Leave the loading door open at the end of each day to allow moisture to evaporate NOTE Unload the machine promptly after each completed cycle to prevent moisture buildup Leave the loading door open after each completed cycle to allow moisture to evaporate 6 If the washer extractor is equipped with a premium Wet Clean module clean the water recirculati...

Страница 8: ... an unloaded cycle to fill the washer extractor b Verify that the door and door gasket do not leak c Verify that the drain valve is operating and that the drain system is free from obstruction If water does not leak out during the pre wash segment the drain valve is closed and functioning properly https appliancetechmanuals com ...

Страница 9: ...at 40 C or 1047 1283 SUS at 100 F An SAE 40 rating is also acceptable as long as the CST or SUS values are within the specified ranges b Pump the grease gun slowly permitting only 2 strokes 2 Use the following procedures to determine if the V belt s require replacement or adjustment Call a qualified service technician in either case a Check the V belt s for uneven wear and frayed edges b After dis...

Страница 10: ...n initial run in force of 5 25 pounds should be used to set the belt tension An operating normal force of 3 5 pounds should be used after the washer extractor has operated for a few hours c Verify that the V belts are properly aligned by checking the pulley alignment Place a straightedge across both pulley faces The straightedge should make contact with the pulleys in four places 3 Remove the back...

Страница 11: ... screens a Turn the water off and if necessary allow the valve to cool b Unscrew the inlet hose and remove the filter screen c Clean the filter screen with soapy water and reinstall it Replace the filter screen if it is worn or damaged 6 Tighten the motor mounting bolts if necessary Pin Motor Pulley Motor Spring https appliancetechmanuals com ...

Страница 12: ...8 Clean the interior of the washer extractor both the basket and the shell by wiping it with a sponge or cloth 9 Remove any moisture or dust from all electrical components with compressed air 10 Remove the chemical supply components and check for residual chemicals Clean them as needed and re install them https appliancetechmanuals com ...

Страница 13: ...rly NOTE Disconnect power to the machine before performing the quarterly maintenance procedures 1 If necessary tighten the door hinges and fasteners 2 If necessary tighten the anchor bolts 3 Verify that the drain motor shield is in place and is secure https appliancetechmanuals com ...

Страница 14: ... or with a solvent based paint If rust appears remove it with sandpaper or by chemical means and then paint the affected area with primer or with a solvent based paint 5 When applicable clean the customer supplied steam filter a Turn off the steam supply and allow time for the valve to cool b Unscrew the cap c Remove the element and clean it d Replace the element and the cap Valve Element Cap http...

Страница 15: ...n iron or steel part not made of stainless steel such as a nail or screw Tip Paint all carbon steel parts with a heavy protective coating Stainless steel fasteners should be used whenever possible Remove discoloration or heat tint from overheating by scouring with a powder or by employing special chemical solutions Do not leave sterilizing solutions on stainless steel equipment for prolonged perio...

Страница 16: ... Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 14 7 04 49 https appliancetechmanuals com ...

Страница 17: ...ing operation a Attempt to start the machine with the door open The machine should not start with the door open b Close the door without locking it and attempt to start the machine The machine should not start with the door unlocked c Close and lock the door and start a cycle Attempt to open the door while the cycle is in progress The door should not open 5 If the washer extractor is equipped with...

Страница 18: ...med clean 2 Clean the door gasket of residual detergent and all foreign matter 3 Clean the automatic supply dispenser lid and general area with mild detergent Rinse the dispenser with clean water 4 Clean the machine s top front and side panels with mild detergent Thoroughly rinse and dry all surfaces after cleaning them 5 Leave the loading door open at the end of each day to allow moisture to evap...

Страница 19: ...sher extractor for leaks a Start an unloaded cycle to fill the washer extractor b Verify that the door and door gasket do not leak c Verify that the drain valve is operating and that the drain system is free from obstruction If water does not leak out during the pre wash segment the drain is closed and functioning properly Laminate this checklist so that it can be re used https appliancetechmanual...

Страница 20: ...el and check the overflow hose and drain hose for leaks 4 Unlock the hinged lid and check the supply dispenser hoses and hose connections 5 Use the following procedure to clean the inlet hose filter screens a Turn the water off and if necessary allow the valve to cool b Unscrew the inlet hose and remove the filter screen c Clean the filter with soapy water and reinstall it Replace the filter scree...

Страница 21: ...he anchor bolts 3 Verify that the drain motor shield is in place and is secure 4 Check all painted surfaces for bare metal refer to page 11 of the Preventative Maintenance Guide 5 When applicable clean the customer supplied steam filter a Turn off the steam supply and allow the valve to cool b Unscrew the cap c Remove the element and clean it d Replace the element and the cap Laminate this checkli...

Страница 22: ...https appliancetechmanuals com ...

Отзывы: