40
53264
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To Test Drive Motor:
1. Disconnect wires from motor switch.
NOTE: Refer to appropriate wiring diagram when
rewiring motor switch.
2. Put test meter probes on terminals 4 and 5. Meter
should read approximately one on Ohm scale.
3. Put test meter probes on terminal 4 and motor
frame. Meter should register “no reading” or
infinite.
4. Put test meter probes on terminal 5 and motor
frame. Meter should register “no reading” or
infinite.
5. Put test meter probes on terminals 4 and 6. Meter
should register “no reading” or infinite. Manually
flex the centrifugal switch in motor and meter
should read approximately two on Ohm scale.
6. Put test meter probes on terminals 1 and 2. Meter
should register “no reading.” Manually flex the
centrifugal switch in motor and meter should
read “zero” Ohms.
Figure 30
DRY838S
MOTOR
SWITCH
DRIVE
MOTOR
GROUND
WIRES